LW112 universal transfer switch is mainly suitable for converting electrical control circuits and electrical measuring instruments in circuits with AC 50 or 60Hz, voltage 380V and below, and DC voltage 220V and below. It can also directly control 3-phase AC cage induction motors of 5.5kW and above. It is mainly used in control circuits such as instruments, micromotors, solenoid valves, etc. The new lock function can realize the authorized operation of the product.
Comply with standards: GB/T 14048.5, IEC 60947-5-1.
This article introduces the interest of CHINT/CHINT LW112 (LW12) universal transfer switch products, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT Miniature Circuit Breaker NXB-125G Quota voltage 230V
Introduction: CHINT/CHINT miniature circuit breaker NXB-125G is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection
Product parameters
...
|
|
CHINT/CHINT NXMFLE series residual current action circuit breaker
NXMFLE residual current action circuit breaker series, suitable for AC 50/60Hz, rated working voltage to 400/415V, rated working current from 10A to 400A in the distribution network circuit, its main function is to provide indirect contact protection for personal electric shock with fatal danger, and to ...
|
|
CHINT/CHINT NXCQ contactor type mechanical emergency starter
Product Overview
NXCQ series contactor emergency start device is a product specially designed and developed for fire water supply system, with the function of manual mechanical emergency start fire pump, in line with GB/T50974-2014 "Technical Specification for Fire Water Supply and Fire Hydrant System" for manual mechanical emergency starting.
|
|
CHINT/CHINT HY2 series reverse switch
HY2 series reverse switch (hereinafter referred to as switch) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 380V, rated working current to 20A motor circuit, used as a direct switch on and off a single squirrel cage induction motor, so that it rotates, reverses and stops.
Compliant with standards ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-40/40
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT NP2 series buttons
NP2 series button is suitable for AC 50Hz or 60Hz, rated working voltage to 415V and DC working voltage to 250V in industrial control circuits, as electromagnetic starters, contactors, relays and other electrical circuit control, with indicator light button is also suitable for light signal indication ...
|
|
CHINT/CHINT YBLX-WL Series Travel Switch YBLX-WL/CA12
YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Accord with...
|
|
CHINT/CHINT UVT-X1H undervoltage tripper
UVT-X1H undervoltage tripper is suitable for AC 50Hz, rated voltage 230V in the line, and NBH-63, NBH-40 series circuit breaker matching, when the tripper terminal voltage is reduced to the undervoltage protection range, the tripper action and drive the circuit breaker to automatically break, so as to achieve the undercurrent of the line...
|
|
CHINT/CHINT NB8-40 miniature circuit breaker
NB8-40 miniature circuit breaker is mainly suitable for AC 50Hz, rated voltage to 240V, rated current to 40A in commercial office buildings, residential and general industrial use of terminal distribution lines, to provide overload, short circuit protection, but also under normal circumstances to the line infrequent turnover...
|
|
CHINT/CHINT Terminal Appliance —NU210-40 Surge Protector
NU210-40 is a surge protective device with short circuit protection. Connect to circuits and devices with an AC rated voltage of 230/400V, 50Hz. Able to protect terminal electrical equipment from the impact of induced lightning, it has the ability to protect against indirect lightning and direct lightning effects or other transient overvoltage surges.
|
|
CHINT DZ47-60M plastic case circuit breaker
DZ47-60M plastic shell circuit breaker is suitable for AC 50Hz, rated voltage to 400V, rated current not more than 63A in the distribution line; It can also be applied to distribution lines where the DC voltage does not exceed 110V at one pole, 220V at both poles, and the rated DC current does not exceed 63A. The circuit breaker is in ...
|
|
CHINT/CHINT Terminal Appliance —NH2-125 Disconnector
NH2-125 disconnector is mainly used as the main switch in the terminal combination electrical appliances, suitable for AC 50Hz, rated voltage to 400V in the power distribution and control circuit, can also be used to control motors, low-power electrical appliances and lighting, widely used in industrial and mining enterprises, high-rise buildings, commercial and household ...
|
|
CHINT/CHINT NB8LE-63 residual current action circuit breaker
NB8LE-63 residual current action circuit breaker is mainly suitable for AC 50Hz, rated voltage to 400V, rated current to 63A in commercial office buildings, residential and general industrial terminal distribution lines, to provide overload, short circuit protection and leakage protection for the line, but also in normal conditions ...
|
|
CHINT/CHINT S9 shunt tripper
The S9 shunt trip device (hereinafter referred to as the tripper) is mainly used for matching with NB1 or NBH8 series circuit breakers, and is suitable for long-distance shunt tripping operation in lines with AC 50Hz (or 60Hz) rated voltage to 400V.
Meets the standard: IEC60947-5-1, obtained CE certification.
3.1 Basic ...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/10
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT NBH-125 miniature circuit breaker
NBH-125 plastic shell circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 125A in the line, for overload and short circuit protection, under normal circumstances, as the line of infrequent operation and conversion, can also be used as a disconnection of the line for line and equipment maintenance...
|
|
CHINT/CHINT DZ15 Series Plastic Case Circuit Breaker DZ15-100
DZ15 series plastic shell circuit breaker (hereinafter referred to as circuit breaker) is suitable for AC 50Hz, rated voltage of 380V, rated current to 100A circuit, as power distribution, motor overload and short circuit protection, but also as line infrequent conversion and motor infrequent start.
...
|
|
CHINT/CHINT CJ20 Series AC Contactor CJ20-25
CJ20 series AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz (or 60Hz), rated working voltage to 660V, rated working current to 630A, for long-distance switching and breaking circuits, and can be combined with appropriate thermal overload relays.
|
|
CHINT/CHINT YBLX-WL series travel switch
YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Accord with...
|
|
CHINT/CHINT NBH-63H miniature circuit breaker
NBH-63H miniature circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 63A in the line, for overload and short circuit protection, under normal circumstances, as the line of infrequent operation and conversion, can also be used as a disconnection of the line for line and equipment maintenance of the isolation open...
|
|