Introduction: The Rosemount/Rosemount electromagnetic sensor MS040, MS slurry sensor is a reliable solution for difficult-to-measure applications such as grit, high solids fluids, long fiber slurries, or devices that generate excessive process noise. Designed for difficult-to-measure applications, the MS slurry sensor overcomes common flow signal difficulties to achieve a stable and sensitive flow output.
Features:
It can handle extremely noisy applications and, when combined with the 8782 transmitter, provides a more stable flow output than standard electromagnetic flowmeters
The enhanced signal strength enables more accurate flow measurements, and when combined with the 8782 flow meter, reduces process variability in difficult-to-measure flows
Dual calibration options reduce sensor inventory
Fully welded sensor housings ensure reliable performance in the harshest environments
With the optional lining protector, installation damage and leading edge wear are prevented.
Use a removable, replaceable terminal block to avoid process downtime and enable on-site repairs
Equipped with an optional secondary containment vessel for information on all potential process fluid leaks
The unobstructed design with no moving parts minimizes the need for maintenance and repairs and is ideal for conductive slurry metering
The MS slurry sensor is combined with the 8782 slurry transmitter for optimal performance in noisy applications.
Product parameters
Reference accuracy: ±0.25% and optional ±0.15% accuracy
Tubing Sizes: 3" (80mm) to 36" (900mm)
Lining material options: PTFE, PFA+, polyurethane, neoprene, linolenic natural rubber, hexadiene
Electrode Options: Material: 316L stainless steel, nickel alloy, platinum, tantalum, titanium
Type: Standard, pop-up, flat
A third ground electrode is optional
Flange Options: Connectors: Sliding, Neck Butt Welding, Groove Connection
Ratings: ASME 150 lb. class - 2500, EN-1092 PN10 - PN40, AS2129 Tables D and E, JIS B2220 10K - 40K, AS4087 PN16 - PN35
Material: Carbon steel, 304/304L SST, 316/316L SST
Other flange grades and materials are available upon request
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the Rosemount/Rosemount electromagnetic sensor MS040 product, if you are interested in the Rosemount/Rosemount sensor, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rosemount/Rosemount Electromagnetic Flowmeter 8750W025 Caliber 0.15-8in
Description: The Rosemount/Rosemount Electromagnetic Flowmeter 8750W025, with its reliable, all-welded coil housing and lightweight sensor design (IP68 rating) ensures that the meter is compatible with all utility, water and wastewater applications. Certified for drinking water.
Product Features ...
|
|
Rosemount/Rosemount Electromagnetic Flowmeter Sensor 8705360 1/2-36 in
Description: The Rosemount/Rosemount electromagnetic flowmeter sensor is 8705360, with an all-welded construction that provides an airtight port for moisture and contaminant protection, while the junction box is removable and replaceable for easy field service.
Features:
For maximum protection, ...
|
|
Rosemount/Rosemount Electromagnetic Sensor MS200 Pipeline size 80-900mm
Introduction: The Rosemount/Rosemount electromagnetic sensor MS200, MS slurry sensor is a reliable solution for difficult-to-measure applications such as grit, high-solids fluids, long fiber slurry, or devices that generate excessive process noise. The MS slurry sensor is designed for difficult-to-measure...
|
|
Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381416
Introduction: The Rosemount/Rosemount Liquid Ultrasonic Flow Meter USM381416, a new custody-transfer meter with excellent linearity over the flow range, further reducing product loss and unspecified losses. A new generation of electronics optimizes the operation of the flow meter, and the full-bore design ensures that the flow meter is ...
|
|
The Rosemount/Rosemount Temperature Transmitter 644 outputs 4-20mA
Introduction: Rosemount/Rosemount Temperature Transmitter 644, the Rosemount 644 temperature transmitter is versatile and available using HART®, FOUNDATION™ fieldbus, or PROFIBUS® protocols, with top, field, or rail mounting styles and a variety of enclosure options. Pass...
|
|
Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW030
Description: The Rosemount/Rosemount Thin Plate Vortex Flow Meter 8800DW030 provides a cost-effective, lightweight alternative to flanged vortex flow meters. The compact, space-saving design is versatile and can be installed in any location.
Products...
|
|
Rosemount/Rosemount Flanged Electromagnetic Flowmeter Sensor 8705025
Description: The Rosemount/Rosemount flanged electromagnetic flowmeter sensor 8705025 all-welded construction provides an airtight port for moisture and contaminant protection, while the junction box is removable and replaceable for easy field service.
Features:
In order to achieve maximum ...
|
|
Rosemount/Rosemount In-Line Oxygen Analyzer 6888C Communication Protocol 4-20mA
Introduction: The Rosemount/Rosemount In-Line Oxygen Analyzer 6888C, Rosemount 6888C In-Line Oxygen Analyzer provides continuous, accurate measurement of oxygen in flue gases in hazardous areas. Accurate measurement of the amount of residual oxygen is essential for the combustion reaction, reducing energy costs and improving safety.
|
|
Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381208 Operating pressure range 0-155Bar
Introduction: The Rosemount/Rosemount Two-Channel Liquid Ultrasonic Flow Meter USM381208, two-channel design, field-replaceable sensor, high accuracy and repeatability of measurement results, suitable for verification metering, distribution, leak detection, pipeline balancing, process measurement, and other non-trade transactions.
|
|
Rosemount/Rosemount General Purpose pH/ORP Sensor 389
Introduction: Rosemount/Rosemount Universal pH/ORP Sensor 389, the Rosemount 389 sensor uses a molded Tefzel™ body and Viton™ O-rings to make each sensor extremely difficult to damage and highly resistant to chemicals. The complete package eliminates the need for additional pH ...
|
|
Rosemount/Rosemount Nuclear Transformer Connector 356
Introduction: Rosemount/Rosemount Nuclear Transformer Connectors 356 Rosemount 356 Nuclear Transformer Connectors are engineered to assemble the Rosemount 3152K Nuclear Transformer Pressure Transmitter to provide a reliable solution for harsh environments. This electrical conduit connector has a clamp-on disconnect design, which makes it easy to ...
|
|
Rosemount/Rosemount Ultrasonic Flow Meter USM341810
Introduction: Rosemount/Rosemount Ultrasonic Flow Meter USM341810, the new Rosemount 3418 Octal Ultrasonic Flow Meter is manufactured, developed, and engineered by Emerson to deliver high accuracy and best-in-class performance with the high functionality required by precision legal-for-trade users. 3418 Flow Meter ...
|
|
Rosemount/Rosemount vortex flowmeter 8600DF060 Caliber 25—200 mm
Introduction: The Rosemount/Rosemount Vortex Flow Meter 8600DF060 is optimized and cost-effective for general flow metering as well as clean fluid applications including steam, air, water, and nitrogen.
Features:
No moving parts, no repairs and no maintenance ...
|
|
Rosemount/Rosemount Level Switch 2110 Operating Pressure: -3.62—1450 psi
Introduction: Rosemount/Rosemount Level Switch 2110, The Rosemount 2110 Level Switch provides reliable level detection and reduces the need for maintenance for measurements in tight spaces and pipelines. Level applications and basic spill protection can be installed simply and quickly. Compliance with hygienic certifications, expanding the ...
|
|
Rosemount/Rosemount Hygienic Electromagnetic Flow Meter Sensor 8721010 1/2-4in tubing
Description: Rosemount/Rosemount Hygienic Electromagnetic Flowmeter Sensor 8721010 designed for food, beverage, and life science applications. All contact surfaces are manufactured using FDA-approved materials and are designed to meet 3A and EHEDG standards.
Features:
Light...
|
|
Rosemount/Rosemount Level Transmitter 326L with an accuracy of 7mm
Description: The Rosemount/Rosemount Level Transmitter 326L provides accurate and continuous level measurement for the food and beverage industry. The transmitter is hygienically certified (3-A, FDA, EC 1935, etc.), has a polished stainless steel housing, supports cleaning-in-place, reduces the risk of contamination and ensures ...
|
|
Rosemount/Rosemount Wireless Totalizer 705
Introduction: Rosemount/Rosemount Wireless Totalizer 705, make your turbine flow measurement more powerful with the Rosemount™ 705 Wireless Totalizer. The transmitter is equipped with wireless technology that continuously provides average flow rate and cumulative volume measurement, even in remote areas and in areas with ...
|
|
Rosemount/Rosemount Vibrating Tuning Fork Level Switch 2130 Operating temperature -70 to 260°
Description: The Rosemount/Rosemount Vibrating Tuning Fork Level Switch 2130 has been developed for challenging applications, harsh operating environments, and tight safety environments. The sturdy construction and built-in powerful diagnostics will keep you focused on your plant. Plug-and-play equipment, which means easy installation and ...
|
|
Rosemount/Rosemount Clamp-on Electromagnetic Flowmeter Sensor 8711010
Description: The Rosemount/Rosemount clip-on electromagnetic flowmeter sensor 8711010 and flangeless designs provide a compact, lightweight alternative to flanged magnetic flowmeters. Alignment gasket kit for easy installation.
Features:
Flange structure, dimensions and ...
|
|
Rosemount/Rosemount Non-Contact Level and Flow Transmitter 1208AG
Introduction: Rosemount/Rosemount Non-Contact Level and Flow Transmitter 1208AG, the Rosemount 1208 Series provides accurate and reliable level measurement and open channel flow calculations. The range includes two models designed to address water and wastewater applications, utilities, and simple level applications.
|
|