CHINT/CHINT DZ267LG-32 residual current operated circuit breaker

Create Date: 2024-8-30 12:03:23|Source: CHINT/CHINT

  • Brand:
    CHINT/CHINT
    Origin:
    chekiang
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    DZ267LG-32
    Product Introduction
    Protect the safety of people and electrical equipment, and have overload and short-circuit protection function,
Product Description
DZ267LG-32 residual current action circuit breaker (hereinafter referred to as residual current circuit breaker) is mainly suitable for AC 50Hz, rated voltage 230V, rated current to 32A circuit, when the person is electrocuted or the power grid leakage current or voltage exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply in a very short time, protect the safety of people and electrical equipment, and has an overload short circuit protection function, and can also turn on and off electrical devices and lighting circuits infrequently under normal circumstances, It is especially suitable for industrial and commercial lighting power distribution systems.
CHINT/CHINT DZ267LG-32 residual current operated circuit breaker

Comply with standards: GB/T 16917.1, IEC 61009-1

Main parameters and technical performance

Technical parameters itemParameter value
Rated voltage (Ue)230V AC
Rated current (In)6A、10A、16A、20A、25A、32A
Rated insulation voltage (Ui)500V
Rated impulse withstand voltage (Uimp)4kV
Rated residual operating current(△N)0.03A
Rated residual non-operating current (I△no)0.51An
Number of poles1P+ N
Instantaneous trip typeType C
Rated short-circuit breaking capacity (Icn)4500A
Overvoltage action value(280 ± 14) V
Rated residual on-off and breaking capacity (I△m)500A

This article introduces CHINT/CHINT DZ267LG-32 residual current action circuit breaker If you are interested, please also contact our customer service, we are looking forward to your call, and hope our technology and service can bring you a better experience.

The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
More on that
CHINT/CHINT HZ12 Series Combination Switch (Power Cut-off Switch) HZ12-40 CHINT/CHINT HZ12 Series Combination Switch (Power Cut-off Switch) HZ12-40

HZ12 series power cut-off switch is suitable for AC 50Hz or 60Hz, voltage to 550V circuit, as the power supply cut off and on. Comply with standards: GB/T 14048.3, IEC 60947-3. Ith A:40 Ui A:550 Ue V:380 Ie/A(AC-23A): 40 ...

CHINT/CHINT NBHLE-63 residual current action circuit breaker CHINT/CHINT NBHLE-63 residual current action circuit breaker

NBHLE-63 residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 63A line, play the role of overload, short circuit and leakage protection, can also be used as infrequent line on/off under normal circumstances. The product conforms to IEC61009-1, GB/T...

CHINT/CHINT HY23 Series Forward Switch HY23-132 CHINT/CHINT HY23 Series Forward Switch HY23-132

HY23 series instead of HZ3 series combination switch is suitable for AC 50Hz or 60Hz, voltage 380V circuit, as a power supply introduction switch, or as a three-phase squirrel cage induction motor with a control operation frequency of no more than 300 times per hour. Rated voltage: 380 Rated current: 30 Control Electricity ...

CHINT/CHINT CJ19 Series Switching Capacitor Contactor CJ19-63 CHINT/CHINT CJ19 Series Switching Capacitor Contactor CJ19-63

CJ19 series switching capacitor contactor (hereinafter referred to as contactor) is mainly used in power lines with AC 50Hz (or 60Hz) and rated working voltage to 690V, which is used for low-voltage reactive power compensation equipment to put in or remove low-voltage shunt capacitors. Contactors with inhibition ...

CHINT/CHINT Terminal Appliance OUVR-2 Self-resetting Over/Under Voltage Protector CHINT/CHINT Terminal Appliance OUVR-2 Self-resetting Over/Under Voltage Protector

OUVR-2 self-resettable over-under-voltage protector is a new type of intelligent protection electrical appliances, the product adopts modular standard design, when the power supply line appears over-voltage, under-voltage, the protector can quickly and safely cut off the circuit under the continuous high-voltage impact, to avoid abnormal voltage sent to the terminal electrical appliances to cause accidents.

CHINT/CHINT NPM8 series metal button CHINT/CHINT NPM8 series metal button

NPM8 series push buttons are suitable for industrial control, instrumentation, and household appliances with AC 50Hz (60Hz), rated working voltage AC220V and below, or DC working voltage DC110V and below. It is used for the control of electrical circuits of contactors, relays and other signals, with an indication ...

CHINT/CHINT CJ40 Series AC Contactor CJ40-1000 CHINT/CHINT CJ40 Series AC Contactor CJ40-1000

CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.

CHINT/CHINT LW6 series universal transfer switch CHINT/CHINT LW6 series universal transfer switch

LW6 series universal transfer switch is mainly suitable for control and conversion circuits in machine tool control circuits with AC 50Hz or 60Hz, voltage to 380V and DC voltage to 220V. It can also be used for the conversion of control circuits in other occasions, such as electromagnetic coils, electrical measuring instruments, etc. Standards: GB ...

CHINT/CHINT NB1L-40□ residual current action circuit breaker CHINT/CHINT NB1L-40□ residual current action circuit breaker

NB1L-40 □ residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 40A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be used in the pole ...

CHINT/CHINT NXB-63H miniature circuit breaker CHINT/CHINT NXB-63H miniature circuit breaker

Rated current (In): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A Rated working voltage (U): 230V-(1P, 1P+N), 400V-(2P-4P, 3P+N); Rated insulation voltage (Ui): 500V; Frequency: 50Hz Electromagnetic tripping ...

CHINT/CHINT CJ20 Series AC Contactor CJ20-25 CHINT/CHINT CJ20 Series AC Contactor CJ20-25

CJ20 series AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz (or 60Hz), rated working voltage to 660V, rated working current to 630A, for long-distance switching and breaking circuits, and can be combined with appropriate thermal overload relays.

CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-160 CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-160

CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...

CHINT/CHINT CJ20 Series AC Contactor CJ20-63 CHINT/CHINT CJ20 Series AC Contactor CJ20-63

CJ20 series AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz (or 60Hz), rated working voltage to 660V, rated working current to 630A, for long-distance switching and breaking circuits, and can be combined with appropriate thermal overload relays.

CHINT/CHINT NP6 series buttons CHINT/CHINT NP6 series buttons

The NP6 series push button is suitable for circuit control systems with AC 50Hz or 60Hz, voltage up to 220V, and DC working voltage up to 220V. It is also used in a wide range of fields, including numerical control equipment, instrumentation, and small control equipment, as a main order component or power switch. Indicator type button also ...

CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/40 CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/40

NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...

CHINT/CHINT NB1L-63 residual current action circuit breaker CHINT/CHINT NB1L-63 residual current action circuit breaker

NB1L-63 residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 63A in the line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be used in the pole ...

CHINT/CHINT Single Magnetic Circuit Breaker NB8-63M CHINT/CHINT Single Magnetic Circuit Breaker NB8-63M

Introduction: CHINT/CHINT Miniature Circuit Breaker NXB-40 is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection Product parameters Forehead...

CHINT/CHINT CJ20 series AC contactors CHINT/CHINT CJ20 series AC contactors

CJ20 series AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz (or 60Hz), rated working voltage to 660V, rated working current to 630A, for long-distance switching and breaking circuits, and can be combined with appropriate thermal overload relays.

CHINT/CHINT Miniature Circuit Breaker NXB-125G Quota voltage 230V CHINT/CHINT Miniature Circuit Breaker NXB-125G Quota voltage 230V

Introduction: CHINT/CHINT miniature circuit breaker NXB-125G is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection Product parameters ...

CHINT/CHINT NCH8G Home AC Contactor NCH8G-63/11 CHINT/CHINT NCH8G Home AC Contactor NCH8G-63/11

NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top