EATON UPS Power Supply Online 9E-20K Rated Capacity 20KVA

Create Date: 2024-8-30 12:03:23|Source: Eaton/Eaton

  • Brand:
    EATON/Eaton
    Origin:
    United States
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    9E-20K
    Product Introduction
    EATON/Eaton 9E-20K UPS Power Supply Online Output Voltage Range: AC 380V/220(±1%)V Output Frequency Range: 50/60HzHz Current Peak Ratio: 3:1 Output Power Factor: 0.9
Product Description
Product introduction of 9E-20K: Input voltage range -45-25%, 380V/220V input frequency range -45-65Hz Input harmonics <2% Input power 0.99 Output voltage range AC 380V/220(±1%)V Output frequency range 50/60HzHz.
Eaton UPS:
EATON UPS Power Supply Online 9E-20K Rated Capacity 20KVA
Basic parameters
UPS type
Online
Rated capacity
20KVA
Input and output parameters
Input voltage range
-45-25%,380V/220V
Enter the frequency range
-45-65Hz
Input harmonics
<2%
Enter the power factor
0.99
Output voltage range
AC 380V/220(±1%)V
Output frequency range
50/60HzHz
Current-to-peak ratio
3:1
Output power causes
0.9
Communications and Management
Interface port
RS-232, Mini-Slot communication slot
Battery and runtime
Backup time
Minutes depending on the capacity of the battery pack
Battery type
VRLA, AGM, gel batteries, or batteries specified by Eaton of any brand and model
Battery capacity
36×12VDC (adjustable)
Charging time
90% full capacity in 8 hours
environment
Working environment
Operating temperature: 0-40°C, Storage temperature: -25-55°C, Relative humidity: 5-95%
Noise level (dBA)
<55dB(A)
Other parameters
Exterior dimensions
636×420×955mm
Product weight
89kg
Other features
Static bypass: standard
Bypass Voltage: 380Vac (±5%)
Service Bypass: 20-80KVA (standard), 100-200KVA (option)


The above is the product introduction of EATON/Eaton UPS power supply online 9E-20K, this product introduction is: input voltage range -45-25%, 380V/220V input frequency range -45-65Hz input harmonics<2% Input Power Factor 0.99 Output Voltage Range AC 380V/220 (±1%)V Output Frequency Range 50/60HzHz. If you still have questions, you can communicate with customer service at any time, 76 Technology guarantees that all finished products are genuine and honest transactions. You choose 76 Technology, 76 Technology reports on the purchase experience with high quality, excellent service and strict control.
More on that
EATON UPS Power Supply Online 9E-40K Rated Capacity 40KVA EATON UPS Power Supply Online 9E-40K Rated Capacity 40KVA

Product introduction of 9E-40K: Output voltage range AC 380V/220(±1%)V Output frequency range 50/60HzHz Current to peak ratio 3:1 Output power 0.9 Working environment Operating temperature: 0-40°C, storage temperature: -25-55°C, relative humidity: 5-95%. Eaton UPS: ...

Eaton UPS Power Supply Inline, Tower EX 700VA Tower Eaton UPS Power Supply Inline, Tower EX 700VA Tower

EX 700VA Tower Product Introduction: Output Voltage Range (Adjustable to 200/208/220/240/250) 230V Output Frequency Range 50/60Hz Other Input Parameters Dual with 1 IEC C14 (10A) Socket Other Output Parameters Equipped with 6 IEC ...

Eaton UPS Power Supply 9PX Series 9104-12609-00P Eaton UPS Power Supply 9PX Series 9104-12609-00P

Product Brief of 9104-12609-00P: Power Class 5-11 kVA Rated Voltage 200/208/220/230/240V/250v Frequency 40-70 Hz Configuration Rack/Tower. Eaton UPS: The 9PX has distinctive features and stable ...

Eaton UPS Power Supply Inline, Tower Rack Dual-Purpose DX RT 6KVA Std Eaton UPS Power Supply Inline, Tower Rack Dual-Purpose DX RT 6KVA Std

DX RT 6KVA Std Product Introduction: Input Power Factor >0.99Output Voltage Norm 200/208/220/230/240VAC (Missing 220VAC) ±2%V Output Frequency Range (Battery Mode) 50±0.05Hz Output Power Factor 0.9 Other Output Parameters Voltage Distortion: 0.99 Output Voltage 200/20 ...

EATON UPS Power Supply Inline, Tower Rack Dual-purpose 9130 1500VA Tower EATON UPS Power Supply Inline, Tower Rack Dual-purpose 9130 1500VA Tower

9130 1500VA Tower Product Introduction: Input Voltage Range (Nominal 220-240) 160-276V Input Frequency Range 45-65Hz Output Frequency Range ±3%Hz Output Power 0.9 Other Input Parameters Nominal Current: 6.5A, 230V Rated Circuit Breaker: 10A. Eaton...

EATON UPS Power Supply In-line, Tower Rack Dual-purpose EX 2200 2U Rack/Tower EATON UPS Power Supply In-line, Tower Rack Dual-purpose EX 2200 2U Rack/Tower

EX 2200 2U Rack/Tower Product Introduction: Input Voltage Range: 100/120/160/184-284V Input Frequency Range: 40-70Hz Output Voltage Range (Adjustable to 200/208/220/240), 230V Output Frequency Range: 50/60Hz. Eaton UPS: The above is the EA...

EATON UPS Power Supply In-line, Tower Rackmount Dual-Purpose DX RT 6KVA Ext EATON UPS Power Supply In-line, Tower Rackmount Dual-Purpose DX RT 6KVA Ext

DX RT 6KVA Ext Product Introduction: Working Environment Operating Temperature: 0-40°C, Operating Humidity: 0-95% Storage Environment -20-55°C (without battery) Operating Altitude No derating for less than 1000m, 1% derating for every 100m increase above 1000m Noise level (dBA) ...

EATON/Eaton DX UPS 1–20 kVA DX UPS Telecommunications EATON/Eaton DX UPS 1–20 kVA DX UPS Telecommunications

1–20 kVA Product Introduction: Online double conversion topology, filter out all kinds of interference in the power grid, provide the purest power supply for critical loads The output power factor is 0.9, which provides 28% more effective power than other low power factor UPS input power factor >0.99, reducing the impact on the power grid.

EATON Eaton 9355 Marine UPS 9395-550-M EATON Eaton 9355 Marine UPS 9395-550-M

9395-550-M Product Introduction:This series of UPS is mainly used to protect the network equipment of emergency lighting systems, emergency public address systems, computer and communication systems, ship automation control systems and other applications of ships or offshore platforms. Eaton UPS: Core features ...

EATON UPS Power Supply In-line, Tower Rack Dual-purpose 9130 3000VA Tower EATON UPS Power Supply In-line, Tower Rack Dual-purpose 9130 3000VA Tower

9130 3000VA Tower Product Introduction: Input Voltage Range (Nominal 220-240) 180-276V Input Frequency Range 45-65Hz Output Power 0.9 Other Input Parameters Nominal Current 8.7A, 230V Rated Circuit Breaker: 10A. Eaton UPS: The above is EATON/...

EATON UPS Power Supplies Tower/Rack 9PX 11KVA Rated Capacity 11KVA EATON UPS Power Supplies Tower/Rack 9PX 11KVA Rated Capacity 11KVA

9PX 11KVA Product Introduction: Input Frequency Range 40-70Hz, 50/60Hz Input Harmonics Input Current Harmonics: THDI<5% Output Voltage Range 200/208/220/230/240V±1%V Other Input Parameters Frequency Range: Automatic Selection, Selectable Frequency Conversion Mode Other Output Parameters

EATON UPS Power Backup K500-Pro Voltage (162~268)VAC EATON UPS Power Backup K500-Pro Voltage (162~268)VAC

Product introduction of K500-Pro: The panel is simple and easy to operate. With DC power on function, anytime, anywhere, convenient for your use. High-quality batteries provide long-lasting, reliable power and plenty of backup time. Eaton UPS: Technical Parameters: Regulated output ...

EATON/Eaton 93 Series UPS 93PR-75-STD input capacity 25-75KVA EATON/Eaton 93 Series UPS 93PR-75-STD input capacity 25-75KVA

Product Brief for the 93PR-75-STD: This UPS meets the power assurance requirements of network equipment in wiring closets, small and medium-sized data centers, large data centers, automation or medical applications. Eaton UPS: Core features High scalability ...

EATON UPS Power Supply On-line, Tower EDX1000C Output frequency range 50/60Hz EATON UPS Power Supply On-line, Tower EDX1000C Output frequency range 50/60Hz

EDX1000C Product Introduction: Interface Port Standard RS232, SNMP Card (Option) Alarm Function Battery Mode Operation, Low Battery, General Fault, Overload, Bypass On/Off, Auto Start, Cold Start, Buzzer Off Protection Data Line: Included for Telephone/Modem ...

EATON UPS Power Supply Online 9E-160K Rated Capacity 160KVA EATON UPS Power Supply Online 9E-160K Rated Capacity 160KVA

Product Brief of 9E-160K: Input Voltage Range -45-25%, 380V/220V Input Frequency Range -45-65Hz Battery Type VRLA, AGM, Gel Battery, or Eaton's Designated Brand and Model Battery Capacity 36×12VDC (Adjustable) Charging Time ...

Eaton UPS EL650USBIEC Eaton UPS EL650USBIEC

Adapt to a variety of application scenarios Slim design It is easy to install and suitable for a variety of office environments A variety of mounting positions are supported Resettable circuit breaker is used The input short-circuit protection uses a resettable circuit breaker Save maintenance costs and time The output interface is sufficient Input short-circuit protection is ...

EATON UPS Power Backup K1000-Pro Voltage (162~268)VAC EATON UPS Power Backup K1000-Pro Voltage (162~268)VAC

K1000-Pro product introduction: The voltage input range of K500/1000-Pro UPS is 162VAC~268VAC, frequency range is 45Hz~55Hz, and provides reliable and stable power output. It can also be used with a generator. Eaton UPS: Technical Parameters: Regulated output K ...

EATON UPS Power Supply Online 9E-100K Input Voltage Range 45-25%, 380V/220V EATON UPS Power Supply Online 9E-100K Input Voltage Range 45-25%, 380V/220V

Product Brief for 9E-100K: Backup Time Minutes depending on battery pack capacity Battery Type VRLA AGM, gel batteries, or batteries specified by Eaton Battery capacity 36×12VDC (adjustable) Charging time 8 hours to reach 90% full capacity. Eaton UPS: ...

EATON UPS Power Supplies EDX6000H Wide input voltage range EATON UPS Power Supplies EDX6000H Wide input voltage range

EDX6000H Product Introduction: Eaton UPS power supplies EDX6000H wide input voltage range, suitable for the harshest power environments, double conversion topology to ensure maximum reliability, optional SNMP-based communication, provide remote monitoring of the network, fault tolerance automatic bypass, with built-in power ...

EATON UPS Power Supply Online Rack Type C2KR Voltage (110~300)VAC EATON UPS Power Supply Online Rack Type C2KR Voltage (110~300)VAC

C2KR Product Introduction: In order to prevent users from letting the UPS work in BYPASS MODE (bypass mode) without turning on the use, resulting in mains power interruption and abnormal shutdown of the UPS and equipment. Input normal mains, no bypass output by default. It must be turned on to have normal inverter output. But it can be done with Win...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top