C2KR Product Introduction: In order to prevent users from letting the UPS work in BYPASS MODE (bypass mode) without turning on the use, resulting in mains power interruption and abnormal shutdown of the UPS and equipment. Input normal mains, no bypass output by default. It must be turned on to have normal inverter output. However, the configuration can be changed to "Listed Electric Bypass Output" through WinPower2000 software.
Eaton UPS:
Technical parameters
Sine wave output
Whether in mains mode or battery mode, it can output a sine wave power supply with low distortion, providing the best power supply for the user's load equipment.
Zero changeover time
When the mains power is cut off or reinstated, there is no conversion time for the UPS to switch between the mains mode and the battery mode, which effectively ensures the reliability of the load operation.
Enter the zero-fire detection function
It has the function of reverse connection detection of zero live wire. to avoid the reverse connection of the zero live line of the UPS mains input.
User-friendly bypass output
In order to prevent users from making the UPS work in BYPASS MODE (bypass mode) without turning on the mains power, the UPS and the device will be shut down abnormally. Input normal mains, no bypass output by default. It must be turned on to have normal inverter output. However, the configuration can be changed to "Listed Electric Bypass Output" through WinPower2000 software.
TVSS function
That is, TRANSIENT VOLTAGE SURGE SUPPRESS. It is used on Rack UPS for conversion protection functions such as FAX, TELEPHONE, MODEM, and network.
Enter power corrections
Rack UPS has the input power factor correction function, which can reach more than 0.95 under full load, so that the user's power grid environment will not be polluted.
DC start
In the state of mains power failure, if you need to use UPS to start the computer or other load equipment, the UPS can directly use the battery for DC power on, making the use of UPS more convenient and reliable.
Bypass protection
The bypass power supply function greatly strengthens the emergency handling ability of UPS, and at the same time, when the user's load equipment has special requirements for the power supply, such as the voltage can not be too high, UPS provides bypass power supply voltage too high protection, so that the user's load equipment is free from high voltage danger.
Auto-start function
When the mains power is abnormal, enter the battery mode to power supply until the cut-off, the Rack UPS will shut down, and when the mains power returns to normal, the Rack UPS will automatically start to power on and restore normal power supply, without the need for users to turn on the power one by one.
Long-lasting power supply design
Rack UPS offers a comprehensive range of long-life machines for users to choose from. Equipped with a suitable battery pack, the discharge time can reach about 8 hours to meet the requirements of different power grid environments.
Powerful charging capacity of long-lasting machine
In addition to the extended discharge time, the Rack UPS long-lasting machine also has a strong battery recharge ability, which can provide an initial charging current of about 4-9A.
Self-check function
The Rack UPS can be used to simulate a power outage and enter battery mode to power the system, which can be performed at any time through the self-test button on the panel, or in conjunction with the monitoring software, on a regular or irregular basis.
Strong anti-interference
For electromagnetic interference and radio frequency interference, Rack UPS is designed in accordance with the international standard EN50091 - 2 and IEC61000-4 series standards, which effectively improves the safety and reliability of UPS.
Can be used with a generator
The wide input voltage and frequency range allows the Rack UPS to be used with major brands of generators for a longer period of time, while effectively removing the bad power generated by the generator, providing a pure, safe and stable power supply for the load.
Inductive loads can be connected
The Rack UPS can be connected to inductive loads (pf = 0.8).
Free download of WinPower2000 monitoring software from the website
In order to make the user's management of UPS more convenient and effective, WinPower2000 network version of monitoring software can be provided free of charge to achieve intelligent management.
Equipped with Intelligent Slot
The Rack UPS is equipped with an Intelligent Slot, which allows users to purchase an AS400 card (dry contact card) to provide IBM AS400 standard communication signals, and users can use the AS400 interface for remote display, including audible alarm and light display. Or purchase WebPower intelligent monitoring card for global management through the Internet, or through SNMP network management to achieve centralized monitoring and remote monitoring and other functions.
Equipped with a standard battery pack
The Rack UPS is configured with a standard battery pack of the same size as the host (for customers to choose). In addition to the C2KR, C3KR and C6KR standard machines are required to be equipped with one set of standard battery packs, the C1KRS and C6KRS long-lasting machines are also required to be equipped with more than 2 sets of standard battery packs, and the C2KRS and C3KRS long-acting machines are required to be equipped with more than 3 sets of standard battery packs. The batteries in the standard battery pack are made of high-quality batteries to ensure the safety and reliability of UPS with good battery quality.
Model | C1KR | C1KRS | C2KR | C2KRS | C3KR | C3KRS | C6KR | C6KRS | C10KR | C10KRS | Rated capacity | 1kVA | 2kVA | 3kVA | 6kVA | 10kVA | input | voltage | (110~300)VAC | (176~276)VAC | frequency | (40~70)Hz | (46~54/56~64)Hz | Causes | >0.99 | battery | External battery nominal voltage | — | 36VDC | 72VDC | 96VDC | 192VDC | Battery form | Maintenance-free lead-acid batteries | Number of batteries | 3PCS | — | output | voltage | 220(1±1%)VAC | frequency | Synchronization with input (mains mode) | 50 (1±0.2%)Hz (battery mode) | Overload capacity | 100%-110%: only warning tones;
110%-130%: automatically turn off after 1 minute, or switch to bypass mode when the input is normal;
>130%: Immediately turn off, or switch to bypass mode when input is normal. | 105%-125%,1min; 125%-135%,30S; 〉135%,0.5S | Output waveform | Pure sine wave | Output form | receptacle | Terminal blocks | Conversion time | Zero disruption | display screen | LCD display | LED/LCD display optional | Alarm sounds | The battery is discharged | When the input voltage is powered off, it is called every 4 seconds; When the battery is about to run out, it calls every second | The UPS is abnormal | Long beep | Auto-restart | After the battery is shut down, it can be automatically restarted when the mains power returns to normal | Communication interface | RS-232 | Intelligent monitoring functions such as abnormal mains power, power failure, battery capacity, UPS status indication, etc | Options | SNMP card, AS400 card, USB communication | Operating environment | temperature | 0℃~40℃ | humidity | 20%~90% | The overall dimensions of the host (W×D×H) mm | 482.6x450x88 | 482.6x600x130 | Exterior dimensions of the battery pack (W×D×H) mm | 482.6x450x88 | 482.6x600x130 | The weight of the main engine (net weight) kg | 16.3 | 9.1 | 10.3 | 11.5 | 11.2 | 12.3 | 18.3 | 18.5 | 19.2 | 19.5 |
The above is the EATON/Eaton UPS power supply online rack type C2KRThe product brief is:In order to prevent users from making the UPS work in BYPASS MODE (bypass mode) without turning on the mains power, the UPS and the device will be shut down abnormally. Input normal mains, no bypass output by default. It must be turned on to have normal inverter output. However, the configuration can be changed to "Listed Electric Bypass Output" through WinPower2000 software.
All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original genuine products, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, save money.
|
More on that
|
EATON UPS power supply online, tower EDX10000CXL rated capacity 10KVA
EDX10000CXL Product Introduction: Interface Port Standard RS232, SNMP Card (Option) Alarm Function Battery Mode Operation, Low Battery, General Fault, Overload, Bypass On/Off, Auto Start, Cold Start, Buzzer Off Protection Data Line: Included for Telephone/Modem ...
|
|
Eaton UPS Power Supply Tower 9SX1500I Power Class 700–3000 kVA
Product Brief for 9SX1500I: Power 700 VA - 3 kVA Voltage 200/208/220/230/240V Placement Tower Simplify on-site monitoring.
Eaton UPS:
Details: The Eaton 9SX UPS features a double-conversion topology with an internal static bypass ...
|
|
Eaton UPS Power Supply Tower 5P 1550i rated at 1100W
Product introduction of 5P 1550i: Input voltage range 160-294V, adjustable to 150-294V Input frequency range 50Hz system: 47-70Hz 60Hz system: 56.5-70Hz Low sensitivity mode 40Hz Output voltage range 230V (+6/-10%), adjustable to 200/208/220/230/ ...
|
|
EATON UPS Power Supply Online 9E-120K Input Frequency Range -45-65Hz
Product Brief for 9E-120K: Backup Time Minutes depending on battery pack capacity Battery Type VRLAAGM, gel batteries, or batteries specified by Eaton Battery capacity 36×12VDC (adjustable) Charging time 8 hours to reach 90% full capacity.
Eaton UPS:
...
|
|
Eaton UPS Power Supply Inline, Tower EX 700VA Tower
EX 700VA Tower Product Introduction: Output Voltage Range (Adjustable to 200/208/220/240/250) 230V Output Frequency Range 50/60Hz Other Input Parameters Dual with 1 IEC C14 (10A) Socket Other Output Parameters Equipped with 6 IEC ...
|
|
EATON/Eaton DX UPS 1–20 kVA DX UPS Telecommunications
1–20 kVA Product Introduction: Online double conversion topology, filter out all kinds of interference in the power grid, provide the purest power supply for critical loads The output power factor is 0.9, which provides 28% more effective power than other low power factor UPS input power factor >0.99, reducing the impact on the power grid.
|
|
Eaton UPS Power Supply Online DX 20K CNXL Rated Capacity 1-20KVA
DX 20K CNXL Product Introduction: Input Wiring Three-phase Linear + Ground Input Voltage Range 208-476V Input Frequency Range 45-70Hz Input Power Factor >0.99 Output Voltage Range 220/230/240V Output Frequency Range 50/60±0.05HZHz. Eaton UPS:
Above...
|
|
Eaton 9PX (5-11KVA) new
Product parameters
9PX8KiPM + 9PXEBM240
Eaton 9PX 8000i RT6U UPS
|
|
EATON UPS Power Supplies EDX6000H Wide input voltage range
EDX6000H Product Introduction: Eaton UPS power supplies EDX6000H wide input voltage range, suitable for the harshest power environments, double conversion topology to ensure maximum reliability, optional SNMP-based communication, provide remote monitoring of the network, fault tolerance automatic bypass, with built-in power ...
|
|
Eaton UPS EL650USBIEC
Adapt to a variety of application scenarios
Slim design
It is easy to install and suitable for a variety of office environments
A variety of mounting positions are supported
Resettable circuit breaker is used
The input short-circuit protection uses a resettable circuit breaker
Save maintenance costs and time
The output interface is sufficient
Input short-circuit protection is ...
|
|
EATON/Eaton 93 Series UPS 93PR-75-STD input capacity 25-75KVA
Product Brief for the 93PR-75-STD: This UPS meets the power assurance requirements of network equipment in wiring closets, small and medium-sized data centers, large data centers, automation or medical applications.
Eaton UPS:
Core features
High scalability
...
|
|
EATON UPS Power Supply Rack/Tower Interchange 9SX20KPMCH
Product Brief Introduction of 9SX20KPMCH: This product uses advanced technology to improve double conversion efficiency and reduce size, which helps users reduce electricity bills and save rack space costs. The UPS input and output can be compatible with both single-phase and three-phase power distribution, which improves the adaptability of different industry applications. Large size ...
|
|
Eaton UPS Power EX Series EX RT15002U Pulsar
EX RT15002U Product Description: Power class 700-3000 VA Rated voltage 220-240V frequency 50/60 Hz Configuration Rack/Tower product family Pulsar.
Eaton UPS:
The above is EATON/EA
|
|
Eaton UPS Power Supply DX-RT Series 9103-53492-00P
9103-53492-00P Product Introduction: With an output power factor of up to 0.9, the Eaton DX RT provides a more powerful load capacity, matching with modern computer equipment that has widely used input power factor correction circuits, and has small input harmonics and is environmentally friendly.
Eaton...
|
|
EATON UPS Power Supplies Tower/Rack 9PX 8KVA Rated Capacity 8KVA
Product Brief of 9PX 8KVA: Input Voltage Range 1:1,200/208/220/230/240/250V No Derating (Up to 100-276V When Derating)1:1,176-276V Input Frequency Range 40-70Hz,50/60Hz Input Harmonics Input Current Harmonics THDI<5% Output Voltage Range 200 ...
|
|
EATON UPS Power Supply RT2U Tower/Rack 5PX 3KVA 2U
Product Brief Introduction of 5PX 3KVA 2U: Rated Capacity 3KVA Rated Power 2700W Output Socket Input: (1) IEC C20 (16A) Socket Output: (8) IEC C13 (10A), (1) IEC C19 (16A) Socket Remote Control Socket: 2 sets of 2×IEC C13 (10A) Hot-swappable maintenance bypass ...
|
|
EATON UPS Power Supply On-line, Tower EDX10KCXL31 Output voltage range 380/220V
EDX10KCXL31 Product Introduction: Interface Port Standard RS232, SNMP Card (Option) Alarm Function Battery Mode Operation, Low Battery, General Fault, Overload, Bypass On/Off, Auto Start, Cold Start, Buzzer Off Protection Data Line: Included for Telephone/Modem ...
|
|
Eaton UPS Power Supply Inline, Tower Rackmount Dual-Purpose DX RT 2KVA Ext
DX RT 2KVA Ext Product Introduction:Input Power Factor ≥0.98Output Voltage Range 200/208/220/230/240 (Default 220V)±2%V Output Frequency Range (Battery Mode)50±0.05Hz Output Power 0.9 Other Output Parameters Voltage Distortion: ...
|
|
EATON UPS Power Supply Online 9E-80K Rated Capacity 80KVA
Product Brief of 9E-80K: Input Harmonics
|
|
EATON UPS Power Supply Online 9390-60-U Rated Power 60KVA
Product Brief for 9390-60-U: Output voltage range 380/400/415 +/-1%V Output frequency range 50± 1%Hz Battery type Fully sealed maintenance-free lead-acid battery Noise level (dBA) < 65.
Eaton UPS:
The above is EATON/EA
|
|