EATON/Eaton DX UPS 1–20 kVA DX UPS Telecommunications

Create Date: 2024-8-30 12:03:23|Source: Eaton/Eaton

  • Brand:
    EATON/Eaton
    Origin:
    United States
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    1–20 kVA
    Product Introduction
    EATON/Eaton 1–20 kVA DX UPS Home / Commercial Office Equipment Telecommunications, VoIP and other equipment Output power factor 0.9
Product Description
Product Brief for 1–20 kVA:The online double conversion topology filters out all kinds of interference in the power grid and provides the purest power supply for critical loads The output power factor is 0.9, which provides 28% more effective power than other low power factor UPSsThe input power factor >0.99 to reduce the interference to the power grid and peripheral equipment
EATON/Eaton DX UPS:
    EATON/Eaton DX UPS 1–20 kVA DX UPS Telecommunications

Eaton's UPS Power Supply DX Series UPS is a dual-conversion in-line UPS that effectively protects mission-critical from downtime, data loss and destruction. The UPS can accommodate input voltages from 110 V to 296 V, while its integrated rectifier and inverter completely isolate the output power from all abnormal inputs, making it suitable for harsh environments.

Apply:

• Residential/commercial office equipment

• Small and medium-sized data centers

• Telecommunications, VoIP and other equipment

• Banking & Security Systems • Medical Systems

• Manufacturing/control systems

• Laboratory equipment, precision instrumentation, etc

Performance

• On-line double conversion topology, filter out all kinds of interference in the power grid, and provide the purest power for critical loads

• Output power factor of 0.9, which provides 28% more effective power than other low power factor UPSs

• Input power factor >0.99 to reduce interference to the grid and peripheral equipment

High reliability

• Ultra-wide input range, compatible with generator input. Make the UPS use mains power supply under more conditions, and only use the battery when the mains power is seriously abnormal, so as to extend the discharge time of battery mode and the service life of the battery

• The high-power charger can quickly fill the battery and respond to the risk of sudden power failure in time. At the same time, it prevents damage to the battery caused by long-term undervoltage

• Redundant parallel function (6-20KVA), providing a higher level of power protection for critical systems, making the system reliability greater than 99.99%

• Built-in bypass switch automatically transfers the load to the mains power supply in the event of an overload or UPS failure. It ensures that the load is not powered on even in abnormal conditions

Easy to manage

• LED indicates UPS status, and LCD displays various UPS data information. Intimate knowledge of UPS and grid status

• Standard RS232 serial communication, smart card slot can be equipped with a variety of communication cards. Meet the different communication needs of customers

• Integrates seamlessly with Eaton's power management software for advanced virtualization environments and cloud-based management tools Easy to maintain • Tower-mounted design with small footprint for easy installation and maintenance • Compatible with maintenance bypass switch accessories to complete UPS maintenance and replacement without shutting down the load

The above is the product introduction of EATON/Eaton DX UPS 1–20 kVA, this introduction is: online double conversion topology, filter out all kinds of interference in the power grid, provide the purest power supply for critical loads The output power factor is 0.9, which provides 28% more effective power than other low power factor UPS input power factor >0.99, reducing the interference to the power grid and peripheral equipment.

All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original genuine products, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, save money.

More on that
EATON UPS Power Supply Online Interaction Form Factor Rack / Tower 9210-8366-00P EATON UPS Power Supply Online Interaction Form Factor Rack / Tower 9210-8366-00P

Product Brief for 9210-8366-00P[/backcolor]:[/backcolor]Power Class 1.5–3.0 kVA Rated voltage 200V / 208V / 220V / 230V / 240V Frequency 50 / 60 Hz +/- 0.1% Configure Tower / Rack. ...

EATON UPS Power Supply Online 9355-15-NC-0 Rated Power 15W EATON UPS Power Supply Online 9355-15-NC-0 Rated Power 15W

Product Brief for 9355-15-NC-0: Output Voltage Range 220/380, 230/400, 240/415 VAC/±20%V Output Frequency Range 50/60Hz Battery Type Maintenance-free VRLA battery. Eaton UPS: The above is ...

Eaton UPS Power Supply Inline, Tower EX 700VA Tower Eaton UPS Power Supply Inline, Tower EX 700VA Tower

EX 700VA Tower Product Introduction: Output Voltage Range (Adjustable to 200/208/220/240/250) 230V Output Frequency Range 50/60Hz Other Input Parameters Dual with 1 IEC C14 (10A) Socket Other Output Parameters Equipped with 6 IEC ...

EATON UPS Power Supply EDX15KHXL31 UPS Double Conversion Type EATON UPS Power Supply EDX15KHXL31 UPS Double Conversion Type

EDX15KHXL31 Product Introduction: The E-Series DX adapts to a wide input voltage range, avoiding the use of battery discharge during slight power fluctuations, and saving battery power for use when power is completely lost from the grid. Eaton UPS: Eaton UPS EDX15KHXL31 Technical Indicators ...

Eaton 9PX (5-11KVA) new Eaton 9PX (5-11KVA) new

Product parameters 9PX8KiPM + 9PXEBM240 Eaton 9PX 8000i RT6U UPS

EATON UPS Power Supply Online 9E-60K Input Frequency Range -45-65Hz EATON UPS Power Supply Online 9E-60K Input Frequency Range -45-65Hz

Product Brief Introduction of 9E-60K: Working Environment Operating Temperature: 0-40°C, Storage Temperature: -25-55°C, Relative Humidity: 5-95% Noise Level (dBA)

Eaton UPS Power Supply Inline, Tower Rack Dual-Purpose EX 3000 2U Rack/Tower Eaton UPS Power Supply Inline, Tower Rack Dual-Purpose EX 3000 2U Rack/Tower

EX 3000 2U Rack/Tower Product Introduction: Input Voltage Range 100/120/160/184-284V Input Frequency Range 40-70Hz Output Voltage Range (Adjustable to 200/208/220/240) 230V Output Frequency Range 50/60Hz Other Input Parameters Equipped with 1 IEC C20 ...

EATON UPS Power Supply Inline, Tower Rack Dual-purpose 9130 1500VA Tower EATON UPS Power Supply Inline, Tower Rack Dual-purpose 9130 1500VA Tower

9130 1500VA Tower Product Introduction: Input Voltage Range (Nominal 220-240) 160-276V Input Frequency Range 45-65Hz Output Frequency Range ±3%Hz Output Power 0.9 Other Input Parameters Nominal Current: 6.5A, 230V Rated Circuit Breaker: 10A. Eaton...

EATON UPS Power Backup K500-Pro Voltage (162~268)VAC EATON UPS Power Backup K500-Pro Voltage (162~268)VAC

Product introduction of K500-Pro: The panel is simple and easy to operate. With DC power on function, anytime, anywhere, convenient for your use. High-quality batteries provide long-lasting, reliable power and plenty of backup time. Eaton UPS: Technical Parameters: Regulated output ...

Eaton UPS Power Supply Tower 9SX1500I Power Class 700–3000 kVA Eaton UPS Power Supply Tower 9SX1500I Power Class 700–3000 kVA

Product Brief for 9SX1500I: Power 700 VA - 3 kVA Voltage 200/208/220/230/240V Placement Tower Simplify on-site monitoring. Eaton UPS: Details: The Eaton 9SX UPS features a double-conversion topology with an internal static bypass ...

Eaton UPS Power Supply Online Rack Type C1KRS Voltage (110~300)VAC Eaton UPS Power Supply Online Rack Type C1KRS Voltage (110~300)VAC

C1KRS product introduction: the bypass power supply function greatly strengthens the emergency handling ability of UPS, and at the same time, when the user's load equipment has special requirements for the power supply, such as the voltage can not be too high, UPS provides bypass power supply voltage too high protection, so that the user's load equipment is free from high voltage danger. He...

EATON UPS Power Supply Online Double Conversion Marine Type 9PHD-60-M EATON UPS Power Supply Online Double Conversion Marine Type 9PHD-60-M

Product introduction of 9PHD-60-M: This series of UPS is mainly used to protect the network equipment of emergency lighting systems, emergency public address systems, computer and communication systems, ship automation control systems and other applications of ships or offshore platforms. Eaton UPS: Eaton 935 ...

EATON UPS Power Supply Online 9E-100K Input Voltage Range 45-25%, 380V/220V EATON UPS Power Supply Online 9E-100K Input Voltage Range 45-25%, 380V/220V

Product Brief for 9E-100K: Backup Time Minutes depending on battery pack capacity Battery Type VRLA AGM, gel batteries, or batteries specified by Eaton Battery capacity 36×12VDC (adjustable) Charging time 8 hours to reach 90% full capacity. Eaton UPS: ...

EATON UPS Power Supply On-line, Tower EDX10KCXL31 Output voltage range 380/220V EATON UPS Power Supply On-line, Tower EDX10KCXL31 Output voltage range 380/220V

EDX10KCXL31 Product Introduction: Interface Port Standard RS232, SNMP Card (Option) Alarm Function Battery Mode Operation, Low Battery, General Fault, Overload, Bypass On/Off, Auto Start, Cold Start, Buzzer Off Protection Data Line: Included for Telephone/Modem ...

Eaton UPS Power Supply Inline, Tower Rackmount Dual-Purpose DX RT 3KVA Std Eaton UPS Power Supply Inline, Tower Rackmount Dual-Purpose DX RT 3KVA Std

DX RT 3KVA Std Product Introduction:Output Voltage Range 200/208/220/230/240 (Default 220V)±2%V Output Frequency Range (Battery Mode)50±0.05Hz Output Power 0.9 Other Output Parameters Voltage Distortion: ...

EATON/Eaton UPS in-line, tower rackmount dual-purpose DX RT 10KVA Std EATON/Eaton UPS in-line, tower rackmount dual-purpose DX RT 10KVA Std

DX RT 10KVA Std Product Introduction: Output Voltage Range 200/208/220/230/240VAC (220VAC Missing) ±2%V Output Frequency Range (Battery Mode) 50±0.05H Output Power 0.9Other Output Parameters Voltage Distortion: ...

Eaton UPS Power Supply 9155 Series 9155 (8-30KVA) Tower Unit Eaton UPS Power Supply 9155 Series 9155 (8-30KVA) Tower Unit

Product Brief for 9155 (8-30KVA): Power Class 8-30 KVA Voltage 220-230-240V Frequency 50/60 Hz Configure the Tower product family Powerware. Eaton UPS: Eaton UPS Power Supply 9155 - Technical Specifications   Give birth...

Eaton UPS Power Supply Tower 5P 850i Rated capacity 0.85KVA Eaton UPS Power Supply Tower 5P 850i Rated capacity 0.85KVA

The product introduction of 5P 850i is: Input Frequency Range 50Hz System: 47-70Hz 60Hz System: 56.5-70Hz Low Sensitivity Mode 40Hz Output Voltage Range 230V (+6/-10%), Adjustable to 200/208/220/230/240V Output Frequency Range 50/60H ...

Eaton UPS Power Supply 9PX Series 9104-12609-00P Eaton UPS Power Supply 9PX Series 9104-12609-00P

Product Brief of 9104-12609-00P: Power Class 5-11 kVA Rated Voltage 200/208/220/230/240V/250v Frequency 40-70 Hz Configuration Rack/Tower. Eaton UPS: The 9PX has distinctive features and stable ...

EATON UPS Power Supply Tower/Rack 9PX 2.2KVA Rated Capacity 2.2KVA EATON UPS Power Supply Tower/Rack 9PX 2.2KVA Rated Capacity 2.2KVA

Product Brief of 9PX 2.2KVA: Output Socket Input: (1)IEC C20 (16A), Output: (8)IEC C13 (10A)+(2)IEC C19 (16A) Maintenance Bypass Output via Hotswap: (6) IEC 10A Socket 2 Switch Socket Group Efficiency Mains Mode: Up to 93.5% (Maximum ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top