LC1E2510F5N Introduction: Schneider Electric Contactors, LC1E Series, 3 TeSys E
Schneider/Schneider _LC1E2510F5N
Model features introduced
Contactor LC1E series
LC1-E series AC contactors are mainly used in circuits with 50Hz (or 60Hz) AC current and 690V rated insulation voltage. These contactors can also be used in utilization category AC-3 circuits with a rated voltage of 380V and an operating current rating of up to 95A. These contactors provide long-distance connection and circuit break capabilities. These contactors can also be combined with suitable thermal overload relays to form electromagnetic starters to prevent possible overloads in the circuit. A contactor consists of three main systems: an electromagnetic system, a contact system, and an interjector system, among other components. (1) Electromagnetic system: The electromagnetic system includes a magnetic coil and an iron core, which is an important part of the contactor and is used to drive the closing and disconnection of the contact. (2) Contact system: The contact is the operating part of the contactor, mainly including the contact and the auxiliary contact. The basic function of the main contact is to connect and disconnect the main circuit and control high currents. Auxiliary contacts are part of the control loop and are used to meet the requirements of various control methods. (3) Interrupter system: The interrupter equipment is used to ensure that the arc generated when the contact is broken is extinguished, so as to reduce the damage caused by the arc to the contact. In order to quickly extinguish the arc caused by the open circuit, the contactor is usually fitted with a blocker device. Typically, semi-sealed clay stopper covers are used in conjunction with a magnetic blow-out circuit. (4) Other components: insulated shell and spring, short-circuit ring and transmission mechanism.
SchneiderElectricTeSysE series
Model parameters are introduced
attribute | numeric value | range | TeSysE | series | LC1E | Number of poles | 3 |
All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original genuine products, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, save money.
The above is the France brand Schneider / Schneider model for the LC1E2510F5N products, the introduction of this product is: Schneider Electric Schneider contactor, LC1E series, 3 TeSys E, the purpose of 76 technology is to survive by quality, develop by reputation, and eternal by service, give us a chance and give you a surprise.
|
More on that
|
Schneider _LC2DT20E7_ contactor 48 V AC coil
LC2DT20E7 Introduction: Schneider Electric contactors, LC2D series, 48 V AC coils, 4, minimum operating temperature -5°C Tesys D
Schneider/Schneider _LC2DT20E7
Model features introduced
Model parameters are introduced
76 Technology ...
|
|
Schneider LC1D18BDC 3-pole contactor
Description: Schneider Electric Contactors, LC1D Series, 24 V DC Coil, 18 A, 3 Locally Made TeSys D, 3 NO Contacts, Category AC3415V AC Switching Voltage3 Poles NO This series of contactors is certified for use in China.
...
|
|
Schneider _LRD05_ contactors and thermal overload relays with three poles
LRD05 Introduction: Schneider Electric Thermal Overload Relay LRD0 Series, 0.63 → 1 A, contact current rating 1 A
Schneider/Schneider_LRD05
Model features introduced
Three-pole thermal overload relay
Three-pole thermal overload relay design ...
|
|
Schneider _LC2D50A3V7_ contactors 300V DC, 690V AC
LC2D50A3V7 Introduction: Schneider Electric Contactors, LC2D Series, 400 V AC Coil, 3, Minimum Operating Temperature -5°C Tesys D
Schneider/Schneider_LC2D50A3V7
Model features introduced
Model parameters are introduced
Seventy-six ...
|
|
Schneider _LC1D25C7_ Contactor 3 NO contact 36 V
LC1D25C7 Introduction: Schneider Electric Contactors, LC1D Series, 36 V AC Coil, 25 A, 3 Tesys D, 3 NO Contacts
Schneider/Schneider_LC1D25C7
Model features introduced
3-pole contactor, AC controlled, rated power: 1 ...
|
|
Schneider _LC7K1210D7_ Contactor 3 NO contacts
LC7K1210D7 Introduction: Schneider Electric Contactors, LC7K Series, 42V AC Coil, 20 A, 3 TeSys K, 3 NO contacts
Schneider/Schneider _LC7K1210D7
Model features introduced
Model parameters are introduced
76 Technology ...
|
|
Schneider AC Contactor LC1-D09M7C AC220V
Introduction: LC1-D09M7C AC connector is mainly used for AC 50H or 60Hz, AC voltage to 660V (690V), when the working voltage is 220V under the AC-3 use category, the rated working current is 9A in the circuit, for keeping away from the connection and breaking circuits, and can be used with the corresponding specifications of ...
|
|
Schneider AC Contactor LC1-D12M7C AC220V
Introduction: D series AC contactors are rated for impulse withstand voltage of 6-8KV, and the protection level is IP 2X for preventing direct finger contact. It is suitable for controlling various types of motors, capacitors, lights, electric heating and other equipment.
Product parameters
Seven or six ...
|
|
Schneider_SR2A201BD_ Logic Modules Relay outputs are compact
SR2A201BD Introduction: Schneider Electric logic module, relay output, 12 x input, 8 x output, 24 V DC, 124.6 x 107.6 x 59.5 mm
Schneider/Schneider _SR2A201BD
Model features introduced
Zelio Logic Smart Relays - ...
|
|
Schneider Motor Starter TPRST025 25A 11 kW
Introduction: Schneider's TPRST025 direct starters are connected to the automatic controller via a bus coupler and are only operated when connected to a bus coupler, and are suitable for TPRBC bus couplers and TPRVM voltage interface modules.
...
|
|
Schneider _LP1K0910ND3_ contactors 60 V 20 A LP1K series
LP1K0910ND3 Introduction: Schneider Electric contactors, LP1K series, 60 V DC coil, 20 A, 3, min. -25°C TeSys K
Schneider/Schneider _LP1K0910ND3
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LAD8N20_ auxiliary contacts Screw clamp end 2 normally open
LAD8N20 Introduction: Schneider Electric contacts, LAD8 series, 2 contacts, screw clamp end side mounting, 2 normally open
Schneider/Schneider _LAD8N20
Model features introduced
Auxiliary contact block
Used with contactors or control relays rated ...
|
|
Schneider _LP1K09105ED_ contactor 48 V 20 A
LP1K09105ED Introduction: Schneider Electric contactors, LP1K series, 48 V DC coil, 20 A, 3, min. -25°C TeSys K
Schneider/Schneider _LP1K09105ED
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LC1D40008Z7_ Contactor 2 NO/2 NO
LC1D40008Z7 Introduction: Schneider Electric Contactors, LC1D Series, 4, min. -5°C Tesys D, 2 NO/2 NC contacts
Schneider/Schneider _LC1D40008Z7
Model features introduced
Model parameters are introduced
...
|
|
Schneider AC Contactor LC1-D12B7C 3P 50/60Hz
Introduction: LC1-D12B7C Schneider AC contactor is mainly used for AC 50Hz or 60Hz, AC voltage to 660V (690V), in the AC-3 use category when the working voltage is 220V, the rated working current is 9A in the circuit, for long-distance switching and breaking circuits, and can ...
|
|
Schneider _LC2K0910U7_ reversible contactor 230 V 9 A
LC2K0910U7 Introduction: Schneider Electric Reversible Contactor, LC2K Series, 230 V AC Coil, 9 A, 3, min. -25°C TeSys K
Schneider/Schneider _LC2K0910U7
Model features introduced
SchneiderElectr ...
|
|
Schneider _LC1D098UD_ Contactor LC1D Series 20 A
LC1D098UD Introduction: Schneider Electric contactors, LC1D series, 230 V DC coil, 20 A, 4, min. -5°C Tesys D
Schneider/Schneider _LC1D098UD
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LC2K0910N7_ reversible contactor screw clamp termination
LC2K0910N7 Introduction: Schneider Electric Reversible Contactor, LC2K Series, 400 V AC Coil, 9 A, 3 TeSys K, 3 NO contacts
Schneider/Schneider _LC2K0910N7
Model features introduced
3-pole reverse contactor with screw clamp
|
|
Schneider _LX1D8U5_ Contactor Accessories Line AC coils
LX1D8U5 Introduction: Schneider Electric contactor coils LX1D series for use in LC1 series
Schneider/Schneider _LX1D8U5
Model features introduced
D-Line AC coil
For LC1D115 and D150 contactors.
SchneiderElectric ...
|
|
Schneider_LC1D65AM7C_ Contactors Electrical 3 NO contacts
LC1D65AM7C Introduction: Schneider Electric contactors, LC1D series, 220 V AC coil, 65 A, 3 domestic TeSys D, 3 NO contacts
Schneider/Schneider _LC1D65AM7C
Model features introduced
3-pole AC and DC controlled contact ...
|
|