Schneider AC Contactor LC1-D12B7C 3P 50/60Hz

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

  • Brand:
    Schneider/Schneider
    Origin:
    France
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    LC1-D12B7C
    Product Introduction
    LC1-D12B7C AC contactor control coil 24VAC voltage, -5°C-+40°C, its average value within 24 hours does not exceed +35°C air temperature.
Product Description
Introduction: LC1-D12B7C Schneider AC contactor is mainly used for AC 50Hz or 60Hz, AC voltage to 660V (690V), when the working voltage is 220V under the AC-3 use category, the rated working current is 9A in the circuit, for long-distance switching and breaking circuits, and can be combined with the corresponding specifications of thermal relays to form a magnetic starter to protect the circuit that may be overloaded, the contactor is suitable for frequent starting and control of AC motors.

                            Schneider AC Contactor LC1-D12B7C 3P 50/60Hz

Product parameters

Control Coil Type: AC

Control coil voltage: 24VAC

Number of poles: 3P

Rated current: 12A

Main contact: 3NO

Coil frequency: 50/60Hz

Auxiliary contact: 1NO+1NC

The ambient air temperature is: -5 °C - +40 °C, and its average value does not exceed +35 °C within 24 hours;

Altitude: no more than 2000M;

Atmospheric conditions: at a temperature of +40 °C, the relative temperature of the air does not exceed 50 °C, and a higher relative temperature can be allowed at a lower temperature, such as 90% at 20 °C.

Pollution Grade: Level 3;

Installation Category: Three Categories;

The inclination between the mounting surface and the vertical surface is not more than ±5 degrees;

Shock and vibration: The product should be installed and used in a place where there is no significant shaking, shock and vibration.

The company respects the enterprise spirit of "practicality, hard work and responsibility", and creates a good corporate environment with integrity, win-win, and business philosophy, and takes a new management model, perfect technology, thoughtful service, and excellent quality as the foundation for survival. We always adhere to: customer first, serve customers attentively, and insist on impressing customers with their own services. Always adhering to the business philosophy of "integrity, win-win", relying on excellent prices, excellent quality, fast delivery and pre-sales consultation and after-sales service to win the trust of our customers.

This article introduces Schneider AC contactor LC1-D12B7C 3P 50/60Hz products, if you are interested in Schneider AC contactor, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.

More on that
Schneider _LC1D40AR7_ Contactor 3 NO contacts Schneider _LC1D40AR7_ Contactor 3 NO contacts

LC1D40AR7 Introduction: Schneider Electric Contactors, LC1D Series, 3, min. -5°C Tesys D, 3 NO contacts Schneider/Schneider _LC1D40AR7 Model features introduced Model parameters are introduced 76 Science and Technology Institute ...

Schneider _LC2D50A3V7_ contactors 300V DC, 690V AC Schneider _LC2D50A3V7_ contactors 300V DC, 690V AC

LC2D50A3V7 Introduction: Schneider Electric Contactors, LC2D Series, 400 V AC Coil, 3, Minimum Operating Temperature -5°C Tesys D Schneider/Schneider_LC2D50A3V7 Model features introduced Model parameters are introduced Seventy-six ...

Schneider _LC1D09G7_ contactor 110 V AC coil 3 NO Schneider _LC1D09G7_ contactor 110 V AC coil 3 NO

LC1D09G7 Introduction: Schneider Electric Contactors, LC1D Series, 110 V AC Coil, 9 A, 3 Tesys D, 3 NO contacts Schneider/Schneider _LC1D09G7 Model features introduced 3-pole DC controlled contactor Built-in coil suppression 3 ...

Schneider AC Contactor LC1-D12M7C AC220V Schneider AC Contactor LC1-D12M7C AC220V

Introduction: D series AC contactors are rated for impulse withstand voltage of 6-8KV, and the protection level is IP 2X for preventing direct finger contact. It is suitable for controlling various types of motors, capacitors, lights, electric heating and other equipment. Product parameters Seven or six ...

Schneider _LC1DT40MD_ Contactors 4-pole contactor, DC controlled Schneider _LC1DT40MD_ Contactors 4-pole contactor, DC controlled

LC1DT40MD Introduction: Schneider Electric contactors, LC1D series, 230 V DC coil, 40 A, 4 Tesys D, 4 NO contacts Schneider/Schneider_LC1DT40MD Model features introduced 4-pole contactor, DC controlled Use the category ...

Schneider _LC1D50ABBE_ contactor 3-pole DIN rail Schneider _LC1D50ABBE_ contactor 3-pole DIN rail

LC1D50ABBE Introduction: Schneider Electric contactors, LC1D series, 24 V DC coil, 50 A, 3, min. -25°C Tesys D Schneider/Schneider _LC1D50ABBE Model features introduced TeSysLC1D contactor Expert...

Schneider _LXD1U7_ Contactor Accessories Contactor coils Schneider _LXD1U7_ Contactor Accessories Contactor coils

LXD1U7 Introduction: Schneider Electric Contactor Coil LXD1 Series, used in LC1 series Schneider/Schneider _LXD1U7 Model features introduced Spare coils Model parameters are introduced All suppliers of 76 Technology have been strictly audited, ...

Schneider _LP2K09015BD_ contactor 24 V 20 A Schneider _LP2K09015BD_ contactor 24 V 20 A

LP2K09015BD Introduction: Schneider Electric contactors, LP2K series, 24 V DC coil, 20 A, 3, minimum operating temperature -25°C TeSys K Schneider/Schneider _LP2K09015BD Model features introduced Model parameters are introduced ...

Schneider _LC1D18BDC 3-pole AC and DC controlled contactors Schneider _LC1D18BDC 3-pole AC and DC controlled contactors

LC1D18BDC Introduction: Schneider Electric contactor, LC1D series, 24 V DC coil, 18 A, 3 domestic TeSys D, 3 NO contacts Schneider/Schneider _LC1D18BDC Model features introduced 3-pole AC and DC controlled contactors, ...

Schneider _LC1D128D7_ contactors 2 NO / 2 NC contacts Schneider _LC1D128D7_ contactors 2 NO / 2 NC contacts

LC1D128D7 Introduction: Schneider Electric Contactors, LC1D Series, 42V AC Coil, 25 A, 4 Tesys D, 2 NO/2 NC Contacts Schneider/Schneider _LC1D128D7 Model features introduced 4-pole contactor, DC controlled Envoy...

Schneider _LC1D40A6D7_ Contactor 3 NO contacts Schneider _LC1D40A6D7_ Contactor 3 NO contacts

LC1D40A6D7 Introduction: Schneider Electric Contactors, LC1D Series, 3, min. -5°C Tesys D, 3 NO contacts Schneider/Schneider_LC1D40A6D7 Model features introduced Model parameters are introduced 76 Technology ...

Schneider _LC1D50A6FC7_ contactor 3 NO contacts Schneider _LC1D50A6FC7_ contactor 3 NO contacts

LC1D50A6FC7 Introduction: Schneider Electric contactors, LC1D series, 3, min. -5°C Tesys D, 3 NO contacts Schneider/Schneider _LC1D50A6FC7 Model features introduced Model parameters are introduced Seven or six ...

Schneider _LAD8N20_ auxiliary contacts Screw clamp end 2 normally open Schneider _LAD8N20_ auxiliary contacts Screw clamp end 2 normally open

LAD8N20 Introduction: Schneider Electric contacts, LAD8 series, 2 contacts, screw clamp end side mounting, 2 normally open Schneider/Schneider _LAD8N20 Model features introduced Auxiliary contact block Used with contactors or control relays rated ...

Schneider _LP2K09103BD_ Contactor Electrical 20 A Schneider _LP2K09103BD_ Contactor Electrical 20 A

LP2K09103BD Introduction: Schneider Electric contactor, LP2K series, 24 V DC coil, 20 A, 3, min. -25°C TeSys K Schneider/Schneider _LP2K09103BD Model features introduced Model parameters are introduced ...

Schneider _LRD35_ contactors and thermal overload relays with a current of 38 A Schneider _LRD35_ contactors and thermal overload relays with a current of 38 A

LRD35 Introduction: Schneider Electric Thermal Relay LRD3 Series, 30 → 38 A, Contact Current Rating 38 A Schneider/Schneider_LRD35 Model features introduced Three-pole thermal overload relay The three-pole thermal overload relay is designed to protect against ...

Schneider _LP1K0910CD_ contactors LP1K series Schneider _LP1K0910CD_ contactors LP1K series

LP1K0910CD Introduction: Schneider Electric contactors, LP1K series, 36 V DC coil, 20 A, 3, minimum operating temperature -25°C TeSys K Schneider/Schneider_LP1K0910CD Model features introduced Model parameters are introduced ...

Schneider _LC1D40A3F7_ contactor 440 V AC coil 40 A Schneider _LC1D40A3F7_ contactor 440 V AC coil 40 A

LC1D40A3F7 Introduction: Schneider Electric Contactor, LC1D Series, 440 V AC Coil, 40 A, 3, min. -5°C Tesys D Schneider/Schneider _LC1D40A3F7 Model features introduced Model parameters are introduced ...

Schneider/Schneider _LC2D25BDV_ contactor 24 V DC coil 3 Schneider/Schneider _LC2D25BDV_ contactor 24 V DC coil 3

LC2D25BDV Introduction: Schneider Electric Contactors, LC2D Series, 24 V DC Coils, 3, Min. -5°C Operating Temperature Tesys D Schneider/Schneider _LC2D25BDV Model features introduced Model parameters are introduced 76 Technology ...

Schneider _LC1D65008FE7_ contactors 2 NO/2 NO Schneider _LC1D65008FE7_ contactors 2 NO/2 NO

LC1D65008FE7 Introduction: Schneider Electric Contactors, LC1D Series, 4, min. -5°C Tesys D, 2 NO/2 NC contacts Schneider/Schneider _LC1D65008FE7 Model features introduced Model parameters are introduced ...

Schneider/Schneider _LC1K12105V7_ contactor 400 V 20 A -25°C Schneider/Schneider _LC1K12105V7_ contactor 400 V 20 A -25°C

LC1K12105V7 Introduction: Schneider Electric contactors, LC1K series, 400 V AC coil, 20 A, 3, minimum operating temperature -25°C TeSys K Schneider/Schneider _LC1K12105V7 Model features introduced Model Parameters Introduction ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top