Product Introduction
Digital Display Controllers (Temperature Controllers)
RD Series (RD100 / RD400 / RD500 / RD700 / RD900)
Measurement accuracy: ±0.2% of displayed value
Sampling cycle: 0.25 seconds
11-segment LCD display
Dedicated Loader communication function
Plug-in construction
Main features Four types of settings can be registered
Four sets of setpoints (SV) can be logged in and switched via digital input (DI).
Rich outputs
*Analog transmission output may not be available depending on the type and type of control.
Rich output function combinations.
*The number of points for digital output is limited depending on the model and specifications.
*Analog transmission output may not be available depending on the type and type of control.
*In the case of RD100, you can choose between communication and digital inputs.
Adjustable Control Responsiveness (POST Fine-Tuning Function)
The responsiveness of the PID control characteristics calculated by the automatic calculation (AT) can be easily adjusted through the POST fine-tuning function. And choose from 6 levels of POST fine-tuning to the responsiveness you need.
Dedicated LOADER communication function
All models are equipped with a dedicated Loader communication function as standard.
It is easy to connect with a computer and set up with PROTEM 2 software
Main specifications:
Number of input points: 1 point
Input Type *Please refer to the input value range code table
1) **Class: Thermocouples K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII
2) The second category: temperature measuring resistor Pt100, JPt100
Sampling cycle: 0.25 seconds
Measurement accuracy: ± (0.2% of displayed value + 1 digit) *Varies depending on the input range
OUT1
1) Relay contact output: 1A contact
2) SSR voltage pulse output: DC 0/12V
3) Current output: DC 0-20mA, DC 4-20mA
4) Electric pressure output: DC0-5V, DC1-5V, DC0-10V
5) Open collector output: conversion mode
6) SSR (three-terminal bidirectional thyristor) output: rated 0.5A
< Optional Specifications >
OUT23 (OUT23) *You can select from different functions such as temperature control, alarm, heater disconnection alarm, loop disconnection alarm, and FAIL
1) Relay contact output: 1A contact
2) SSR voltage pulse output: DC 0/12V
3) Current output: DC 0-20mA, DC 4-20mA
4) Electric pressure output: DC0-5V, DC1-5V, DC0-10V
5) Open collector output: conversion mode
6) SSR (three-terminal bidirectional thyristor) output: rated 0.5A
Alarm/event output function (* 4 points more): temperature alarm, heater disconnection alarm, disconnection alarm, FAIL, etc
CT input for heater disconnection alarm (*2 points more)
Analog Transmission Output: The output method is the same as that of Output 1 (OUT 1) *Output from the Output 2 (OUT 2) position
Digital/Event/External Contact Input Function: * 2 points more
Communication function: RS-485 communication mode
< general specifications >
Power supply voltage (rated): AC100 - 240V / AC24V / DC24V
Ambient temperature: 0-50°C
Mass: RD100 about 120g
RD400 is about 185g
RD500 is about 190g
RD700 is about 200g
RD900 is about 250g
Safety Specification: UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE: Low Voltage Directive (LVD) EN61010-1
EMC Directive EN61326-1
|
More on that
|
RKC thermostat SA100FK06-MM-3*GN-NN/Y 250Ω external resistor
Main features
FM compliant temperature high/low limit controller
Limit the controller's actions
When the temperature controller detects an abnormal increase in temperature, such as a malfunction of the temperature control device, the limiting controller outputs a signal (relay contact output). Should...
|
|
Japan RKC physical and chemical REX-C100 FK02-V*AN temperature controller weighs 0.1Kg
Details of the product.
Brand: RKC.
Model: REX-C100FK02-V*AN.
Operating Voltage: 220(V)
Output Signal: 3 (mA)
Panel size: 48×48 mm.
Cut-out size: 45×45 mm.
Work...
|
|
Japan RIKA RKC PG500 resin pressure sensor Abundant input and output
Main features
Equipped with a large LED display
A large, high-brightness LED display is used to achieve visibility even from a distance
Abundant inputs and outputs
Equipped with digital input, analog output, alarm output, communication function, etc.
Product Introduction
...
|
|
RKC Portable Radiation Thermometer LTM-100 Degree of protection: IP67
Main features
Can be washed
It is waterproof and dustproof (IP67) and can be washed
The body uses antimicrobial resin and can be used hygienically
High-speed response
Press the measure button for 1 second to measure the temperature
When you press and hold the measurement key, you can ...
|
|
Japan RIKA RKC CH102 thermostat size 48*48mm
Product Introduction:
Japan RIKA RKC model CH102 CH series thermostat, this series of thermostats use large LEDs with good vision, can also be installed horizontally close, but also equipped with discriminant control status type self-correction function, is a cost-effective temperature control ...
|
|
Japan RKC physical and chemical COM-JE PLC communication converter
Main features
COM-JE
PLC communication converter
The controller and PLC can be connected without a program.
The COM-JE acts as the host computer and stores the controller's data in the PLC's registers.
It is only necessary to operate the PLC register commands, and the number of controllers can be easily handled.
|
|
Japan RIKA RKC RD100-MN-4*2N-NN digital display thermostat 1a contact
Product Introduction
Number of input points: 1 point
Input Type *Please refer to the input value range code table
1) **Class: Thermocouples K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII
2) The second category: temperature measuring resistor Pt100, JPt100
...
|
|
RKC thermostat RH100AD06-M*NN/Pt100, JPt100/rated 0.5A
Main features
Adjustable Control Responsiveness (POST Fine-Tuning Function)
The responsiveness of the PID control characteristics calculated by the automatic calculation (AT) can be easily adjusted through the POST fine-tuning function. And you can choose from 6 levels of POST fine-tuning function to choose the sound you need.
|
|
Japan Rika RKC MA901 Digital Display Multipoint Controller (Temperature Controller)
Product Introduction:
Japan Rika RKC MA901 digital display multipoint controller (temperature controller), plug-in structure, with 1 96mm square can achieve maximum 8CH temperature control, provide 2 types of 8CH and 4CH control specifications, to save control panel space; Loading...
|
|
Japan Rikaku RKC SRX modular thermostat Sampling cycle 0.025 seconds
Product Introduction:
Japan Rika RKC SRX modular thermostat, the series is divided into three modules: temperature control (TIO) module; Digital Input (DI) Module; Digital Output (DO) module. Measurement accuracy: ±0.1% of the displayed value; Sampling period: 0.02 ...
|
|
Japan RIKA RKC temperature controller MA900 / MA901 mass: about 560g
Introduction: Japan physical and chemical RKC temperature controller MA900 / MA901 mass: about 560g, current output: DC 0-20mA, DC 4-20mA, provide multi-storage area, contact input and output, communication and other rich functions.
peculiarity
With 1 96mm square can achieve a maximum of 8CH...
|
|
Japan Rikaku RKC AG500 digital display The sampling period is 0.1 seconds
Product Introduction:
The Japan RIKA RKC digital display, model AG500, is a replacement for the discontinued REX-AF4, which features a large, bright 5-digit LED display that can be read clearly from a distance. In the event of an abnormality such as an alarm, the measured value and the alarm character ...
|
|
RKC Thermostat Z-TIO-AT-DDDD/A2-F801 JPt100 (3-wire)
Main features
1 small module condensed with 4 temperature controllers
Four CHs can be controlled using one compact module. (Heating and cooling control type is 2 CH)
Temperature control module (Z-TIO) can be connected to up to 16 units (up to 64CH)
A variety of specializations are available.
|
|
Japan RIKA RKC CB500 thermostat thermostat CB100 400 700 900
Product Introduction
Weight: 0.5Kg
Mounting Type: Panel Mounting
Control Type: Thermostat
Output signal: 12mA
Temperature Range: 400 (°C)
Opening size: 45*45(mm)
Dimensions: 48*48(mm)
Job...
|
|
Japan physical and chemical RKC digital display thermostat RD500FK06-V*AN 11-segment LCD display
Product Introduction
Digital Display Controllers (Temperature Controllers)
RD Series (RD100 / RD400 / RD500 / RD700 / RD900)
Measurement accuracy: ±0.2% of displayed value
Sampling cycle: 0.25 seconds
11-segment LCD display
Dedicated Loader...
|
|
Japan Rika RKC ST-50 Temperature Sensor (Thermocouple)
Product Introduction:
Japan RIKA RKC ST-50 temperature sensor (thermocouple).
Brand: RKC
Origin: Japan
Model: ST-50
Product Type: Temperature Sensors (Thermocouples)
Wire diameter: 50μm
...
|
|
RKC thermostat CD701WR04-MM-AN-NN with RS-485 communication
Main features
Equipped with a self-tuning function of the judgment control state type
When the control state is judged to be disordered, the PID parameters are automatically adjusted
Loaded with auto-tuning function
Can be installed in close proximity
It can be installed in close contact, using the control panel or operating ...
|
|
RKC Digital Display AG500 Temperature Measuring Resistor: Pt100, JPt100
Main features
Large, bright display
It is equipped with a large, bright 5-digit LED display that can be read clearly from a distance.
In the event of an abnormality, such as an alarm, the measured value and the alarm character are displayed with each other
Abundant I/O functions (optional)
Available with ...
|
|
RKC Japan physical and chemical temperature control meter CD901F801-8*NN, weight 0.3Kg
Details of the product
Origin: Japan.
Brand: RKC/Physicochemical.
Model: CD901F-801-8*AN.
Control Type: Temperature.
Control Mode: Intelligent Temperature Control Regulator.
Measurement object: temperature.
Temperature range ...
|
|
Japan RKC physical and chemical heater disconnection alarm HBA-21 working voltage 220V
Product features
HBA-21 (for single phase contact control system)
Input Type: Current Detector (CV-1-□)
Detectable load current, depending on AC5A, AC30A, AC100A (CV-1 rating
Programmable range: CV-1 rating ...
|
|