Type Ethernet unit
PC Applications Number of sockets: TCP 8/UDP 0, Port number: 8,500 (can be set from 1 to 65,535)*1
Upper-bit link communication Number of sockets: TCP total 15/UDP 1, port number: 8,501 (can be set from 1 to 65,535)*2*3
MC protocol communication Number of sockets: TCP total 15/UDP 1, Port number: 5,000 (can be set from 1 to 65,536) *2*3*4
Connect VT3 Socket count: TCP 0/UDP 1, Port number: 8,502 (configurable from 1 to 65,535)
KV socket communication Number of sockets: Total TCP/UDP 8, Port number: Any (can be set from 1 to 65,535)*5
FTP Server Socket Count: TCP 4, Port Number: 20, 21
Automatic adjustment of clock data Socket word count: UDP 1, port number: 123
Mail Sending and Receiving (SMTP, POP3) Socket count: TCP 2, port number: 25, 110
Number of DNS sockets: UDP 1, port number: 53
FTP client socket count: TCP 2, port number: 20, 21 (configurable from 1 to 65,535)
Simple PLC Links Socket Count: UDP 1, Port Number: 5,001 (configurable from 1 to 65,535)
The internal current consumption is 80 mA or less
Weight approx. 120 g
This article introduces KEYENCE/KEYENCE Programmable Controller Ethernet Unit KV-8000 Series KV-LE21V products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business
|
More on that
|
KEYENCE/KEYENCE Fiber Optic Unit Reflective FU-12
Fiber optic unit permeable FU-12
Optical axis diameter (standard object to be detected): 10 × 3 mm
Optical axis width: 10 mm
Fiber optic device length: 2m free cut
Diameter of the fiber optic unit: ø2.2
Minimum bending radius: R2 mm without bending
Environmental Resistance Ambient Temperature: ...
|
|
KEYENCE/KEYENCE Ultra-High Speed Profile Gauge Controller LJ-V7001
Number of sensors that can be connected: Up to 2
Rated supply voltage 24 VDC ±10 % including ripple (P-P)
Current consumption: 1.3 A or less with 1 sensor head, 1.9 A or less with 2 sensor heads
Ambient temperature 0 to +50 °C
*1 Non-voltage input ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-18
Optical axis diameter (standard object to be detected): ø2.5 mm
The direction in which the light is emitted: Sideways
Opening angle: about 2°
Fiber optic device length: 2m free cut
Diameter of fiber optic unit: ø1.0
Minimum bending radius: R10 mm
Minimum detection object: ø0.1 mm*2
Environmental Resistance ...
|
|
KEYENCE/KEYENCE Programmable Controller KV-B16RC
16 point Screw terminal block relay output KV-B16RC
Type Output unit
External connection method Load-and-untack terminal block
The number of output points is 16 points
Output type: Relay
Rated load 250 VAC/30 VDC 2 A (8 A/1 common point)
ON Resistance 50 ...
|
|
KEYENCE/KEYENCE Controller PNP type LJ-V7001P
Number of sensors that can be connected: Up to 2
Current consumption: 1.3 A or less with 1 sensor head, 1.9 A or less with 2 sensor heads
Environmental resistance
Ambient temperature 0 to +50 °C
Relative humidity 85%RH or less (non-condensing)
Weight approx. 1,500 g
Root...
|
|
KEYENCE/KEYENCE Extension Cable CB-B05LU
Extension Cable - L-Connector (0.5 m)
Cable length: 0.5m
Weight: 70g
This article introduces KEYENCE/KEYENCE extension cable CB-B05LU products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to your ...
|
|
KEYENCE/KEYENCE Safety Light Curtains GL-R Series Infrared LEDs
Introduction: KEYENCE/KEYENCE Safety Light Curtains GL-R series have a rugged metal housing and double shock absorber construction to achieve twist, impact and impact resistance. In addition, the high power (49'+ range) and enclosure protection (IP65/IP67) make the GL-R withstand a wide range of harsh operating environments. Inside...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Reflective FU-33
Fiber Optic Unit Reflective FU-33
The direction in which the light is emitted: Sideways
Fiber Optic Device Length: 1m Free Cut
Diameter of the fibre optic unit: ø2.2×2
Minimum bending radius: R25 mm
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Ambient temperature: -40 ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Limited Reflective Type FU-38LK
Fiber optic unit limited reflective type FU-38LK
Heat-resistant temperature: 250°C*2
Fiber Optic Unit Length: Not 2m cut
Minimum bending radius: R25 mm
Environmental Resistance Ambient temperature: -40 to +250 °C
Weight: approx. 70 g
This article introduces KEYENCE/KEYENCE...
|
|
KEYENCE/KEYENCE EtherNet/IP™ Module CB-NEP20E
Power supply: Supplied by the controller
Environmental resistance
Ambient temperature: 0 to +45°C (DIN rail mounting), 0 to +40°C (bottom mounting)
Relative humidity: 35 to 85% RH (non-condensing)
Weight: approx. 500 g
This article introduces the KEYENCE/KEYENCE EtherNet/I...
|
|
KEYENCE/KEYENCE EtherCAT Unit CB-NEC20E
Communication speed: 100Mbps (100BASE-TX)
Communication cycle: 500 μs minimum
Connecting cables: STP cables from Category 5e onwards
Distance between nodes: 100 m
Communication port: RJ-45×2
Power supply: Supplied by the controller
Ambient temperature: 0 to +45°C
|
|
KEYENCE/KEYENCE Fiber Optic Unit Reflective FU-32
Optical axis diameter (standard object to be detected): ø0.6 mm
The direction in which the light is emitted: Sideways
Fiber Optic Device Length: 1m Free Cut
Diameter of the fibre optic unit: ø1.3
Minimum bending radius: R25 mm
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Environmental ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-13
Fiber Optic Unit Regressive Reflective FU-13
Fiber optic device length: 2m free cut
Diameter of the fibre optic unit: ø1.0×2
Minimum bending radius: R2 mm without bending
Environmental Resistance Ambient temperature: -40 to +50 °C
Weight: approx. 8 g
This article introduces the KEYENCE/KE...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Permeable FU-34
Optical axis diameter (standard object to be detected): ø1 mm
The direction in which the light is emitted: Sideways
Fiber optic device length: 2m free cut
Diameter of the fiber optic unit: ø2.2
Minimum bending radius: R25 mm
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Ambient Temperature ...
|
|
KEYENCE/KEYENCE sensor head LJ-X8400
Enclosure Rating: IP67(IEC60529)*10
Ambient light: Incandescent lamp: 10000 lux or less*11
Ambient temperature: 0 to +45°C*12
Relative humidity: 85%RH or less (no condensation)
Seismic resistance: 10 to 57 Hz Double amplitude 1.5 mm in each X, Y, Z direction
|
|
KEYENCE/KEYENCE Control Cable OP-87528
Type: Control cable NFPA79 compliant D-Sub9 pin included
Quantity: 1
Length: 5 m
This article introduces the KEYENCE/KEYENCE control cable OP-87528 product, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to hearing from you.
|
|
KEYENCE Keyence SR-2000 Series 2D Code Industrial Scanners
Wide-field, deep-field, ultra-high-speed barcode readers reach new levels of performance
Sensor: CMOS
Pixels: 2048
Indicator: LED
Resolution: 0.040 mm
Reading distance: 2000 mm
Range: 707
This article introduces KEYENCE/KEYENCE Keyence SR ...
|
|
KEYENCE/KEYENCE Amplifier Cable Main Unit NPN LV-N11N
KEYENCE/KEYENCE Amplifier Cable Main Unit NPN LV-N11N Type: 2 outputs
Output: NPN
Supply voltage: 24 VDC (operating voltage 10-30 VDC (including ripple)), ripple (P-P) 10 % or less, Class 2 or LPS*4*5
Power ...
|
|
KEYENCE/KEYENCE Extension Cable CB-B05LR
Extension Cable - L-Connector (0.5 m) CB-B05LR
Cable length: 0.5m
Weight: 70g
This article introduces the KEYENCE/KEYENCE extension cable CB-B05LR products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Reflective FU-35TG
Size: M6
Detection configuration: Coaxial
Length of fiber optic installation: 1m cannot be cut
Shape: Threaded
Minimum bending radius: R10 mm stainless steel
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Ambient temperature: -40 to +50 °C
Weight: approx. ...
|
|