Ergonomic, 3-position action of OFF ⇒ ON ⇒ OFF for danger avoidance.
Position 1 ⇒ 2, built-in snap-action switch with a light operating feel, making position 2 easy to identify. Position 2 ⇒ 3 requires force and a clear sense of operation.
The operating force of position 2 is reduced, and long-term operation is possible.
Even at the end of the operation button, a clear and stable sense of operation is achieved.
When you press OFF (position 3) ⇒ release OFF (position 1), the structure of the ON state is not formed. (IEC60204-1 ; 9.2.5.8, IEC60947-5-8; 7.1.9), 2-contact 3-position switch, which can be dualized for safety.
With rubber sleeve type, it can be used for waterproof structure (IP65).
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only by being professional and careful in every process, every action and every detail of the service can we meet or even exceed customer expectations and make customers satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.
This article introduces IDEC/Hequan HE3B enabling switch HE9Z-D3Y products, if you are interested in IDEC/Hequan, please also contact our staff, we are looking forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
IDEC/Izumi HE2B Enabling Switch HE2B-M211PN1
Ergonomic OFF ⇒ ON ⇒ OFF 3-position action for danger avoidance.
Position 2 ⇒ 3 requires force and a clear sense of operation.
Between pressing OFF (position 3) → releasing OFF (position 1), the structure of the ON state is not formed. IEC60204-1(2005) ...
|
|
IDEC/Izumi HS1L Type Solenoid Safety Switch HS1L-DQ44KMSRP-G
Low power consumption, built-in 6 contacts, and high level of 3000N locking strength.
The actuator is common to the HS1E type (3000N locking strength). 6. Built-in contact type, the same size as the original HS1E type.
The dimensions are 35mm× 104mm×129mm. It is possible to change the opening and closing state of the door and the lock separately.
|
|
IDEC/Izumi HE2B Enabling Switch HE2B-M222PN1
Ergonomic OFF ⇒ ON ⇒ OFF 3-position action for danger avoidance.
Position 2 ⇒ 3 requires force and a clear sense of operation.
Between pressing OFF (position 3) → releasing OFF (position 1), the structure of the ON state is not formed. IEC60204-1(2005) ...
|
|
IDEC/Izumi HE2B Enabling Switch HE2B-M211PB
Ergonomic OFF ⇒ ON ⇒ OFF 3-position action for danger avoidance.
Position 2 ⇒ 3 requires force and a clear sense of operation.
Between pressing OFF (position 3) → releasing OFF (position 1), the structure of the ON state is not formed. IEC60204-1(2005) ...
|
|
IDEC/Izumi HS1E-K Solenoid Safety Switch 3 Circuit Type HS1E-K844MSR-G-T001
All M3.5 wiring screws are used to improve the connection line.
The contact structure is 2 circuits with 1NC+1NC main circuit and 1NC auxiliary circuit, and it is possible to support dual main circuit + lock monitoring circuit.
There is also a key with a portable key as standard for hostage control ...
|
|
IDEC/Izumi HE1G Handheld Enabling Switch HE1G-20ME
3 position action of OFF ⇒ ON ⇒ OFF to avoid danger.
Pressing ON ⇒ OFF is a direct open-circuit action function.
By pressing OFF (position 3) ⇒ releasing OFF (position 1), there is no structure in the ON state.
(IEC60204-1; 9.2.5.8 ...
|
|
IDEC/Izumi HS1C-K Solenoid Safety Switch HS1C-K244R-G-T005
During mechanical operation, the guards/keys are securely locked.
Remove the key to unlock the safety gate, and keep the load circuit and auxiliary circuit open.
Ideal for applications where the key needs to be taken into a hazardous location to avoid accidental start-up of the device.
Key interlock type ...
|
|
IDEC/Izumi HE2B Enabling Switch HE2B-M211PY
Ergonomic OFF ⇒ ON ⇒ OFF 3-position action for danger avoidance.
Position 2 ⇒ 3 requires force and a clear sense of operation.
Between pressing OFF (position 3) → releasing OFF (position 1), the structure of the ON state is not formed. IEC60204-1(2005) ...
|
|
IDEC/Izumi HS5D Safety Switch HS5D-11RNP
It is equipped with a "operation head detachment detection function" that turns the main circuit (11-12) into the OFF state when the operating head falls off.
It is the same size as the HS5B type (external dimensions, mounting dimensions), and is available as a 3-contact model with dual contacts + auxiliary contacts. Small size allows installation in confined places ...
|
|
IDEC/Izumi HS1L Type Solenoid Safety Switch HS1L-DQ7Y4KMSRM-R
Low power consumption, built-in 6 contacts, and high level of 3000N locking strength.
The actuator is common to the HS1E type (3000N locking strength). 6. Built-in contact type, the same size as the original HS1E type.
The dimensions are 35mm× 104mm×129mm. It is possible to change the opening and closing state of the door and the lock separately.
|
|
IDEC/Izumi Safety Interlock HS5L-VB44M-G Interlock 4 CNT Spring Lock
4 Contacts, 1NC 1NO Gate, 2NC Lock Monitoring Circuit, Spring Lock
Compact body: 35x40x127mm
1400N locking strength
Gold-plated contacts for small loads
The head direction can be rotated
8 different actuator entries are allowed
Applicable standard: EN ISO14119
GS-ET ...
|
|
IDEC/Izumi HS7A-DMP non-contact safety switch HS7A-DMP5002
By connecting the signal of the auxiliary contact directly to the PLC, the operation of each HS7A-DMP non-contact safety switch can be monitored.
Ideal for installation on protective doors where positioning is difficult.
With the appropriate combination of dedicated safety relay modules, it is possible to correspond to safety category 4 and can be connected to up to 36 groups, protection, etc.
|
|
IDEC/Izumi HE1G-L Handheld Enabling Switch HE1G-L21SMC
3 position action of OFF ⇒ ON ⇒ OFF to avoid danger.
By pressing OFF (position 3) ⇒ releasing OFF (position 1), there is no structure in the ON state.
(IEC60204-1:2005, 10.9 terms, IEC60947-5-8:2007, 7.1.9 terms),
|
|
IDEC/Izumi HS5 Series Slip-in Door Handle Actuator HS9Z-EH5L
It has a metal frame with high impact resistance.
A 2-step operation to prevent malfunction.
The rear lever can be unlocked from the inside of the safety barrier, ensuring that in the event of a danger, the padlock is equipped with a lock to prevent unintentional start-up.
Sliding door double door, left door / right door ...
|
|
IDEC/Izumi HS1L Type Solenoid Safety Switch HS1L-R44KMSRP-R
Low power consumption, built-in 6 contacts, and high level of 3000N locking strength.
The actuator is common to the HS1E type (3000N locking strength). 6. Built-in contact type, the same size as the original HS1E type.
The dimensions are 35mm× 104mm×129mm. It is possible to change the opening and closing state of the door and the lock separately.
|
|
IDEC/Izumi HS1C-K Solenoid Safety Switch HS1C-K244R-G-T007
During mechanical operation, the guards/keys are securely locked.
Remove the key to unlock the safety gate, and keep the load circuit and auxiliary circuit open.
Ideal for applications where the key needs to be taken into a hazardous location to avoid accidental start-up of the device.
Key interlock type ...
|
|
IDEC/Izumi HS3A non-contact safety switch HS9Z-H3F805
The non-contact safety switch with RFID technology improves the safety performance.
Built-in safety features make the construction of a safety system independent of the combination with specific modules.
Thanks to the RFID method, there is no error even if the door closes slowly.
Even when installed on swing doors, sliding ...
|
|
IDEC/Izumi HW Series Rocker Switch HW1M-2222-22N9
It adopts a key selector switch with direct open-circuit action function and a high-security pin lock structure.
Key features:
The direct open-circuit action function does block the NC contacts. It is possible to easily build a system that ensures safety by switching modes, etc.
In combination with the HS5E-K key-locking safety switch, ...
|
|
IDEC/Izumi Safety Interlock HS5L Micro Lock HS5L-VA44LM-G
4 Contacts, 1NC 1NO Door 1NC 1NO Lock Supervisory Circuit, Spring Lock, Rear Unlock Button
Compact body: 35x40x127mm
1400N locking strength
Gold-plated contacts for small loads
The head direction can be rotated
8 different actuator entries are allowed
Applicable standard: EN ...
|
|
IDEC/Izumi HS1C-K Solenoid Safety Switch HS1C-K244R-G-T012
During mechanical operation, the guards/keys are securely locked.
Remove the key to unlock the safety gate, and keep the load circuit and auxiliary circuit open.
Ideal for applications where the key needs to be taken into a hazardous location to avoid accidental start-up of the device.