Pre-assembled relay modules with plug-in connections, including: relay base, relay holder, plug-in suppressor module and high-power contact relay with test button and integrated status LED. Contact type: 1 PDT. Input voltage: 120 V AC
The pluggable electromechanical and solid state relays as well as the base in the complete RIFLINE product range are certified and approved according to UL 508.
You can call up the relevant license certificate for each corresponding component that you want to view.
size
Width 16 mm
Height 96 mm
Depth 75 mm
Environmental conditions
Ambient temperature (operating) -40 °C ... 50 °C
Ambient temperature (storage / transport) -40 °C ... 85 °C
Degree of protection IP20 (relay base)
RT II (Relay)
Coil side
Rated input voltage UN 120 V AC
The input voltage range referenced to UN is shown in the graph
Trunk frequency 50/60 Hz
Typical input current at UN is 7 mA
Typical response time 4 ms ... 10 ms
Typical release time range 3 ms ... 20 ms
Coil voltage 120 V AC
Protection circuit varistor
The operating voltage is displayed with a yellow LED
Power consumption at rated conditions is 0.84 W
Contact side
Contact Type: 1 changeover contact
Switch contact type Single contact
Contact material AgNi
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 12 V at 10 mA
Minimum switching current 10 mA at 12 V
Maximum start-up current 32 A (20 ms, NO contact)
Limit continuous current to 8 A (see graph)
Maximum power rating (resistive load) 264 W (24 V DC)
62 W (for 48 V DC)
48 W (for 60 V DC)
52 W (for 110 V DC)
66 W (for 220 V DC)
2500 VA (can be used for 250VAC)
Minimum on-off capacity 120 mW
Switching capacity 2 A (at 24 V, 13 DCs)
3 A (at 240 V, AC15)
overview
Test voltage 4 kVrms (50 Hz, 1 minute, coil/contact)
Mode of operation 100% working factor
Flammability rating according to UL 94 V2 (enclosure)
Mechanical life: approx. 5 x 106 cycles
Installation Position Any
Assembly Instructions Arrangement without spacing
Connect your data
Connection Name Coil Side
Connection: Push-in connection
Stripping length 8 mm
Rigid conductor cross-section 0.14 mm² ... 1.5 mm²
Flexible conductor cross-section 0.14 mm² ... 1.5 mm²
0.14 mm² … 1.5 mm² (ferrule with plastic sleeve)
0.14 mm² … 1 mm² (sleeve with plastic insulating sleeve, two conductors on two-position terminals)
Attachable guide cross-section AWG 26 ... 16 (Rigid)
26 … 16 (Flexible)
Connect to data2
Connection Name Contact Side
Connection: Push-in connection
Stripping length 8 mm
Rigid conductor cross-section 0.14 mm² ... 1.5 mm²
Flexible conductor cross-section 0.14 mm² ... 1.5 mm²
0.14 mm² … 1.5 mm² (ferrule with plastic sleeve)
0.14 mm² … 1 mm² (sleeve with plastic insulating sleeve, two conductors on two-position terminals)
Attachable guide cross-section AWG 26 ... 16 (Rigid)
26 … 16 (Flexible)
Standards and Specifications
Standard/Procedure DIN EN 50178
Rated insulation voltage 250 V AC
Rated overvoltage 6 kV
Insulation: Safety isolation
Pollution class 2
Overvoltage category III
Conformance/Certification
Name Corrosive Gas Testing
Identifire: ISA-S71.04. G3 Harsh Group
EN 60068-2-60
All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original **, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, money.
The above is the Germany brand Phoenix/Phoenix relay module with manual operation locking function - RIF-1-RPT-LV-120AC/1X21MS - 2909776 products, the purpose of 76 technology is to survive by quality, develop by reputation, and eternal by service, give us a chance and give you a surprise.
|
More on that
|
Phoenix/Phoenix relay module PLC-RPT- 24UC/21-21AU/MS-2910526
PLC-INTERFACE, including relay base and pluggable multilayer gold contact relay with manual operation and integrated status LEDs, Push-in connection, 2 changeover contacts, bridge rectifier, input voltage: 24 V AC/DC
The maximum power consumption under the rated condition is 0.44 W
Test Electricity ...
|
|
Relay module with manually operated locking - PLC-RPT-120UC/21AU/MS - 2909674
PLC-INTERFACE, incl. PLC-BPT.../21 base terminal, plug-in connection, with manually operated plug-in miniature relay with multi-layer gold-plated contacts, 1 changeover contact, 120 V AC/110 V DC input voltage
size
Width 6.2 mm
Height 80 mm
...
|
|