KEYENCE/KEYENCE Fiber Optic Unit FU-22X
Fiber Optic Unit Reflective FU-22X
Fiber optic device length: 50cm cannot be cut
Minimum bending radius: R25 mm
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Ambient temperature: -40 to +70 °C
Weight: approx. 4 g
This article introduces KEYENCE/...
|
|
KEYENCE/KEYENCE Programmable Controller KV-B16RC
16 point Screw terminal block relay output KV-B16RC
Type Output unit
External connection method Load-and-untack terminal block
The number of output points is 16 points
Output type: Relay
Rated load 250 VAC/30 VDC 2 A (8 A/1 common point)
ON Resistance 50 ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Limited Reflective Type FU-38K
Fiber Optic Unit Limited Reflective Type FU-38K
Heat-resistant temperature: 250°C*2
Length of fiber optic installation: 1m cannot be cut
Minimum bending radius: R25 mm
Environmental Resistance Ambient temperature: -40 to +250 °C
Weight: approx. 45 g
This article introduces the KEYENCE/KEYENCE Light ...
|
|
KEYENCE/KEYENCE Subminiature Switching Power Supply CA-U4 (CA-U4#)
KEYENCE Subminiature Switching Power Supply CA-U4 (CA-U4#)
specification
This article introduces KEYENCE/KEYENCE subminiature switching power supply CA-U4 (CA-U4#) products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to your call, ...
|
|
KEYENCE 3D Development Edition Controller LJ-X8000ASO(55208)
Control Inputs: Start Batch Measurement (MEASURE_START), Stop Batch Measurement (MEASURE_STOP)
Control outputs: Trigger Ready (READY), System Error (ERROR), Solid State Relay*4:
Input/output synchronization: ...
|
|
KEYENCE/KEYENCE Programmable Controller KV-B8RC
KEYENCE/KEYENCE Programmable Controller KV-B8RC 8-Point Screw Terminal Block Relay Output (Stand-Alone General Purpose) Type: Output Unit
External connection: Load-and-remove terminal block
Number of output points: 8 points
Output Type: Relay
Rated load: 250 VAC/30 VDC ...
|
|
KEYENCE/KEYENCE Amplifier Neutral Expansion Unit LV-N10
Amplifier neutral expansion unit LV-N10
Control the output
NPN open collector 30 V, residual voltage 1 V or less (output current: 10 mA or less) / 2 V or less (output current: 10 to 100 mA)
(Independent) 1 maximum output: 100 mA or less ...
|
|
KEYENCE/KEYENCE Touch Panel Recorder TR-H Series has a capacity of 700MB
Introduction: KEYENCE/KEYENCE Touch Panel Recorder TR-H series has Hiragana/Kanji (Shift JIS) engraving, setting range dotting, additional dotting, and open panel detection functions; Pre-trigger dotting, ink ribbon allowance display, recording paper allowance display, recording paper shortage detection function ...
|
|
KEYENCE/KEYENCE Display Panel CA-MP81
Rated supply voltage: 24 VDC ±10 %
Rated current consumption: up to 1 A
Environmental resistance
Ambient temperature: 0 to +40 °C
Relative humidity: 35 to 85 % RH (non-condensing)
Weight: approx. 1,200 g
This article introduces the KEYENCE/KEYENCE display surface ...
|
|
KEYENCE/KEYENCE sensor head LJ-X8400
Enclosure Rating: IP67(IEC60529)*10
Ambient light: Incandescent lamp: 10000 lux or less*11
Ambient temperature: 0 to +45°C*12
Relative humidity: 85%RH or less (no condensation)
Seismic resistance: 10 to 57 Hz Double amplitude 1.5 mm in each X, Y, Z direction
|
|
KEYENCE/KEYENCE Ultra-High Speed Profile Gauge Controller LJ-V7001
Number of sensors that can be connected: Up to 2
Rated supply voltage 24 VDC ±10 % including ripple (P-P)
Current consumption: 1.3 A or less with 1 sensor head, 1.9 A or less with 2 sensor heads
Ambient temperature 0 to +50 °C
*1 Non-voltage input ...
|
|
KEYENCE/KEYENCE Programmable Controller KV Nano Series Rated load 30VDC
Introduction: KEYENCE/KEYENCE programmable controller KV Nano series has a built-in recording function. The dedicated wizard allows you to set the soft components you want to record and the timing of the trigger, and you can start recording by simply writing a ladder diagram of the start and stop of recording. It only takes 2 steps to set it up.
Product Features ...
|
|
KEYENCE/KEYENCE sensor head LJ-X8060
Sensor head LJ-X8060 reference distance: 64 mm
Enclosure Rating: IP67(IEC60529)*9
Ambient light: Incandescent lamp: 10000 lux or less*10
Ambient temperature: 0 to +45°C*11
Relative humidity: 85%RH or less (no condensation)
Seismic resistance: 10 to ...
|
|
KEYENCE/KEYENCE sensor head LJ-X8900
Sensor head LJ-X8900
Enclosure Rating: IP67(IEC60529)*9
Ambient light: Incandescent lamp: 10000 lux or less*10
Ambient temperature: 0 to +45°C*11
Relative humidity: 85%RH or less (no condensation)
Shock resistance: 10 to 57 Hz Double amplitude 1.5 mm ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-16
Fiber optic unit permeable FU-16
Optical axis diameter (standard object to be detected): ø2.5 mm
The direction in which the light is emitted: Sideways
Opening angle: Approximately 6°
Fiber optic device length: 2m free cut
Diameter of fiber optic unit: ø1.0
Minimum bending radius: R10 mm
Minimum Detection Matter ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-13
Fiber Optic Unit Regressive Reflective FU-13
Fiber optic device length: 2m free cut
Diameter of the fibre optic unit: ø1.0×2
Minimum bending radius: R2 mm without bending
Environmental Resistance Ambient temperature: -40 to +50 °C
Weight: approx. 8 g
This article introduces the KEYENCE/KE...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-16Z
Fiber Optic Unit Permeable FU-16Z
Optical axis diameter (standard object to be detected): ø2.5 mm
The direction in which the light is emitted: Sideways
Opening angle: Approximately 6°
Fiber optic device length: 2m free cut
Diameter of fiber optic unit: ø1.0
Minimum bending radius: R2 mm without bending
Least...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Limited Reflective Type FU-38
Fiber Optic Unit Limited Reflective Type FU-38
The direction in which the light is emitted: Bracket
Fiber optic device length: 2m free cut
Diameter of the fibre optic unit: ø1.0×2
Minimum bending radius: R10 mm
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Ambient Temperature: - ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Reflective FU-35TZ
Size: M3
Detection configuration: Coaxial
Fiber Optic Device Length: 1m Free Cut
Diameter of the fibre optic unit: ø1.3×2
Shape: Threaded
Minimum bending radius: R2 mm without bending
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Ambient Temperature: ...
|
|
KEYENCE Keyence SR-2000 Series 2D Code Industrial Scanners
Wide-field, deep-field, ultra-high-speed barcode readers reach new levels of performance
Sensor: CMOS
Pixels: 2048
Indicator: LED
Resolution: 0.040 mm
Reading distance: 2000 mm
Range: 707
This article introduces KEYENCE/KEYENCE Keyence SR ...
|