KEYENCE/KEYENCE Programmable Controller KV-5000/3000 Series
Introduction: KEYENCE/KEYENCE programmable controller KV-5000/3000 series enables seamless connection from FA equipment to PLC. Program-free PLC communication, excellent "responsiveness" expands new applications. KV-X MOTION strives to build a system that meets all needs.
Give birth...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-20
Fiber Optic Unit Reflective FU-20
Type: Small spot type
Distance to center: 5 mm
Fiber optic device length: 50cm cannot be cut
Minimum bending radius: R25 mm
Environmental Resistance Ambient temperature: -40 to +70 °C
Weight: approx. 2 g
This article introduces the KEYENCE/KE...
|
|
KEYENCE/KEYENCE Loose Wire -M12 Conversion Connector OP-88296
KEYENCE Loose Wire -M12 Conversion Connector OP-88296
specification
This article introduces the KEYENCE/KEYENCE Loose Wire -M12 Conversion Connector OP-88296 product, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to your ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-16
Fiber optic unit permeable FU-16
Optical axis diameter (standard object to be detected): ø2.5 mm
The direction in which the light is emitted: Sideways
Opening angle: Approximately 6°
Fiber optic device length: 2m free cut
Diameter of fiber optic unit: ø1.0
Minimum bending radius: R10 mm
Minimum Detection Matter ...
|
|
KEYENCE/KEYENCE Programmable Controller KV-B16TC
KEYENCE Programmable Controller KV-B16TC Type: Output unit
External connection: Load-and-remove terminal block
General method: 16 points/1 common point (2 terminals)*1
Operating time: OFF→ON: 10 μs or less, ON→OFF: 200 μs or less
Internal power consumption ...
|
|
KEYENCE/KEYENCE sensor head LJ-X8020
Sensor head LJ-X8020
Enclosure Rating: IP67(IEC60529)*9
Ambient light: Incandescent lamp: 10000 lux or less*10
Ambient temperature: 0 to +45°C*11
Relative humidity: 85%RH or less (no condensation)
Seismic resistance: 10 to 57 Hz Double amplitude 1.5 m ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Reflective FU-12
Fiber optic unit permeable FU-12
Optical axis diameter (standard object to be detected): 10 × 3 mm
Optical axis width: 10 mm
Fiber optic device length: 2m free cut
Diameter of the fiber optic unit: ø2.2
Minimum bending radius: R2 mm without bending
Environmental Resistance Ambient Temperature: ...
|
|
KEYENCE/KEYENCE Controller PNP type LJ-V7001P
Number of sensors that can be connected: Up to 2
Current consumption: 1.3 A or less with 1 sensor head, 1.9 A or less with 2 sensor heads
Environmental resistance
Ambient temperature 0 to +50 °C
Relative humidity 85%RH or less (non-condensing)
Weight approx. 1,500 g
Root...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Reflective FU-32
Optical axis diameter (standard object to be detected): ø0.6 mm
The direction in which the light is emitted: Sideways
Fiber Optic Device Length: 1m Free Cut
Diameter of the fibre optic unit: ø1.3
Minimum bending radius: R25 mm
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Environmental ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Permeable FU-35FA
Fiber Optic Unit Reflective FU-35FA
Size: M3
Detection configuration: Coaxial
Fiber Optic Device Length: 1m Free Cut
Diameter of the fibre optic unit: ø1.3×2
Shape: Straight
Minimum bending radius: R25 mm
Minimum detection object: ø0.005 mm gold wire*2
Ring...
|
|
KEYENCE/KEYENCE Programmable Controller KV-B16RC
16 point Screw terminal block relay output KV-B16RC
Type Output unit
External connection method Load-and-untack terminal block
The number of output points is 16 points
Output type: Relay
Rated load 250 VAC/30 VDC 2 A (8 A/1 common point)
ON Resistance 50 ...
|
|
KEYENCE/KEYENCE Display Panel CA-MP81
Rated supply voltage: 24 VDC ±10 %
Rated current consumption: up to 1 A
Environmental resistance
Ambient temperature: 0 to +40 °C
Relative humidity: 35 to 85 % RH (non-condensing)
Weight: approx. 1,200 g
This article introduces the KEYENCE/KEYENCE display surface ...
|
|
KEYENCE Keyence SR-2000 Series 2D Code Industrial Scanners
Wide-field, deep-field, ultra-high-speed barcode readers reach new levels of performance
Sensor: CMOS
Pixels: 2048
Indicator: LED
Resolution: 0.040 mm
Reading distance: 2000 mm
Range: 707
This article introduces KEYENCE/KEYENCE Keyence SR ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Limited Reflective Type FU-37
The direction in which the light is emitted: Sideways
Fiber optic device length: 2m free cut
Diameter of the fibre optic unit: ø1.0×2
Minimum bending radius: R10 mm
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Ambient temperature: -40 to +70 °C
Weight: approx. 6 g ...
|
|
KEYENCE/KEYENCE Hybrid Stepper Motor QS Series 2-phase bipolar
Introduction: KEYENCE/KEYENCE Hybrid Stepper Motor QS Series The motor is equipped with a large 3-color LED. In the event that an alarm occurs when there are multiple motors, it is possible to immediately find out which motor it is. In addition, the alarm content is displayed on the motor drive, so it is easier to grasp the content.
...
|
|
KEYENCE/KEYENCE add-on sensor module LK-HA100
KEYENCE add-on sensor module LK-HA100
specification
This article introduces the KEYENCE/KEYENCE add-on sensor module LK-HA100 product, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we look forward to your call, hope our technology ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Limited Reflective Type FU-38LK
Fiber optic unit limited reflective type FU-38LK
Heat-resistant temperature: 250°C*2
Fiber Optic Unit Length: Not 2m cut
Minimum bending radius: R25 mm
Environmental Resistance Ambient temperature: -40 to +250 °C
Weight: approx. 70 g
This article introduces KEYENCE/KEYENCE...
|
|
KEYENCE/KEYENCE Touch Panel VT3 Series Power Supply Voltage 24VDC ±10%
Introduction: KEYENCE/KEYENCE HMI VT3 series full-size TFT wonderful display; Picture directory, easy to call without drawing; Real parts, give you real experience; Humanized software, simple operation in one step; Data processing, powerful application functions; Vertical and horizontal, connecting ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Reflective FU-35FZ
KEYENCE Fiber Optic Unit Reflective FU-35FZ
Size M3
Detection configuration Coaxial
The length of the optical fiber device is 1m and can be cut freely
Fiber optic unit ø1.3×2 in diameter
Shape: Straight
The minimum bending radius R2 mm does not bend
Minimum detection object ø0.005 mm gold wire* ...
|
|
KEYENCE/KEYENCE Programmable Controller KV-B8RC
KEYENCE/KEYENCE Programmable Controller KV-B8RC 8-Point Screw Terminal Block Relay Output (Stand-Alone General Purpose) Type: Output Unit
External connection: Load-and-remove terminal block
Number of output points: 8 points
Output Type: Relay
Rated load: 250 VAC/30 VDC ...
|