Omron Multi-function Small Inverter MX2-ZV1 Series 3G3MX2-ZV1

Create Date: 2024-8-30 12:03:23|Source: Omron/Omron

  • Brand:
    Omron/Omron
    Origin:
    Japan
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    3G3MX2-ZV1
    Product Introduction
    Omron Multifunctional Small Inverter MX2-ZV1 Series 3G3MX2-ZV1 Coordinated motor and machine control Support for open networks
Product Description
Omron Multifunctional Small Inverter MX2-ZV1 Series 3G3MX2-ZV1 Coordinated motor and machine control Support for open networks

Easy position control with feedback

Position control can be achieved by receiving feedback pulses from the encoder.

In addition to the possibility of setting up to 8 positions in the inverter, the number of positioning sensors and limit switches can be reduced.

Network consolidation

Standard industrial networks such as EthereCAT, CompoNet or DeviceNet are optionally available.

With the Sysmac series, the high-speed EthereCAT is able to provide a complete solution for the entire system, from input to output.

Built-in RS-485 Modbus communication function.

Programming is flexible and convenient

The Drive programming tool allows customers to tailor the program to their machine (e.g. for square roll applications).

Allows up to 1000 lines of code and 5 tasks to run in parallel in 2 programming modes.

Motor control

Permanent magnet synchronous motor

Permanent magnet motors with high efficiency magnetism can be controlled.

Permanent magnet motors can further improve energy savings, resulting in more environmentally friendly machine control.

Torque sensors

Since the MX2 has a near-stationary (0.5Hz) starting torque of 200% and torque control operation in open-loop mode, it can also be used in applications where closed-loop vector control was previously used.

Built-in safety device

There is no need to use a contactor to stop the motor, and it can be fully combined with an Omron safety controller.

EN ISO13849-1:2008(Cat.3/PLd)

IEC60204-1 Stop Level 0
The name of the feature
specification
Protective structure *1
Open (IP20)
control
Control mode
Sine wave modulated PWM mode
Output frequency range*2
0.10~400Hz (HF mode: 580Hz is limited)
Frequency accuracy*3
Digital Commands: ±0.01% Max, Analog Commands: ±0.2% Max (25±10°C)
Frequency setting
resolution
Digital setting: 0.01Hz, analog setting: 1/1000 of the maximum frequency
Voltage/frequency characteristics
V/f characteristics (constant rotational pitch/reduced torque)
Sensorless vector control, V/f control with speed feedback
Overload current rating
Heavy Duty Rating (CT): 150%/60s
Light load rating (CT): 120%/60s
Instantaneous overcurrent quick break protection
200% of CT
Acceleration/deceleration time
0.01~3600s (line/curve selection), the second acceleration/deceleration setting is available
Carrier frequency adjustment range
2~15kHz (with derating)
Starting torque
200%/0.5Hz (Sensorless Vector Control)
External DC braking
When decelerating with the STOP command lowers the operating frequency or below the set value during operation,
Or when acting through external input. (The level and time can be set).
Protection features
Over-current protection, over-voltage protection, under-voltage protection, electric thermal protection, temperature anomaly protection,
- Ground fault overcurrent protection on power-up, inrush current protection circuit, overload limit, input overvoltage protection,
- External trips, memory errors, CPU errors, USP errors, communication errors,
Overvoltage suppression during deceleration, instantaneous power failure protection, emergency circuit breaking, etc.
Enter the signal
Frequency setting
Digital manipulator
External analog input signal: DC 0~10V/4~20mA, Modbus communication (Modbus-RTU)
Run/stop commands
Digital manipulator
External digital input signal (3-wire input supported), Modbus communication (Modbus-RTU)
Multi-function input
7 points (59 optional functions)
Analog inputs
2 points (voltage FV terminal: 10 bits/0~10V, current FI terminal: 10 bits/4~20mA)
Pulse input
1 point (RP terminal: max. 32kHz, DC 5~24V)
Output signal
Multi-function output
2 points (P1/EDM, P2; 43 optional functions)
Relay output
Point 1 (1c contact: MC, MA, MB; 43 optional functions)
Analog output
(Frequency Monitoring)
1 point (AM terminal: voltage 10 bits/0~10V) (frequency, current optional)
Pulse output
1 point (MP terminal: 32kHz max., 0~10V)
correspondence
RS-422
RJ45 connector (for digital manipulators)
RS-485
Control Circuit Terminal Block, Modbus Communication (Modbus-RTU)
USB
USB1.1, mini-B connector
Driver programming*4
Calculation, logic, control I/O, etc
Other features
AVR function, V/f feature switching, upper and lower limit limit, 16-band multi-speed range, start-up frequency adjustment,
Jog Operation, Carrier Frequency Adjustment, PID Control, Frequency Jump, Analog Gain/Deviation Adjustment,
S-shaped acceleration/deceleration, electrothermal protection features, level adjustment, restart function, torque compensation function,
Abnormal Monitoring, Software Lock Function, Frequency Conversion Display, USP Function, Motor 2 Control Function,
UP/DOWN and overcurrent control functions, etc
Operating environment
Operating ambient temperature
-10~50°C (derating is required if the specified value is exceeded)
Store at ambient temperature
-20℃~65℃
Humidity of the working environment
20%~90%RH (no condensation)
Vibration resistant
5.9m/s2(0.6G)、10~55Hz
Applicable environment
below 1000m above sea level; Indoor (no corrosive gases, dust)
Optional
EtherCAT communication unit
3G3AX-MX2-ECT
CompoNet communication unit
3G3AX-MX2-CRT-E
DeviceNet Communication Unit
3G3AX-MX2-DRT-E
Other options
DC reactors, AC reactors, radio noise filters, input-side noise filters,
Output-side noise filters, regenerative braking units, braking resistors, and EMC noise filters, etc
International standards
EC
directives
EMC Directive
EN61800-3: 2004
Low Voltage Directive
EN61800-5-1: 2007
Machinery Directive
IEC60204-1 Stop class 0, EN IEC61800-5-2 (STO), EN ISO13849-1: 2008 (PLd)
UL/cUL
UL508C

Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only when every process, every action and every detail of the service is professional and careful, can we meet or even exceed the expectations of customers, so that customers can be satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.

This article introduces the Omron multifunctional small inverter 3G3MX2-ZV1N products, if you are interested in Omron, please also contact our staff, we are looking forward to your call, hope our technology and service can bring you a better experience.
More on that
Omron 3G3RX2 high-performance general-purpose inverter IP20*5 Omron 3G3RX2 high-performance general-purpose inverter IP20*5

Introduction: Omron/Omron 3G3RX2 high-performance general-purpose inverter IP20*5, rated output voltage three-phase (3-wire) 200~240V (depending on the receiving voltage) is suitable for various applications. Contributes to energy savings and performance.   peculiarity Simple replacement Expansion of built-in regeneration ...

Omron/Omron 3G3RX Advanced General Purpose Inverter Heat dissipation mode: forced air cooling Omron/Omron 3G3RX Advanced General Purpose Inverter Heat dissipation mode: forced air cooling

Introduction: Omron/Omron 3G3RX Advanced General Inverter Heat dissipation mode: forced air cooling, control mode two-phase sinusoidal modulation PWM, output frequency range 0.1~400Hz.   peculiarity Pay attention to the environment Easy to operate Support more applications parameter    ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top