C1KR's Product Introduction:The wide input voltage and frequency range allows the Rack UPS to be used with major brands of generators for a longer period of time, while effectively removing the bad power generated by the generator, providing a pure, safe and stable power supply for the load.
Eaton UPS:
Technical parameters
Sine wave output
Whether in mains mode or battery mode, it can output a sine wave power supply with low distortion, providing the best power supply for the user's load equipment.
Zero changeover time
When the mains power is cut off or reinstated, there is no conversion time for the UPS to switch between the mains mode and the battery mode, which effectively ensures the reliability of the load operation.
Enter the zero-fire detection function
It has the function of reverse connection detection of zero live wire. to avoid the reverse connection of the zero live line of the UPS mains input.
User-friendly bypass output
In order to prevent users from making the UPS work in BYPASS MODE (bypass mode) without turning on the mains power, the UPS and the device will be shut down abnormally. Input normal mains, no bypass output by default. It must be turned on to have normal inverter output. However, the configuration can be changed to "Listed Electric Bypass Output" through WinPower2000 software.
TVSS function
That is, TRANSIENT VOLTAGE SURGE SUPPRESS. It is used on Rack UPS for conversion protection functions such as FAX, TELEPHONE, MODEM, and network.
Enter power corrections
Rack UPS has the input power factor correction function, which can reach more than 0.95 under full load, so that the user's power grid environment will not be polluted.
DC start
In the state of mains power failure, if you need to use UPS to start the computer or other load equipment, the UPS can directly use the battery for DC power on, making the use of UPS more convenient and reliable.
Bypass protection
The bypass power supply function greatly strengthens the emergency handling ability of UPS, and at the same time, when the user's load equipment has special requirements for the power supply, such as the voltage can not be too high, UPS provides bypass power supply voltage too high protection, so that the user's load equipment is free from high voltage danger.
Auto-start function
When the mains power is abnormal, enter the battery mode to power supply until the cut-off, the Rack UPS will shut down, and when the mains power returns to normal, the Rack UPS will automatically start to power on and restore normal power supply, without the need for users to turn on the power one by one.
Long-lasting power supply design
Rack UPS offers a comprehensive range of long-life machines for users to choose from. Equipped with a suitable battery pack, the discharge time can reach about 8 hours to meet the requirements of different power grid environments.
Powerful charging capacity of long-lasting machine
In addition to the extended discharge time, the Rack UPS long-lasting machine also has a strong battery recharge ability, which can provide an initial charging current of about 4-9A.
Self-check function
The Rack UPS can be used to simulate a power outage and enter battery mode to power the system, which can be performed at any time through the self-test button on the panel, or in conjunction with the monitoring software, on a regular or irregular basis.
Strong anti-interference
For electromagnetic interference and radio frequency interference, Rack UPS is designed in accordance with the international standard EN50091 - 2 and IEC61000-4 series standards, which effectively improves the safety and reliability of UPS.
Can be used with a generator
The wide input voltage and frequency range allows the Rack UPS to be used with major brands of generators for a longer period of time, while effectively removing the bad power generated by the generator, providing a pure, safe and stable power supply for the load.
Inductive loads can be connected
The Rack UPS can be connected to inductive loads (pf = 0.8).
Free download of WinPower2000 monitoring software from the website
In order to make the user's management of UPS more convenient and effective, WinPower2000 network version of monitoring software can be provided free of charge to achieve intelligent management.
Equipped with Intelligent Slot
The Rack UPS is equipped with an Intelligent Slot, which allows users to purchase an AS400 card (dry contact card) to provide IBM AS400 standard communication signals, and users can use the AS400 interface for remote display, including audible alarm and light display. Or purchase WebPower intelligent monitoring card for global management through the Internet, or through SNMP network management to achieve centralized monitoring and remote monitoring and other functions.
Equipped with a standard battery pack
The Rack UPS is configured with a standard battery pack of the same size as the host (for customers to choose). In addition to the C2KR, C3KR and C6KR standard machines are required to be equipped with one set of standard battery packs, the C1KRS and C6KRS long-lasting machines are also required to be equipped with more than 2 sets of standard battery packs, and the C2KRS and C3KRS long-acting machines are required to be equipped with more than 3 sets of standard battery packs. The batteries in the standard battery pack are made of high-quality batteries to ensure the safety and reliability of UPS with good battery quality.
Model | C1KR | C1KRS | C2KR | C2KRS | C3KR | C3KRS | C6KR | C6KRS | C10KR | C10KRS | Rated capacity | 1kVA | 2kVA | 3kVA | 6kVA | 10kVA | input | voltage | (110~300)VAC | (176~276)VAC | frequency | (40~70)Hz | (46~54/56~64)Hz | Causes | >0.99 | battery | External battery nominal voltage | — | 36VDC | 72VDC | 96VDC | 192VDC | Battery form | Maintenance-free lead-acid batteries | Number of batteries | 3PCS | — | output | voltage | 220(1±1%)VAC | frequency | Synchronization with input (mains mode) | 50 (1±0.2%)Hz (battery mode) | Overload capacity | 100%-110%: only warning tones;
110%-130%: automatically turn off after 1 minute, or switch to bypass mode when the input is normal;
>130%: Immediately turn off, or switch to bypass mode when input is normal. | 105%-125%,1min; 125%-135%,30S; 〉135%,0.5S | Output waveform | Pure sine wave | Output form | receptacle | Terminal blocks | Conversion time | Zero disruption | display screen | LCD display | LED/LCD display optional | Alarm sounds | The battery is discharged | When the input voltage is powered off, it is called every 4 seconds; When the battery is about to run out, it calls every second | The UPS is abnormal | Long beep | Auto-restart | After the battery is shut down, it can be automatically restarted when the mains power returns to normal | Communication interface | RS-232 | Intelligent monitoring functions such as abnormal mains power, power failure, battery capacity, UPS status indication, etc | Options | SNMP card, AS400 card, USB communication | Operating environment | temperature | 0℃~40℃ | humidity | 20%~90% | The overall dimensions of the host (W×D×H) mm | 482.6x450x88 | 482.6x600x130 | Exterior dimensions of the battery pack (W×D×H) mm | 482.6x450x88 | 482.6x600x130 | The weight of the main engine (net weight) kg | 16.3 | 9.1 | 10.3 | 11.5 | 11.2 | 12.3 | 18.3 | 18.5 | 19.2 | 19.5 |
The above is the product introduction of EATON/Eaton UPS Power Supply Online Rack Type C1KR, this product introduction is: a wide range of input voltage and frequency, so that Rack UPS can be used with major brands of generators, the use time is longer, and at the same time, the bad power generated by the generator is effectively removed, providing pure, safe and stable power supply for the load.
All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original genuine products, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, save money.
|
More on that
|
EATON UPS Power Supply Online Double Conversion Marine Type 9PHD-60-M
Product introduction of 9PHD-60-M: This series of UPS is mainly used to protect the network equipment of emergency lighting systems, emergency public address systems, computer and communication systems, ship automation control systems and other applications of ships or offshore platforms.
Eaton UPS:
Eaton 935 ...
|
|
The EATON/Eaton UPS 9155 Marine Marine UPS is small
Eaton 9155 Marine Product Brief: The 9155 Marine UPS is a series of on-line, double-conversion marine UPSs that provide users with a single-in, single-out, or triple-in, single-output high-efficiency uninterruptible power supply with an output capacity of 8–30 kVA. This series of UPS is mainly used to protect ships or ...
|
|
EATON UPS Power Supplies Tower/Rack 9PX 11KVA Rated Capacity 11KVA
9PX 11KVA Product Introduction: Input Frequency Range 40-70Hz, 50/60Hz Input Harmonics Input Current Harmonics: THDI<5% Output Voltage Range 200/208/220/230/240V±1%V Other Input Parameters Frequency Range: Automatic Selection, Selectable Frequency Conversion Mode Other Output Parameters
|
|
EATON UPS Power Supply Online 9355-10-NC-0 Rated Capacity 10KVA
Product Brief of 9355-10-NC-0: Output Voltage Range 220/380, 230/400, 240/415 VAC/±20%V Output Frequency Range 50/60Hz Product Weight 165Other Features Operating temperature 0°C - 40°C.
Eaton UPS:
The above is EATON/Eaton UPS power supply ...
|
|
EATON UPS Power Supply Online 9E-160K Rated Capacity 160KVA
Product Brief of 9E-160K: Input Voltage Range -45-25%, 380V/220V Input Frequency Range -45-65Hz Battery Type VRLA, AGM, Gel Battery, or Eaton's Designated Brand and Model Battery Capacity 36×12VDC (Adjustable) Charging Time ...
|
|
EATON UPS Power Supply Online 9E-100K Input Voltage Range 45-25%, 380V/220V
Product Brief for 9E-100K: Backup Time Minutes depending on battery pack capacity Battery Type VRLA AGM, gel batteries, or batteries specified by Eaton Battery capacity 36×12VDC (adjustable) Charging time 8 hours to reach 90% full capacity.
Eaton UPS:
...
|
|
EATON UPS Power Supply RT2U Tower/Rack 5PX 1.5KVA Rated Capacity 1.5KVA
Product Brief of 5PX 1.5KVA: Rated Power 1350W Output Socket Input: (1) IEC C14 (10A) Socket Output: (8) IEC C13 (10A) Remote Control Socket: 2 sets of 2×IEC C13 (10A) Hot-swap Maintenance Bypass Module Additional Output Socket: 4 FR/Schuko Socket or ...
|
|
EATON/EATON 9SX Series UPS 9SX20KPMCH RATED POWER 15K-20KVA
Product Brief for 9SX20KPMCH:[/backcolor] Improves dual conversion efficiency and reduces size, helping users reduce electricity bills and save rack space costs. The UPS input and output can be compatible with both single-phase and three-phase power distribution, which improves the adaptability of different industry applications.
Eaton UPS:
...
|
|
EATON UPS Power Supply EDX10KHXL UPS Double Conversion Type
EDX10KHXL Product Introduction: The E-Series DX adapts to a wide range of input voltages, avoiding the use of battery discharge during slight power fluctuations, and saving battery power for use when power is completely lost from the grid.
Eaton UPS:
Eaton UPS Power Supply EDX10KHXL Technical Specifications ...
|
|
EATON UPS Power Supply On-line, Tower EDX1000C Output frequency range 50/60Hz
EDX1000C Product Introduction: Interface Port Standard RS232, SNMP Card (Option) Alarm Function Battery Mode Operation, Low Battery, General Fault, Overload, Bypass On/Off, Auto Start, Cold Start, Buzzer Off Protection Data Line: Included for Telephone/Modem ...
|
|
Eaton UPS Power Supply In-line Double Conversion Marine Type 9155-8-S-TM
Product introduction of 9155-8-S-TM: This series of UPS is mainly used to protect the network equipment of emergency lighting systems, emergency public address systems, computer and communication systems, ship automation control systems and other applications on ships or offshore platforms.
Eaton UPS:
Eaton 9155 Marine ...
|
|
Eaton UPS 9SX3000i Built-in Battery/External Battery Pack - Eaton Eaton UPS Power Supply in United States
|
|
EATON Eaton 9355 Marine UPS 9395-550-M
9395-550-M Product Introduction:This series of UPS is mainly used to protect the network equipment of emergency lighting systems, emergency public address systems, computer and communication systems, ship automation control systems and other applications of ships or offshore platforms.
Eaton UPS:
Core features
...
|
|
EATON UPS Power Supply Online 9355-15-NC-0 Rated Power 15W
Product Brief for 9355-15-NC-0: Output Voltage Range 220/380, 230/400, 240/415 VAC/±20%V Output Frequency Range 50/60Hz Battery Type Maintenance-free VRLA battery.
Eaton UPS:
The above is ...
|
|
EATON UPS Power Supply Online DX RT 10KVA Ext Rated Capacity 10KVA
DX RT 10KVA Ext Product Introduction:Output Voltage Range 200/208/220/230/240VAC (220VAC Missing) ±2%V Output Frequency Range (Battery Mode) 50±0.05Hz Output Power 0.9 Other Output Parameters Voltage Distortion: ...
|
|
EATON UPS Power Supply Online and Tower Rack Dual-purpose 9130 1000VA Tower
9130 1000VA Tower Product Introduction: Input Voltage Range (Nominal 220-240) 180-276V Input Frequency Range 45-65Hz Output Power 0.9 Other Input Parameters Nominal Current: 4.3A, 230V Rated Circuit Breaker: 10A.
Eaton UPS:
The above is EATON/...
|
|
Eaton UPS Power EX Series EX RT15002U Pulsar
EX RT15002U Product Description: Power class 700-3000 VA Rated voltage 220-240V frequency 50/60 Hz Configuration Rack/Tower product family Pulsar.
Eaton UPS:
The above is EATON/EA
|
|
EATON UPS Power Supply Online Rack Type C2KR Voltage (110~300)VAC
C2KR Product Introduction: In order to prevent users from letting the UPS work in BYPASS MODE (bypass mode) without turning on the use, resulting in mains power interruption and abnormal shutdown of the UPS and equipment. Input normal mains, no bypass output by default. It must be turned on to have normal inverter output. But it can be done with Win...
|
|
EATON UPS Power Supply EDX15KHXL31 UPS Double Conversion Type
EDX15KHXL31 Product Introduction: The E-Series DX adapts to a wide input voltage range, avoiding the use of battery discharge during slight power fluctuations, and saving battery power for use when power is completely lost from the grid.
Eaton UPS:
Eaton UPS EDX15KHXL31 Technical Indicators ...
|
|
EATON UPS Power Supply On-line, Tower EDX10KCXL31 Output voltage range 380/220V
EDX10KCXL31 Product Introduction: Interface Port Standard RS232, SNMP Card (Option) Alarm Function Battery Mode Operation, Low Battery, General Fault, Overload, Bypass On/Off, Auto Start, Cold Start, Buzzer Off Protection Data Line: Included for Telephone/Modem ...
|
|