Product Brief Introduction of 9PX 2.2KVA: Output Socket Input: (1) IEC C20 (16A), Output: (8) IEC C13 (10A) + (2) IEC C19 (16A) Maintenance Bypass Output via Hotswap Maintenance: (6) IEC 10A Socket 2 Switch Socket Group Efficiency Mains Mode: Up to 93.5% (Up to 98% in Highest Efficiency Mode).
Eaton UPS:
Basic parameters | UPS type | Tower/Rackmount | Rated capacity | 2.2KVA | Rated power | 2200W | Rated voltage | 200/208/220/230/240V | Output socket | Input: (1) IEC C20 (16A), Output: (8) IEC C13 (10A) + (2) IEC C19 (16A)
Maintenance bypass output via Hotswap: (6) IEC 10A socket
2 switch socket groups | Overall machine efficiency | Mains mode: up to 93.5% (up to 98% in maximum efficiency mode) |
Input and output parameters | Input voltage range | No derating (up to 100-276V when derating), 176-276V | Enter the frequency range | 40-70Hz,50/60Hz | Other input parameters | Frequency range: automatic selection, frequency conversion mode |
Communications and Management | Interface port | RS-232, USB port, remote on/off terminals, remote power-off terminals, output dry-node terminals, install network-MS card, Modbus-MS card or dry-node-MS card slot |
Battery and runtime | Backup time | Minutes depending on the capacity of the battery pack |
environment | Working environment | Operating temperature: 0-40°C | Noise level (dBA) | 40dB(A) |
Other parameters | Light | Graphical LCD display in multiple languages | Exterior dimensions | 86.5×440×605mm | Product weight | 25kg | Other features | Technology: In-line double conversion system with power factor correction (PFC).
Battery Management: ABM® & Temperature Compensated Charging Method (User Optional), Automatic Battery Testing, Deep Discharge Protection, Automatic Identification of External Battery Pack
Safety: IEC/EN 62040-1, UL 1778, CSA 22.10
Electromagnetic compatibility: IEC/EN 62040-2, FCC Class B, CISPR22 Class B
Licensing & Marking: CE/CB Report (TUV)/cULus/EAC/RCM/KC/EnergyStar |
The above is the product introduction of ATON/Eaton UPS Power Supply Tower/Rack 9PX 2.2KVA, this product introduction is: Output Socket Input: (1) IEC C20 (16A), Output: (8) IEC C13 (10A) + (2) IEC C19 (16A) Maintenance bypass Output via Hotswap: (6) IEC 10A socket 2 switch socket group efficiency Mains mode: up to 93.5% (up to 98% in maximum efficiency mode).
All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original genuine products, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, save money.
|
More on that
|
EATON UPS Power Supply On-line, Tower EDX10KCXL31 Output voltage range 380/220V
EDX10KCXL31 Product Introduction: Interface Port Standard RS232, SNMP Card (Option) Alarm Function Battery Mode Operation, Low Battery, General Fault, Overload, Bypass On/Off, Auto Start, Cold Start, Buzzer Off Protection Data Line: Included for Telephone/Modem ...
|
|
EATON UPS Power Supply Inline, Tower Rackmount Dual-Purpose DX RT 2KVA Std
DX RT 2KVA Std Product Introduction:Output Voltage Range 200/208/220/230/240 (Default 220V)±2%V Output Frequency Range (Battery Mode)50±0.05HzOutput Power 0.9Other Output Parameters Voltage Distortion: ...
|
|
EATON/Eaton 93 Series UPS 93PR-75-STD input capacity 25-75KVA
Product Brief for the 93PR-75-STD: This UPS meets the power assurance requirements of network equipment in wiring closets, small and medium-sized data centers, large data centers, automation or medical applications.
Eaton UPS:
Core features
High scalability
...
|
|
EATON/Eaton DX UPS 1–20 kVA DX UPS Telecommunications
1–20 kVA Product Introduction: Online double conversion topology, filter out all kinds of interference in the power grid, provide the purest power supply for critical loads The output power factor is 0.9, which provides 28% more effective power than other low power factor UPS input power factor >0.99, reducing the impact on the power grid.
|
|
EATON UPS Power Supply Online 9E-60K Input Frequency Range -45-65Hz
Product Brief Introduction of 9E-60K: Working Environment Operating Temperature: 0-40°C, Storage Temperature: -25-55°C, Relative Humidity: 5-95% Noise Level (dBA)
|
|
Eaton UPS Power Supply Online Rack Type C1KRS Voltage (110~300)VAC
C1KRS product introduction: the bypass power supply function greatly strengthens the emergency handling ability of UPS, and at the same time, when the user's load equipment has special requirements for the power supply, such as the voltage can not be too high, UPS provides bypass power supply voltage too high protection, so that the user's load equipment is free from high voltage danger.
He...
|
|
EATON UPS Power Supply Rackmount (1U) 5P 650iR Power Rating 420W
Product introduction of 5P 650iR: Input voltage range 160-294V, adjustable to 150-294V input frequency range 50Hz system: 47-70Hz60Hz system: 56.5-70Hz Low sensitivity mode 40Hz output voltage range 230V (+6/-10%), adjustable to 200/208/220/230/240V.
...
|
|
Eaton UPS Power Supply Inline, Tower EX 700VA Tower
EX 700VA Tower Product Introduction: Output Voltage Range (Adjustable to 200/208/220/240/250) 230V Output Frequency Range 50/60Hz Other Input Parameters Dual with 1 IEC C14 (10A) Socket Other Output Parameters Equipped with 6 IEC ...
|
|
Eaton/Eaton UPS Power EX 1000VA 2U Rack/Tower 18kg
EX 1000VA 2U Rack/Tower Product Introduction: Interface Ports 1 USB port + 1 RS232 serial interface + 1 set of remote on/off and emergency shutdown signal terminals Panel display 3 LED indicators + adjustable multi-language display.
Eaton UPS:
The above is the EAT...
|
|
EATON UPS Power Supply Online Double Conversion Marine Type 9PHD-60-M
Product introduction of 9PHD-60-M: This series of UPS is mainly used to protect the network equipment of emergency lighting systems, emergency public address systems, computer and communication systems, ship automation control systems and other applications of ships or offshore platforms.
Eaton UPS:
Eaton 935 ...
|
|
EATON UPS Power Supply Online 9E-160K Rated Capacity 160KVA
Product Brief of 9E-160K: Input Voltage Range -45-25%, 380V/220V Input Frequency Range -45-65Hz Battery Type VRLA, AGM, Gel Battery, or Eaton's Designated Brand and Model Battery Capacity 36×12VDC (Adjustable) Charging Time ...
|
|
EATON UPS Power Supply On-line, Tower EDX1000C Output frequency range 50/60Hz
EDX1000C Product Introduction: Interface Port Standard RS232, SNMP Card (Option) Alarm Function Battery Mode Operation, Low Battery, General Fault, Overload, Bypass On/Off, Auto Start, Cold Start, Buzzer Off Protection Data Line: Included for Telephone/Modem ...
|
|
EATON UPS Power Supply Online 9355-10-NC-0 Rated Capacity 10KVA
Product Brief of 9355-10-NC-0: Output Voltage Range 220/380, 230/400, 240/415 VAC/±20%V Output Frequency Range 50/60Hz Product Weight 165Other Features Operating temperature 0°C - 40°C.
Eaton UPS:
The above is EATON/Eaton UPS power supply ...
|
|
Eaton UPS Power Supply Inline, Tower Rack Dual-Purpose EX 3000 2U Rack/Tower
EX 3000 2U Rack/Tower Product Introduction: Input Voltage Range 100/120/160/184-284V Input Frequency Range 40-70Hz Output Voltage Range (Adjustable to 200/208/220/240) 230V Output Frequency Range 50/60Hz Other Input Parameters Equipped with 1 IEC C20 ...
|
|
Eaton UPS Power EDX1000H E Series DX UPS Double Conversion Type
EDX1000H Product Introduction: The E-Series DX adapts to a wide input voltage range, avoiding the use of battery discharge during slight power fluctuations, and saving battery power for use when power is completely lost from the grid.
Eaton UPS:
E Series DX (1-20kVA) Specifications Battery operation ...
|
|
EATON/EATON 9SX Series UPS 9SX20KPMCH RATED POWER 15K-20KVA
Product Brief for 9SX20KPMCH:[/backcolor] Improves dual conversion efficiency and reduces size, helping users reduce electricity bills and save rack space costs. The UPS input and output can be compatible with both single-phase and three-phase power distribution, which improves the adaptability of different industry applications.
Eaton UPS:
...
|
|
EATON UPS Power Supply Rack/Tower Interchange 9SX20KPMCH
Product Brief Introduction of 9SX20KPMCH: This product uses advanced technology to improve double conversion efficiency and reduce size, which helps users reduce electricity bills and save rack space costs. The UPS input and output can be compatible with both single-phase and three-phase power distribution, which improves the adaptability of different industry applications. Large size ...
|
|
EATON Eaton 9355 Marine UPS 9395-550-M
9395-550-M Product Introduction:This series of UPS is mainly used to protect the network equipment of emergency lighting systems, emergency public address systems, computer and communication systems, ship automation control systems and other applications of ships or offshore platforms.
Eaton UPS:
Core features
...
|
|
EATON UPS Power Supply Tower/Rack 9PX 1KVA Rated Power 1000W
Product introduction of 9PX 1KVA: Rated power 1000W rated voltage 200/208/220/230/240V output socket Input: (1) IEC C14 (10A), Output: (8) IEC C13 (10A) Maintenance bypass output via Hotswap: (6) IEC 10A socket 2 switch socket sets Whole machine efficiency ...
|
|
Eaton UPS Power Supply DX-RT Series 9103-53492-00P
9103-53492-00P Product Introduction: With an output power factor of up to 0.9, the Eaton DX RT provides a more powerful load capacity, matching with modern computer equipment that has widely used input power factor correction circuits, and has small input harmonics and is environmentally friendly.
Eaton...
|
|