Schneider _LC1E0601E5N_ contactors prevent overloading of circuits

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Product Description
LC1E0601E5N Introduction: Schneider Electric Contactors, LC1E Series, 3 TeSys E

Schneider/Schneider_LC1E0601E5N

Schneider/Schneider LC1E0601E5N


Model features introduced

Contactor LC1E series
LC1-E series AC contactors are mainly used in circuits with 50Hz (or 60Hz) AC current and 690V rated insulation voltage. These contactors can also be used in utilization category AC-3 circuits with a rated voltage of 380V and an operating current rating of up to 95A. These contactors provide long-distance connection and circuit break capabilities. These contactors can also be combined with suitable thermal overload relays to form electromagnetic starters to prevent possible overloads in the circuit. A contactor consists of three main systems: an electromagnetic system, a contact system, and an interjector system, among other components. (1) Electromagnetic system: The electromagnetic system includes a magnetic coil and an iron core, which is an important part of the contactor and is used to drive the closing and disconnection of the contact. (2) Contact system: The contact is the operating part of the contactor, mainly including the contact and the auxiliary contact. The basic function of the main contact is to connect and disconnect the main circuit and control high currents. Auxiliary contacts are part of the control loop and are used to meet the requirements of various control methods. (3) Interrupter system: The interrupter equipment is used to ensure that the arc generated when the contact is broken is extinguished, so as to reduce the damage caused by the arc to the contact. In order to quickly extinguish the arc caused by the open circuit, the contactor is usually fitted with a blocker device. Typically, semi-sealed clay stopper covers are used in conjunction with a magnetic blow-out circuit. (4) Other components: insulated shell and spring, short-circuit ring and transmission mechanism.

SchneiderElectricTeSysE series


Model parameters are introduced

attributenumeric value
rangeTeSysE
seriesLC1E
Number of poles3


All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original genuine products, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, save money.

The above is the France brand Schneider / Schneider model for the LC1E0601E5N products, the introduction of this product is: Schneider Electric Schneider contactor, LC1E series, 3 TeSys E, the purpose of 76 technology is to survive by quality, develop by reputation, and eternal by service, give us a chance, and give you a surprise.
More on that
Schneider _LC1F3304U7_ Contactor 4 NO contact -5°C Schneider _LC1F3304U7_ Contactor 4 NO contact -5°C

LC1F3304U7 Introduction: Schneider Electric Contactors, LC1F Series, 4, min. -5°C TeSys F, 4 NO contacts Schneider/Schneider_LC1F3304U7 Model features introduced Model parameters are introduced 76 Technology ...

Schneider _ZBE1016_ button attachment single contact block Schneider _ZBE1016_ button attachment single contact block

ZBE1016 Profile: Schneider Electric Contact Block, Harmony XB Series, Single Channel, Used in XB4 Series, XB5 Series Schneider/Schneider_ZBE1016 Model features introduced Harmony Contact Block Directly assembled in the ...

Schneider _LADN10_ auxiliary contacts Screw end 1 contact Schneider _LADN10_ auxiliary contacts Screw end 1 contact

LADN10 Introduction: Schneider Electric Auxiliary Contact Block, LADN Series, 1 Contact, Screw End Front Mount, Normally Open Schneider/Schneider _LADN10 Model features introduced Auxiliary contact blocks For use with contactors or control relays. Forehead...

Schneider _LC1K1601P72_ contactor 230 V AC 16 A Schneider _LC1K1601P72_ contactor 230 V AC 16 A

LC1K1601P72 Introduction: Schneider Electric contactor, LC1K series, 230 V AC coil, 16 A, 3, minimum operating temperature -25°C TeSys K Schneider/Schneider _LC1K1601P72 Model features introduced Model Parameters Introduction ...

Schneider_LC1D1150046BD_ Contactor 4 NO contacts Schneider_LC1D1150046BD_ Contactor 4 NO contacts

LC1D1150046BD Introduction: Schneider Electric contactors, LC1D series, 24 V DC coils, 115 A, 4 Tesys D, 4 NO contacts Schneider/Schneider _LC1D1150046BD Model features introduced 4-pole contactor, DC controlled ...

Schneider _LP1K1210BD_ silent miniature contactor 24 V 12 A Schneider _LP1K1210BD_ silent miniature contactor 24 V 12 A

LP1K1210BD Introduction: Schneider Electric contactors, LP1K series, 24 V DC coil, 12 A, 3, minimum operating temperature -25°C TeSys K Schneider/Schneider _LP1K1210BD Model features introduced SchneiderElectricLP ...

Schneider _LC1K1610FE7_ contactor 110 V 16 A 3 normally open Schneider _LC1K1610FE7_ contactor 110 V 16 A 3 normally open

LC1K1610FE7 Introduction: Schneider Electric contactors, LC1K series, 110 V AC coil, 16 A, 3 TeSys K, 3 NO contacts Schneider/Schneider _LC1K1610FE7 Model features introduced Model parameters are introduced Seventy-six ...

Schneider _LC2DT32Q7_ contactors 400 V minimum operating temperature -5°C Schneider _LC2DT32Q7_ contactors 400 V minimum operating temperature -5°C

LC2DT32Q7 Introduction: Schneider Electric Contactors, LC2D Series, 400 V AC Coil, 4, min. -5°C Tesys D Schneider/Schneider _LC2DT32Q7 Model features introduced Model parameters are introduced Seven or six ...

Schneider_ATS01N209QN Soft-start 4kW three-phase input controllable deceleration Schneider_ATS01N209QN Soft-start 4kW three-phase input controllable deceleration

ATS01N209QN Introduction: Schneider Electric ATS01 Series 9 A 3-phase soft starter ATS01N209QN, IP20, 4 kW, 380 → 415 V Schneider/Schneider _ATS01N209QN Model features introduced Altistart soft start with soft stop – 40 ...

Schneider_HMIGBPACSCU8NT_ touch screen HMI display Schneider_HMIGBPACSCU8NT_ touch screen HMI display

HMIGBPACSCU8NT Description: Schneider Electric HMISCU TFT 5.7 in Color Touchscreen HMI Starter Kit with Backlight, 320 x 240pixels Schneider/Schneider _HMIGBPACSCU8NT Model features introduced HMISCU-HMI Control ...

Schneider _LC2D115Q7_ contactor 400 V cable Schneider _LC2D115Q7_ contactor 400 V cable

LC2D115Q7 Introduction: Schneider Electric Contactors, LC2D Series, 400 V AC Coil, 3, min. -5°C Tesys D Schneider/Schneider _LC2D115Q7 Model features introduced Model parameters are introduced Seven or six ...

Schneider _LC1D150ND_ Contactors LC1D Series 3 NO Schneider _LC1D150ND_ Contactors LC1D Series 3 NO

LC1D150ND Introduction: Schneider Electric Contactors, LC1D Series, 3, min. -5°C Tesys D, 3 NO contacts Schneider/Schneider _LC1D150ND Model parameters are introduced All suppliers of 76 Technology have been strictly vetted ...

Schneider _LP1K12105JD_ contactor 12 V DC coil 20 A Schneider _LP1K12105JD_ contactor 12 V DC coil 20 A

LP1K12105JD Introduction: Schneider Electric contactor, LP1K series, 12 V DC coil, 20 A, 3, minimum operating temperature -25°C TeSys K Schneider/Schneider _LP1K12105JD Model features introduced Model parameters are introduced ...

Schneider _LC2D50ABD_ contactor cable 24 V DC coil Schneider _LC2D50ABD_ contactor cable 24 V DC coil

LC2D50ABD Introduction: Schneider Electric contactors, LC2D series, 24 V DC coils, 3, min. -5°C Tesys D Schneider/Schneider _LC2D50ABD Model features introduced Model parameters are introduced 76 Technology ...

Schneider_SR2A201BD_ Logic Modules Relay outputs are compact Schneider_SR2A201BD_ Logic Modules Relay outputs are compact

SR2A201BD Introduction: Schneider Electric logic module, relay output, 12 x input, 8 x output, 24 V DC, 124.6 x 107.6 x 59.5 mm Schneider/Schneider _SR2A201BD Model features introduced Zelio Logic Smart Relays - ...

Schneider _LC2K0910N7_ reversible contactor screw clamp termination Schneider _LC2K0910N7_ reversible contactor screw clamp termination

LC2K0910N7 Introduction: Schneider Electric Reversible Contactor, LC2K Series, 400 V AC Coil, 9 A, 3 TeSys K, 3 NO contacts Schneider/Schneider _LC2K0910N7 Model features introduced 3-pole reverse contactor with screw clamp

Schneider _LC1D40AB7_ contactors Built-in auxiliary contacts Schneider _LC1D40AB7_ contactors Built-in auxiliary contacts

LC1D40AB7 Introduction: Schneider Electric Contactors, LC1D Series, 24 V AC Coil, 40 A, 3, min. -5°C Tesys D Schneider/Schneider _LC1D40AB7 Model features introduced SchneiderElectricLC1DT ...

Schneider _LC8K0601M7_ Contactor 230 V 6 A 3 NO Schneider _LC8K0601M7_ Contactor 230 V 6 A 3 NO

LC8K0601M7 Introduction: Schneider Electric contactors, LC8K series, 230 V AC coil, 6 A, 3, min. -25°C TeSys K Schneider/Schneider _LC8K0601M7 Model features introduced Model parameters are introduced ...

Schneider/Schneider _LP1K12013BD_ contactors 24 V DC 20 A Schneider/Schneider _LP1K12013BD_ contactors 24 V DC 20 A

LP1K12013BD Introduction: Schneider Electric contactors, LP1K series, 24 V DC coil, 20 A, 3, min. -25°C TeSys K Schneider/Schneider _LP1K12013BD Model features introduced Model parameters are introduced ...

Schneider _RXM021RB relay protection module socket Schneider _RXM021RB relay protection module socket

RXM021RB Introduction: Schneider Electric relay protection module for a wide range of 6 → 24V ac/dc voltages Schneider/Schneider _RXM021RB Model features introduced Brackets and accessories for RXM series relays Available in a range of brackets and ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top