LC1E3810E5N Introduction: Schneider Electric Contactors, LC1E Series, 3 TeSys E
Schneider/Schneider _LC1E3810E5N
Model features introduced
Contactor LC1E series
LC1-E series AC contactors are mainly used in circuits with 50Hz (or 60Hz) AC current and 690V rated insulation voltage. These contactors can also be used in utilization category AC-3 circuits with a rated voltage of 380V and an operating current rating of up to 95A. These contactors provide long-distance connection and circuit break capabilities. These contactors can also be combined with suitable thermal overload relays to form electromagnetic starters to prevent possible overloads in the circuit. A contactor consists of three main systems: an electromagnetic system, a contact system, and an interjector system, among other components. (1) Electromagnetic system: The electromagnetic system includes a magnetic coil and an iron core, which is an important part of the contactor and is used to drive the closing and disconnection of the contact. (2) Contact system: The contact is the operating part of the contactor, mainly including the contact and the auxiliary contact. The basic function of the main contact is to connect and disconnect the main circuit and control high currents. Auxiliary contacts are part of the control loop and are used to meet the requirements of various control methods. (3) Interrupter system: The interrupter equipment is used to ensure that the arc generated when the contact is broken is extinguished, so as to reduce the damage caused by the arc to the contact. In order to quickly extinguish the arc caused by the open circuit, the contactor is usually fitted with a blocker device. Typically, semi-sealed clay stopper covers are used in conjunction with a magnetic blow-out circuit. (4) Other components: insulated shell and spring, short-circuit ring and transmission mechanism.
SchneiderElectricTeSysE series
Model parameters are introduced
attribute | numeric value | range | TeSysE | series | LC1E | Number of poles | 3 |
All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original genuine products, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, save money.
The above is the France brand Schneider/Schneider model for the LC1E3810E5N products, the introduction of this product is: Schneider Electric Schneider Contactor, LC1E Series, 3 TeSys E, the purpose of 76 Technology is to survive by quality, develop by reputation, and eternal by service, give us a chance and give you a surprise.
|
More on that
|
Schneider/Schneider _LP1D65008ND_ Contactor 4P 60 V DC cable
LP1D65008ND Introduction: Schneider Electric Contactors, LP1D Series, 60 V DC Coil, 4, min. -5°C Tesys D
Schneider/Schneider _LP1D65008ND
Model features introduced
Model parameters are introduced
Seventy-six ...
|
|
Schneider _LC1D50A6ND_ Contactor 3 NO contacts
LC1D50A6ND Introduction: Schneider Electric contactors, LC1D series, 3, min. -5°C Tesys D, 3 NO contacts
Schneider/Schneider _LC1D50A6ND
Model features introduced
Model parameters are introduced
76 Technology ...
|
|
Schneider _LC1DT80A6FC7_ contactors 4 NO contacts
LC1DT80A6FC7 Introduction: Schneider Electric Contactors, LC1D Series, 4, min. -5°C Tesys D, 4 NO contacts
Schneider/Schneider_LC1DT80A6FC7
Model features introduced
Model parameters are introduced
Seventy-six ...
|
|
Schneider _LC1D80008N7_ contactors 2 NO / 2 NC contacts
LC1D80008N7 Introduction: Schneider Electric Contactors, LC1D Series, 4, min. -5°C Tesys D, 2 NO/2 NC contacts
Schneider/Schneider _LC1D80008N7
Model features introduced
Model parameters are introduced
...
|
|
Schneider _RXM021RB relay protection module socket
RXM021RB Introduction: Schneider Electric relay protection module for a wide range of 6 → 24V ac/dc voltages
Schneider/Schneider _RXM021RB
Model features introduced
Brackets and accessories for RXM series relays
Available in a range of brackets and ...
|
|
Schneider _LC1D40008Z7_ Contactor 2 NO/2 NO
LC1D40008Z7 Introduction: Schneider Electric Contactors, LC1D Series, 4, min. -5°C Tesys D, 2 NO/2 NC contacts
Schneider/Schneider _LC1D40008Z7
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LC1D12EL_3 pole DC control contactors
LC1D12EL Introduction: Schneider Electric Contactors, LC1D Series, 48 V DC Coil, 12 A, 3 Tesys D, 3 NO contacts
Schneider/Schneider _LC1D12EL
Model features introduced
3-pole DC controlled contactor
Built-in coil suppression 3 ...
|
|
Schneider_LC1K090045E7_ contactor 48 V 20 A
LC1K090045E7 Introduction: Schneider Electric contactors, LC1K series, 48 V AC coil, 20 A, 4, minimum operating temperature -25°C TeSys K
Schneider/Schneider _LC1K090045E7
Model features introduced
Model Parameters ...
|
|
Schneider _LP1K0910ND3_ contactors 60 V 20 A LP1K series
LP1K0910ND3 Introduction: Schneider Electric contactors, LP1K series, 60 V DC coil, 20 A, 3, min. -25°C TeSys K
Schneider/Schneider _LP1K0910ND3
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LC1E0910E5N_ contactor 690V 3-pole electromagnetic system
LC1E0910E5N Introduction: Schneider Electric Contactors, LC1E Series, 3 TeSys E
Schneider/Schneider _LC1E0910E5N
Model features introduced
Contactor LC1E series
LC1-E series AC contactors are mainly used for applications with 50Hz (or 60Hz...
|
|
Schneider _LC1D40A6L7_ contactor 440 V AC 40 A
LC1D40A6L7 Introduction: Schneider Electric contactors, LC1D series, 440 V AC coil, 40 A, 3, min. -5°C Tesys D
Schneider/Schneider_LC1D40A6L7
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LC1DT40MD_ Contactors 4-pole contactor, DC controlled
LC1DT40MD Introduction: Schneider Electric contactors, LC1D series, 230 V DC coil, 40 A, 4 Tesys D, 4 NO contacts
Schneider/Schneider_LC1DT40MD
Model features introduced
4-pole contactor, DC controlled
Use the category ...
|
|
Schneider AC Contactor LC1-D09M7C AC220V
Introduction: LC1-D09M7C AC connector is mainly used for AC 50H or 60Hz, AC voltage to 660V (690V), when the working voltage is 220V under the AC-3 use category, the rated working current is 9A in the circuit, for keeping away from the connection and breaking circuits, and can be used with the corresponding specifications of ...
|
|
Schneider _LRD05_ contactors and thermal overload relays with three poles
LRD05 Introduction: Schneider Electric Thermal Overload Relay LRD0 Series, 0.63 → 1 A, contact current rating 1 A
Schneider/Schneider_LRD05
Model features introduced
Three-pole thermal overload relay
Three-pole thermal overload relay design ...
|
|
Schneider/Schneider _LC7K09107F7_ contactor 110 V 20 A 3 TeSys K
LC7K09107F7 Introduction: Schneider Electric contactors, LC7K series, 110 V AC coil, 20 A, 3 TeSys K, 3 NO contacts
Schneider/Schneider _LC7K09107F7
Model features introduced
Model parameters are introduced
Seventy-six ...
|
|
Schneider _LC1D12PD_ contactor 110 V DC coil
LC1D12PD Introduction: Schneider Electric contactors, LC1D series, 110 V DC coil, 25 A, 3, min. -5°C Tesys D
Schneider/Schneider _LC1D12PD
Model features introduced
Model parameters are introduced
Seven...
|
|
Schneider _LC2DT25P7_4 Polar Reverse Contactor 25 A 230 V
LC2DT25P7 Introduction: Schneider Electric contactor, LC2D series, 230 V AC coil, 25 A, 4, min. -25°C Tesys D
Schneider/Schneider _LC2DT25P7
Model features introduced
4-pole reverse contactor
Screw...
|
|
Schneider _LC8K0601M7_ Contactor 230 V 6 A 3 NO
LC8K0601M7 Introduction: Schneider Electric contactors, LC8K series, 230 V AC coil, 6 A, 3, min. -25°C TeSys K
Schneider/Schneider _LC8K0601M7
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LC2DT20E7_ contactor 48 V AC coil
LC2DT20E7 Introduction: Schneider Electric contactors, LC2D series, 48 V AC coils, 4, minimum operating temperature -5°C Tesys D
Schneider/Schneider _LC2DT20E7
Model features introduced
Model parameters are introduced
76 Technology ...
|
|
Schneider _LC1DT206E7_ contactor 4 NO contacts
LC1DT206E7 Introduction: Schneider Electric Contactors, LC1D Series, 4, min. -5°C Tesys D, 4 NO contacts
Schneider/Schneider_LC1DT206E7
Model features introduced
Model parameters are introduced
76 Technology ...
|
|