Introduction: Schneider LC1-D80 AC Contactor When the contactor electromagnetic coil is not energized, the reaction force of the spring and the self-weight of the armature core keep the main contact in the open position. When the electromagnetic coil is connected to the control voltage (generally the rated voltage) through the control loop, the electromagnetic force overcomes the reaction force of the spring and sucks the armature to the static iron core, driving the main contact to close, turning on the circuit, and the auxiliary contact to act.
Product parameters
Product family: TeSys
Product name: D
Product Type: Contactor
Short name: LC1D
Contactor Applications:
It should be used in AC loads with a power factor greater than or equal to 0.95
It should be used to turn on and break the squirrel cage motor that starts normally
Categories of use:
AC-1
AC-3
AC-4
Number of poles: 3P
Main contact type: 3 NO
Rated operating current[le]:
80 A(AC-1.Ues= 440 V e= 60C
125 A(AC-3.Uec= 440 e= 60C)
Control loop voltage: 220 V AC 50/60 Hz
Auxiliary contact type: 1 NO +1 NC
Rated operating voltage [Ue]:
Power Circuit: = 690 V
Power circuit: < = 300 V
Motor power(kw):
55 kW (500 V) AC-3
45 kW (1000 V) AC-3
22 kW (220/240 V) AC-3
37 kW (380/400 V) AC-3
45 kW (415/440 V) AC-3
45 kW (660/690 V) AC-3
15 kW (400 V) AC-4
Electrical Life:
0.8 kA2.s(AC-1)
1.5 kA2.s (AC-3)
2.5 kA2 s(40-3)
Mechanical life: 4 kA².S
Maximum operating frequency: 3600 hours (ambient temperature e= 60°C)
Action time
Closed: 20... 35 ms
Break::6... 20 ms
Control voltage limits
Release: 0.3... 0.6 Uc 50/60 Hz
Run: 0.8... 1.1 Uc 50 Hz
Height: 127mm
Width: 85mm
Depth: 130mm
Control loop characteristics: AC 50/60 Hz
Rated impulse withstand voltage [Uimp]: 8 kV (IEC 60947)
Product weight: 1.59 kg
The company respects the enterprise spirit of "practicality, hard work and responsibility", and creates a good corporate environment with integrity, win-win, and business philosophy, and takes a new management model, perfect technology, thoughtful service, and excellent quality as the foundation for survival. We always adhere to: customer first, serve customers attentively, and insist on impressing customers with their own services. Always adhering to the business philosophy of "integrity, win-win", relying on excellent prices, excellent quality, fast delivery and pre-sales consultation and after-sales service to win the trust of our customers.
This article introduces Schneider AC contactor LC1-D80 3P 3NO products, if you are interested in Schneider AC contactor, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Schneider _LC1D50AU7_ Contactor 230 V 50 A 3 NO
LC1D50AU7 Introduction: Schneider Electric contactors, LC1D series, 230 V AC coils, 50 A, 3 Tesys D, 3 NO contacts
Schneider/Schneider _LC1D50AU7
Model features introduced
SchneiderElectricLC1DTeSysD ...
|
|
Schneider _LRD12_ contactors and thermal overload relays 8 A
LRD12 Introduction: Schneider Electric Thermal Overload Relay LRD1 Series, 5.5 → 8 A, contact current rating 8 A
Schneider/Schneider _LRD12
Model features introduced
Three-pole thermal overload relay
Three-pole thermal overload relay design ...
|
|
Schneider _LC1D65008FE7_ contactors 2 NO/2 NO
LC1D65008FE7 Introduction: Schneider Electric Contactors, LC1D Series, 4, min. -5°C Tesys D, 2 NO/2 NC contacts
Schneider/Schneider _LC1D65008FE7
Model features introduced
Model parameters are introduced
...
|
|
Schneider _RXM021RB relay protection module socket
RXM021RB Introduction: Schneider Electric relay protection module for a wide range of 6 → 24V ac/dc voltages
Schneider/Schneider _RXM021RB
Model features introduced
Brackets and accessories for RXM series relays
Available in a range of brackets and ...
|
|
Schneider _LC1D40A3F7_ contactor 440 V AC coil 40 A
LC1D40A3F7 Introduction: Schneider Electric Contactor, LC1D Series, 440 V AC Coil, 40 A, 3, min. -5°C Tesys D
Schneider/Schneider _LC1D40A3F7
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LP1K0910CD_ contactors LP1K series
LP1K0910CD Introduction: Schneider Electric contactors, LP1K series, 36 V DC coil, 20 A, 3, minimum operating temperature -25°C TeSys K
Schneider/Schneider_LP1K0910CD
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LC2D40A3E7_ Contactors The minimum operating temperature is -5°C
LC2D40A3E7 Introduction: Schneider Electric Contactors, LC2D Series, 48 V AC Coil, 3, Minimum Operating Temperature -5°C Tesys D
Schneider/Schneider_LC2D40A3E7
Model features introduced
Model parameters are introduced
Seven or six ...
|
|
Schneider _LP4K1201BW3 miniature contactors screw connection
LP4K1201BW3 Introduction: Schneider Electric contactors, LP4K series, 24 V DC coil, 12 A, 3, min. -25°C TeSys K
Schneider/Schneider _LP4K1201BW3
Model features introduced
SchneiderElectric ...
|
|
Schneider_LP1K06013MD3 Contactor 3 NO contacts
LP1K06013MD3 Introduction: Schneider Electric contactors, LP1K series, 230 V DC coils, 6 A, 3 TeSys K, 3 NO contacts
Schneider/Schneider _LP1K06013MD3
Model features introduced
Model parameters are introduced
Seventy-six ...
|
|
Schneider _LC1D50ABBE_ contactor 3-pole DIN rail
LC1D50ABBE Introduction: Schneider Electric contactors, LC1D series, 24 V DC coil, 50 A, 3, min. -25°C Tesys D
Schneider/Schneider _LC1D50ABBE
Model features introduced
TeSysLC1D contactor
Expert...
|
|
Schneider _LC1D50A6FC7_ contactor 3 NO contacts
LC1D50A6FC7 Introduction: Schneider Electric contactors, LC1D series, 3, min. -5°C Tesys D, 3 NO contacts
Schneider/Schneider _LC1D50A6FC7
Model features introduced
Model parameters are introduced
Seven or six ...
|
|
Schneider_RGZE1S48M_ relay socket with screw connector connection
RGZE1S48M Introduction: Schneider Electric relay socket for RXG series relays
Schneider/Schneider _RGZE1S48M
Model features introduced
ZelioRXG interface relays
ZelioRXG interface relays are widely used in PLC interface applications ...
|
|
Schneider _LC1D09G7_ contactor 110 V AC coil 3 NO
LC1D09G7 Introduction: Schneider Electric Contactors, LC1D Series, 110 V AC Coil, 9 A, 3 Tesys D, 3 NO contacts
Schneider/Schneider _LC1D09G7
Model features introduced
3-pole DC controlled contactor
Built-in coil suppression 3 ...
|
|
Schneider AC Contactor LC1-D12M7C AC220V
Introduction: D series AC contactors are rated for impulse withstand voltage of 6-8KV, and the protection level is IP 2X for preventing direct finger contact. It is suitable for controlling various types of motors, capacitors, lights, electric heating and other equipment.
Product parameters
Seven or six ...
|
|
Schneider LC1D18BDC 3-pole contactor
Description: Schneider Electric Contactors, LC1D Series, 24 V DC Coil, 18 A, 3 Locally Made TeSys D, 3 NO Contacts, Category AC3415V AC Switching Voltage3 Poles NO This series of contactors is certified for use in China.
...
|
|
Schneider _LC2D09G7V_ contactor 110 V AC coil
LC2D09G7V Introduction: Schneider Electric Contactors, LC2D Series, 110 V AC Coil, 3, Minimum Operating Temperature -5°C Tesys D
Schneider/Schneider_LC2D09G7V
Model features introduced
Model parameters are introduced
Seven or six ...
|
|
Schneider _LC1K090045M72_ contactor 230 V AC coil 20 A
LC1K090045M72 Introduction: Schneider Electric contactors, LC1K series, 230 V AC coil, 20 A, 4, minimum operating temperature -25°C TeSys K
Schneider/Schneider _LC1K090045M72
Model features introduced
Model Parameters ...
|
|
Schneider _LADC22_ Auxiliary Contact Block Front mounting 4 contacts
LADC22 Introduction: Schneider Electric auxiliary contacts, LADC series, 4 contacts, screw end front mount, 2 NO/2 NO
Schneider/Schneider _LADC22
Model features introduced
Auxiliary contact blocks
In conjunction with a contactor or control relay ...
|
|
Schneider _LP1K090085ED_ Contactors Minimum operating temperature -25°C TeSys K
LP1K090085ED Introduction: Schneider Electric contactor, LP1K series, 48 V DC coil, 20 A, 4, min. -25°C TeSys K
Schneider/Schneider _LP1K090085ED
Model features introduced
Model Parameters ...
|
|
Schneider _LC1E0910E5N_ contactor 690V 3-pole electromagnetic system
LC1E0910E5N Introduction: Schneider Electric Contactors, LC1E Series, 3 TeSys E
Schneider/Schneider _LC1E0910E5N
Model features introduced
Contactor LC1E series
LC1-E series AC contactors are mainly used for applications with 50Hz (or 60Hz...
|
|