Main features
Large capacity up to 1024 segments of program
Set the program arbitrarily within the range of 99 × 10 - 10 × 99 sections.
When setting up to 32 × 32 sections, you can use the full style connection to achieve up to 1024 segments.
Time signal output function/segment signal output function can be selected
You can choose either a time signal output function or a segment signal output function.
・The time signal output function outputs the time according to the set time within the pattern
・The segment signal output function is to set the output in each segment
Grade PIDs and segment PIDs are available
Grade PIDs and segment PIDs can be used separately for each segment.
It is possible to register setpoints in 8 levels (class PIDs) or 8 types of storage groups (segment PIDs).
Equipped with a new algorithm "RSS (Rising · Stabilization · Stabilizer)"
Traceability at the beginning of temperature rise control and suppression of upshoot at the time of stability control are achieved at the same time, improving control stability.
Easy to set up "Front-specific communication + program setting tool"
With a dedicated communication + program setting tool, you can easily set up complex style programs visually.
Main specifications:
Number of input points: 1 point maximum
Input Type: General Purpose Input *Input range refers to the input value range code table (model · price)
1) Temperature·current· low voltage input group
Thermocouples: K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII
Temperature measuring resistor: Pt100, JPt100
DC voltage (low) :D C0 - 10mV, DC-10 - 10mV, DC0 - 100mV, DC-100 - 100mV, DC0 - 1V
DC current input: DC0-20mA, DC4-20mA
2) High voltage input group
DC voltage (high) :D C-1 - 1V, DC0 - 5V, DC1 - 5V, DC0 - 10V
Sampling cycle: 0.1 seconds *Can be changed to 0.05 seconds, 0.25 seconds
Measurement accuracy: ± (0.1% of displayed value + 1 digit) *Varies depending on the input · range
Program control function
1) Memory style: up to 99 styles (variable)
2) Number of segments: up to 1024 segments
*However, the maximum number of segments per style is limited to 99 segments
3) Duration: 0 hours 0 minutes - 500 hours 0 minutes or 0 minutes 0 seconds - 500 minutes and 0 seconds for each period
4) Additional Functions: Fast Forward· Rewind Function, Output Program Function, Copy Function, Label Function, Data Clearing, Display Remaining Time (Segment Remaining Time/Pattern Remaining Time)
Time signal or segment signal
1) Number of output points: 8 points
2) Output: up to 12 points (DO5-12 is optional) Specified by DO allocation
Digital Inputs (DI7-11)
1) Enter the number of points: 5 points
2) Toggle content: RESET, RUN, HOLD, STEP
Style switching, forward/reverse switching
Output(OUT1-2)
1) Relay contact output: 1A contact
2) Voltage pulse output for driving SSR: DC 0/12V
3) Current output: DC 0-20mA, DC 4-20mA
4) Voltage continuous output: DC0-5V, DC1-5V, DC0-10V
5) Open collector output
Digital output (4 points) DO1 - 4: Relay contact output: 1a contact
Event function (4 points): can be arbitrarily assigned to the digital output (DO1-12)
Analog output (1 point): can be arbitrarily assigned to the output (OUT1-3)
Dedicated communication function: RS-485 communication mode
< available specifications >
OUT3
1) Voltage pulse output for driving SSR: DC 0/12V
2) Current output: DC 0-20mA, DC 4-20mA
3) Voltage continuous output: DC0-5V, DC0-10V, DC1-5V, DC0-1V,
4) Open collector output
Digital input (5 points): WAIT is released, and the style is switched
Digital output (8 points) DO5 - 12: open collector output
*The following can be arbitrarily assigned to DO1-12
Time Signal, Event, Heater Disconnection Alarm, Loop Disconnection Alarm, Temperature Input Abnormality, RUN Status, FIX Mode Status, MAN Mode Status,
Ascending state, steady state, HOLD state, waiting state, pattern end signal, AT state, FAIL, HOST/controller communication abnormal,
FBR input is abnormal
Heater disconnection alarm CT input: 2 points max
Opening Feedback Resistance (FBR) Input: 100 – 10kΩ (Standard 135Ω)
Communication function: communication mode: RS-485/RS-422A/RS-232C
Inter-controller communication function: RS-485 communication mode
< general specifications >
Power supply voltage (rated): AC100-240V, AC/DC24V
Allowable ambient temperature: -10 - +55°C
Weight: Approximately 470 g
Safety Standard: UL UL61010-1
cUL CAN/CSA-22.2 NO.61010-1
CE marking: Low Voltage Directive (LVD) EN61010-1
EMC Directive EN61326-1
RCM EN55011
|
More on that
|
Japan RKC Physical and Chemical MA900 Digital Display Thermostat weighs 0.5kg
The MA900 Digital Display Multipoint Controller [ Temperature Controller ] is a product that combines 4 single digital display controllers [ Temperature Controller] with an external dimensions of 96×96×100 (mm). Integrated heating and cooling control, communication function, external contact input function, ...
|
|
Japan Physicochemical RKC RH900AK02-M*GN Thermostat Dual Output Single Alarm 0.3%
RH Series Digital Display Controller [ Temperature Controller ] Plug-in structure with good maintenance performance; At the same time, the product depth has been reduced by 40% compared to the original model (CD series). Yes the new standard temperature controller.
Slim 60mm deep (RD100: 63mm) ...
|
|
Japan RIKA RKC REX-C700 temperature controller 220V
Product Introduction:
Japan Rika RKC model REX-C700 temperature controller.
Brand: RKC
Origin: Japan
Model: REX-C700
Frame: 72*72mm
Appearance: 68*68*100mm
Opening size: 93*4 ...
|
|
The RKC LE100 / LE110 back-pressure level gauges output an 8-point level alarm
Main features
Measure the liquid level with 1 catheter
An inert gas is supplied to a conduit installed in a tank, and the level is measured by the back pressure that occurs in the conduit corresponding to the liquid level.
LE110 is a LE100 type back pressure type level gauge equipped with differential pressure (level gauge pressure and ...
|
|
Japan Rika RKC RB400 Digital Display Controller (Process/Temperature Controller)
Product Introduction:
Japan RIKA RKC digital display controller, model RB400, using ambient temperature 0-50 °C, sampling cycle of 0.25 seconds, accuracy of 0.2% temperature controller, simple change control response (POST fine-tuning function).
Brand: RK ...
|
|
Japan Rika RKC GZ900 Digital Display Controller (Process/Temperature Controller)
Product Introduction:
Japan RIKA RKC GZ900 digital display controller (process/temperature controller) is very effective for process control of high-speed changes such as pressure, flow, and pulse heat that are difficult to control until now through ultra-high-speed feedback control of 100 times per second; Equipped with ...
|
|
Japan RKC Physicochemical Thermostat CH102FK02-M*GN-NN weighs 150kg
Details of the product.
Brand: RKC.
Model: CH102FK02-M*GN-NN.
Measuring range: 0-400, 0-1200°C, etc.
Measurement accuracy: 0.1.
Sampling...
|
|
RKC thermostat RD400DK10-VN-4*4N-NN/AN rated 0.5A
Main features
Four settings can be registered
Four sets of setpoints (SV) can be logged in and switched via digital input (DI).
Rich outputs
*Analog transmission output may not be available depending on the type and type of control.
Abundant output ...
|
|
Japan RIKA RKC JB-150 Portable Temperature Sensor
Product Introduction:
Japan Rika RKC JB-150 Portable temperature sensor, for liquid and semi-solid interiors, the tip of the protective tube (temperature measuring part) is a needle-shaped type that is easy to insert into the measurement object; It is suitable for measuring the temperature of asphalt, etc., and is equipped with a reinforcement specification for protecting pipe joints.
...
|
|
Japan Rika RKC CB100L Limit Controller Sampling cycle: 0.5 seconds
Main features
FM compliant temperature high/low limit controller
Limit the controller's actions
When the temperature controller detects an abnormal increase in temperature, such as a malfunction of the temperature control device, the limiting controller outputs a signal (relay contact output). ...
|
|
RKC Thermostat FB9008N-4*4NN5/A1-F903 Rated current: 0.5A
Main features
Rich combination of event outputs
A wide variety of event output combinations.
Joint operation through communication functions
Communication between controllers is achieved through the joint operation function.
・Automatic heating function with learning function ...
|
|
Japan Rika RKC PZ400 digital program controller 0.05 seconds
Product Details
PA400
The PZ400 is a program controller that can easily set the time for the rise, maintenance and fall of complex target values.
It is easy to operate with the direct setting button
The program capacity is 16 models × 16 segments (linkable) ...
|
|
Japan RIKA RKC thermostat FB400 M8-4*4N8N weighs 0.1kg
Product parameters
Brand Name: RKC/Physical and Chemical
Model: M8-4*4N8N/A1-WD35
Control Type: Temperature
Control Mode: Intelligent Temperature Control Regulator
Measurement object: Heating device
Temperature range :0-1300(°C)
...
|
|
RKC Thermostat Z-TIO-AT-DDDD/A2-F801 JPt100 (3-wire)
Main features
1 small module condensed with 4 temperature controllers
Four CHs can be controlled using one compact module. (Heating and cooling control type is 2 CH)
Temperature control module (Z-TIO) can be connected to up to 16 units (up to 64CH)
A variety of specializations are available.
|
|
RKC thermostat CH402FJ06-M*CC-NN Pt100, JPt100
Main features
Adopt a large LED display
The large LED display can also be seen from a distance
Equipped with a self-tuning function of the judgment control state type
When the control state is judged to be disordered, the PID parameters are automatically adjusted
Loaded with auto-tuning function
...
|
|
Japan RIKA RKC SSN Solid State Relay AC45A for Single Phase
Product Introduction:
Japan RIKA RKC SSN single-phase solid-state relay can be installed in close connection with up to 8 units. The width is only 328 mm, and the ambient temperature characteristics change when mounted in close proximity. 45A size, 41mm wide slim design.
Din rail mounting, screws ...
|
|
Japan RIKA RKC temperature controller MA900 / MA901 mass: about 560g
Introduction: Japan physical and chemical RKC temperature controller MA900 / MA901 mass: about 560g, current output: DC 0-20mA, DC 4-20mA, provide multi-storage area, contact input and output, communication and other rich functions.
peculiarity
With 1 96mm square can achieve a maximum of 8CH...
|
|
RKC thermostat RD700 WJ01-VM-4*1N-NN/AN RS-485 communication
Main features
Four settings can be registered
Four sets of setpoints (SV) can be logged in and switched via digital input (DI).
Rich outputs
Analog transmission outputs may not be available depending on the type and type of control.
Abundant ...
|
|
Japan RIKA RKC GZ series (GZ400/GZ900) digital display controller
Main features
Ultra-high-speed sampling control of 10ms
With ultra-high-speed feedback control of 100 times per second, it is very effective in controlling high-speed changes in pressure, flow rate, pulse heat, etc., which are difficult to control until now.
It is equipped with a front exclusive communication interface
Whole...
|
|
Japan physical and chemical RKC surface temperature probe ST-23 with DP350/700
Product Gallery:
Features:
The RKC surface temperature probe ST-23 uses a maximum temperature of 300°C
Reaction time: 0.8 sec (metal surface) / 5.4 sec (絶縁物surface)
RKC Surface Temperature Probe ...
|
|