IDEC/Izumi SE4D Safety Light Curtain SE9Z-SED-1-T

Create Date: 2024-8-30 12:03:23|Source: IDEC/Izumi

  • Brand:
    IDEC/Izumi
    Origin:
    Japan
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    SE9Z-SED-1-T
    Product Introduction
    The position of the incident light is simple and clear, and the optical axis is easy to confirm the accuracy adjustment function.
Product Description
The position of the incident light is simple and clear, and the optical axis is easy to confirm the accuracy adjustment function.
IDEC/Izumi SE4D Safety Light Curtain SE9Z-SED-1-T
It is possible to construct efficient and economical safety measures without blind spots.

The temporary neutralization feature enables both safety and productivity.

The stowage restart function enables a smooth and safe restart of the production line after a temporary neutralization stop.

It is not affected by the detection width, and achieves a high-speed response of less than 14 ms.

Can be connected in series (up to 3 units or 192 optical axes).

One unit is compatible with PNP transistor output and NPN transistor output.

Safety circuits can be constructed without the need for safety relay modules.

Various blanking functions make it easy to construct a safety system and easy to operate.

It is equipped with a digital fault indicator that shows the fault content at a glance as standard.

Protection class IP65/67 (IEC 60529).

Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only by being professional and careful in every process, every action and every detail of the service can we meet or even exceed customer expectations and make customers satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy.

This article introduces IDEC/Hequan SE4D Safety Light Curtain SE9Z-SED-1-T products, if you are interested in IDEC/Hequan, please also contact our staff, we are looking forward to your call, hope our technology and service can bring you a better experience.

More on that
IDEC/Izumi Safety Relay Module HR6S-AT1C IDEC/Izumi Safety Relay Module HR6S-AT1C

IoT-enabled safety relay modules Equipped with advanced diagnostics and outputs: predictive maintenance 高な診断と出力機能を买載:予知保保保 The switch dial connects a variety of input devices: set the start mode, set the function mode Lock settings and expand outputs At a glance ...

IDEC/Izumi HR1S Safety Relay Module HR1S-AF5130PB IDEC/Izumi HR1S Safety Relay Module HR1S-AF5130PB

It is a dual signal monitoring function such as emergency stop switch and safety switch. Performance index e according to EN ISO 13849-1 and safety category 4. Built-in self-diagnostics to detect faults. Auto-reset or manual reset can be selected. The terminal block is a finger safety protection structure. ...

IDEC/Izumi HS5 series door handle type actuator IDEC/Izumi HS5 series door handle type actuator

Even shaky doors can be locked reliably. The door can be locked/unlocked by turning the door handle. Key features: Smooth insertion and unplugging of shaky doors and actuators with single doors. The door can be locked/unlocked by turning the door handle. Standard locking for operator safety ...

IDEC/Izumi HR2S-332N-T075/T15/T30 Safety Relay Module IDEC/Izumi HR2S-332N-T075/T15/T30 Safety Relay Module

The timed delay output corresponds to safety category 4 Key features: Compatible with PLe according to EN ISO 13849-1, safety category 4. A detachable terminal block with spring-loaded crimp terminals. The connector cover structure prevents contact defects. Width 45mm. ,3NO (i.e. broken) + 3NO (timing ...

IDEC/和泉 安全继电器模块  HR6S-EP1P IDEC/和泉 安全继电器模块 HR6S-EP1P

主要特征 IoT化的安全继电器模块 搭载高级诊断与输出功能:预测性维护 高度な診断と出力機能を搭載:予知保全 切换拨盘连接多种输入设备:设定启动模式、设定功能模式 锁定设定、扩展输出 ...

IDEC/和泉 SE2L型 安全激光扫描器 SE9Z-HS2-BK04L IDEC/和泉 SE2L型 安全激光扫描器 SE9Z-HS2-BK04L

A single unit can protect an area of 270° and 5 m long, so it can be used in a wide range of places, such as large-scale equipment using industrial robots and conveyor lines that continuously transmit long distances. The SE2L is a safety sensor that detects proximity. Simply set the outer area of the 2 protected areas ...

IDEC/和泉 功率继电器 RJ1S-CL-D24 IDEC/和泉 功率继电器 RJ1S-CL-D24

和泉 功率继电器 RJ1S-CL-D24 线圈电压 DC24V 触点数量 1C/O LED指示灯 带 触点材料: 银镍 保护等级: 1P40(封闭型) 接触电阻(初始值)*1: 50mQ以下 吸合时间*2: 15ms以下 释放时 ...

IDEC/Izumi SE2L Safety Laser Scanner SE2L-H05LPC IDEC/Izumi SE2L Safety Laser Scanner SE2L-H05LPC

A single unit can protect an area of 270° and 5 m long, so it can be used in a wide range of places, such as large-scale equipment using industrial robots and conveyor lines that continuously transmit long distances. The SE2L is a safety sensor that detects proximity. Just on the outside of the 2 protected areas that are set ...

IDEC/和泉 安全继电器模块  HR6S-EP1C IDEC/和泉 安全继电器模块 HR6S-EP1C

主要特征 IoT化的安全继电器模块 搭载高级诊断与输出功能:预测性维护 高度な診断と出力機能を搭載:予知保全 切换拨盘连接多种输入设备:设定启动模式、设定功能模式 锁定设定、扩展输出 ...

IDEC/和泉 HR3S型 安全继电器模块 HR3S-301N IDEC/和泉 HR3S型 安全继电器模块 HR3S-301N

具备可简单更换模块的端子部卸装型。 搭载通过双重化安全电路的故障诊断功能。 内置可监视内置继电器动作的LED。 端子台为手指安全保护结构。 35mm宽DIN导轨安装型。 对应EN(欧洲标准)、I ...

IDEC/Izumi SE2L Safety Laser Scanner SE9Z-HS2-BK02 IDEC/Izumi SE2L Safety Laser Scanner SE9Z-HS2-BK02

A single unit can protect an area of 270° and 5 m long, so it can be used in a wide range of places, such as large-scale equipment using industrial robots and conveyor lines that continuously transmit long distances. The SE2L is a safety sensor that detects proximity. Simply set the outer area of the 2 protected areas ...

IDEC/Izumi HR5S Safety Relay Module HR5S-C2S IDEC/Izumi HR5S Safety Relay Module HR5S-C2S

There is no need for redundant safety systems About the introduction of safety systems for low-risk machines. Until now, it has been difficult to achieve safety category 2 control, so low-risk machines are also subject to redundant (safety category 3) control. However, the HR5S safety relay module can be easily implemented to achieve safety ...

IDEC/和泉 HR5S型 安全继电器模块 HR5S-C2D-T050 IDEC/和泉 HR5S型 安全继电器模块 HR5S-C2D-T050

There is no need for redundant safety systems About the introduction of safety systems for low-risk machines. Until now, it has been difficult to achieve safety category 2 control, so low-risk machines are also subject to redundant (safety category 3) control. However, the HR5S safety relay module can be easily implemented to achieve safety ...

IDEC/Izumi SE4D Safety Light Curtain SE9Z-CCB7 IDEC/Izumi SE4D Safety Light Curtain SE9Z-CCB7

The position of the incident light is simple and clear, and the optical axis is easy to confirm the accuracy adjustment function. It is possible to construct efficient and economical safety measures without blind spots. The temporary neutralization feature enables both safety and productivity. The stowage restart function makes the production line smooth and safe after the temporary neutralization stop.

IDEC/和泉 HR1S型 安全继电器模块  HR1S-DME1132P IDEC/和泉 HR1S型 安全继电器模块 HR1S-DME1132P

It is a dual signal monitoring function such as emergency stop switch and safety switch. Performance index e according to EN ISO 13849-1 and safety category 4. Built-in self-diagnostics to detect faults. Auto-reset or manual reset can be selected. The terminal block is a finger safety protection structure. ...

IDEC/Izumi HR5S Safety Relay Module HR5S-C2B IDEC/Izumi HR5S Safety Relay Module HR5S-C2B

There is no need for redundant safety systems About the introduction of safety systems for low-risk machines. Until now, it has been difficult to achieve safety category 2 control, so low-risk machines are also subject to redundant (safety category 3) control. However, the HR5S safety relay module can be easily implemented to achieve safety ...

IDEC/Izumi HR5S Safety Relay Module IDEC/Izumi HR5S Safety Relay Module

Safety Category 2 safety relay modules for use in low-risk machines Key features: There is no need for redundant safety systems About the introduction of safety systems for low-risk machines. Until now, it has been difficult to achieve safety category 2 control, so low-risk machines are also redundant (...

IDEC/Izumi HR3S Safety Relay Module IDEC/Izumi HR3S Safety Relay Module

Compatible with the contact input relay module for the basic type of safety control. Key features: It is equipped with a terminal detachable type that allows for easy module replacement. It is equipped with a fault diagnosis function with a dual safety circuit. Built-in LED that monitors the operation of the built-in relay. Terminal Blocks for Finger Safety ...

IDEC/和泉 SE2L型 安全激光扫描器  SE9Z-HS2-C002 IDEC/和泉 SE2L型 安全激光扫描器 SE9Z-HS2-C002

A single unit can protect an area of 270° and 5 m long, so it can be used in a wide range of places, such as large-scale equipment using industrial robots and conveyor lines that continuously transmit long distances. The SE2L is a safety sensor that detects proximity. Simply set the outer area of the 2 protected areas ...

IDEC/和泉 安全连锁 HS5L微型锁 HS5L-DD44LM-G IDEC/和泉 安全连锁 HS5L微型锁 HS5L-DD44LM-G

4 个触点,双安全电路,1NC+1NC 1NC+1NC 电路,弹簧锁,后解锁按钮 紧凑的机身:35x40x127mm 1400N 锁定强度 适合小负载的镀金触点 头部方向可以旋转 允许 8 个不同的执行器入口 适用标准 ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top