LC1DT25P7 Introduction: Schneider Electric contactors, LC1D series, 230 V AC coil, 25 A, 4, min. -5°C Tesys D
Schneider/Schneider _LC1DT25P7
Model features introduced
SchneiderElectricLC1DTeSysD contactor
SchneiderElectric's TeSysD contactors combine a long mechanical and electrical life and are highly stable contactors. This series is designed to be integrated into control systems and can be used to manufacture motor starters to meet the needs of a variety of applications. TeSysD contactors offer quick and easy setup while complying with international standards.
Features and Benefits:
Built-in auxiliary contacts for increased switching capability Screw Connection: IP20 finger protection terminal blocks with North American and international terminal block markings can be screw-mounted to a panel or mounted to a DIN rail using bidirectional peak limiting diode suppressor protection coils Easy-to-install accessories Flexible control circuitry to suit a variety of applications
What does the use of categories AC1 and AC3 mean for TeSys contactors?
Contactor usage categories define current on and off values based on the type of load and duty cycle conditions to be controlled. AC-1: This category applies to all AC devices with a power factor of at least 0.95. Examples of use: resistive loads, heating, distribution. AC-3: This category applies to squirrel cage motors where a power outage occurs while the motor is running. Examples of use: All squirrel cage motors, elevators, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units.
What accessories does it offer?
Auxiliary contact block with serrated wipe operation is mounted on the front of the dust-proof auxiliary contact block, pneumatic delay block, transient voltage surge suppressor interface module and electronic timer mechanical latch block
Is the TeSysD series a double disconnect pole connector?
Yes, the TeSysD series uses a linear conversion motion to provide polar double disconnection.
Schneider ElectricLC1DT25P7 contactor
The Schneider Electric LC1DT25P7 model is a 4-pole contactor with a 230V AC working coil and an AC-3 current rating of 25A at full load.
Model parameters are introduced
attribute | numeric value | range | TeSysD | series | LC1D | Number of poles | 4 | Coil voltage | 230V AC | Contact current rating | 25A | Contact voltage rating | 690V AC | Normal state configuration | 4. Normally open | Number of auxiliary contacts | 2 | Connector type | screw | length | 85mm | width | 45mm | Maximum operating temperature | +60°C | depth | 90mm | Minimum operating temperature | -5°C |
All suppliers of 76 Technology have been strictly audited to ensure that all sources of goods come from manufacturers or formal agents. Our self-confidence stems from our strict requirements for product quality, adhere to the original genuine products, fake one pay ten, if there is a demand, welcome to consult the delivery date and price, we will select the best quotation for you in many channels, 76 technology multi-brand one-stop procurement, save you time, worry, save money.
The above is the France brand Schneider/Schneider model for the LC1DT25P7 product, the introduction of this product is: Schneider Electric Schneider contactor, LC1D series, 230 V AC coil, 25 A, 4, minimum operating temperature -5°C Tesys D, the purpose of 76 technology is to survive by quality, develop by reputation, and eternity by service, give us a chance and give you a surprise.
|
More on that
|
Schneider _LC1D40A3FE7_ Contactor 3 NO contacts
LC1D40A3FE7 Introduction: Schneider Electric contactors, LC1D series, 3, min. -5°C Tesys D, 3 NO contacts
Schneider/Schneider _LC1D40A3FE7
Model features introduced
Model parameters are introduced
Seven or six ...
|
|
Schneider _LC1K06017F7_ contactor 110 V AC coil 6 A
LC1K06017F7 Introduction: Schneider Electric Contactors, LC1K Series, 110 V AC Coil, 6 A, 3, min. -25°C TeSys K
Schneider/Schneider _LC1K06017F7
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LC2D115Q7_ contactor 400 V cable
LC2D115Q7 Introduction: Schneider Electric Contactors, LC2D Series, 400 V AC Coil, 3, min. -5°C Tesys D
Schneider/Schneider _LC2D115Q7
Model features introduced
Model parameters are introduced
Seven or six ...
|
|
Schneider _LC2K09013B7_ contactor 24 V ac 20 A 3p
LC2K09013B7 Introduction: Schneider Electric contactors, LC2K series, 24 V AC coil, 20 A, 3, minimum operating temperature -25°C TeSys K
Schneider/Schneider _LC2K09013B7
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LP4K1201BW3 miniature contactors screw connection
LP4K1201BW3 Introduction: Schneider Electric contactors, LP4K series, 24 V DC coil, 12 A, 3, min. -25°C TeSys K
Schneider/Schneider _LP4K1201BW3
Model features introduced
SchneiderElectric ...
|
|
Schneider _LC2D38P7V_ contactors LC2D series 230 V
LC2D38P7V Introduction: Schneider Electric Contactors, LC2D Series, 230 V AC Coil, 3, Minimum Operating Temperature -5°C Tesys D
Schneider/Schneider _LC2D38P7V
Model features introduced
Model parameters are introduced
Seven or six ...
|
|
Schneider _LC1D09G7_ contactor 110 V AC coil 3 NO
LC1D09G7 Introduction: Schneider Electric Contactors, LC1D Series, 110 V AC Coil, 9 A, 3 Tesys D, 3 NO contacts
Schneider/Schneider _LC1D09G7
Model features introduced
3-pole DC controlled contactor
Built-in coil suppression 3 ...
|
|
Schneider _LC1D40A6D7_ Contactor 3 NO contacts
LC1D40A6D7 Introduction: Schneider Electric Contactors, LC1D Series, 3, min. -5°C Tesys D, 3 NO contacts
Schneider/Schneider_LC1D40A6D7
Model features introduced
Model parameters are introduced
76 Technology ...
|
|
Schneider/Schneider _LC1K06015V7_ Contactor 3 NO contact 400 V AC
LC1K06015V7 Introduction: Schneider Electric contactors, LC1K series, 400 V AC coils, 6 A, 3 TeSys K, 3 NO contacts
Schneider/Schneider_LC1K06015V7
Model features introduced
Model parameters are introduced
Seven or six ...
|
|
Schneider _LP2K09015JD3_ contactor 12 V 20 A
LP2K09015JD3 Introduction: Schneider Electric contactor, LP2K series, 12 V DC coil, 20 A, 3, minimum operating temperature -25°C TeSys K
Schneider/Schneider _LP2K09015JD3
Model features introduced
Model Parameters ...
|
|
Schneider _LC1D17000F7C_ Contactor 3 NO Contact 3P
LC1D17000F7C Introduction: Schneider Electric contactor, LC1D series, 110 V AC coil, 170 A, 3 domestic TeSys D, 3 NO contact 3P
Schneider/Schneider_LC1D17000F7C
Model features introduced
3-pole AC and DC ...
|
|
Schneider _LC1F265ED_ Contactor 3 NO contacts
LC1F265ED Introduction: Schneider Electric Contactors, LC1F Series, 3, min. -5°C TeSys F, 3 NO contacts
Schneider/Schneider _LC1F265ED
Model features introduced
Model parameters are introduced
76 Science and Technology Institute ...
|
|
Schneider _LC1D50A3FE7_ contactor 440 V AC coil, 50 A
LC1D50A3FE7 Introduction: Schneider Electric Contactors, LC1D Series, 440 V AC Coil, 50 A, 3, min. -5°C Tesys D
Schneider/Schneider _LC1D50A3FE7
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LC1D40A6L7_ contactor 440 V AC 40 A
LC1D40A6L7 Introduction: Schneider Electric contactors, LC1D series, 440 V AC coil, 40 A, 3, min. -5°C Tesys D
Schneider/Schneider_LC1D40A6L7
Model features introduced
Model parameters are introduced
...
|
|
Schneider _LC1D25C7_ Contactor 3 NO contact 36 V
LC1D25C7 Introduction: Schneider Electric Contactors, LC1D Series, 36 V AC Coil, 25 A, 3 Tesys D, 3 NO Contacts
Schneider/Schneider_LC1D25C7
Model features introduced
3-pole contactor, AC controlled, rated power: 1 ...
|
|
Schneider _LC2DT32Q7_ contactors 400 V minimum operating temperature -5°C
LC2DT32Q7 Introduction: Schneider Electric Contactors, LC2D Series, 400 V AC Coil, 4, min. -5°C Tesys D
Schneider/Schneider _LC2DT32Q7
Model features introduced
Model parameters are introduced
Seven or six ...
|
|
Schneider _LA4SKE1U_ contactor coil suppressor module
LA4SKE1U Introduction: Schneider Electric contactors, LA4S series, 230 V AC coils, minimum operating temperature -20°C TeSys SK
Schneider/Schneider_LA4SKE1U
Model features introduced
Coil suppressor module
For high RF interference ...
|
|
Schneider _LC1DT20CD_ Contactor 4 NO contact -5°C
LC1DT20CD Introduction: Schneider Electric contactors, LC1D series, 4, min. -5°C Tesys D, 4 NO contacts
Schneider/Schneider _LC1DT20CD
Model features introduced
Model parameters are introduced
76 Science and Technology Institute ...
|
|
Schneider _LC1D323FD_ Contactor 3 NO 18.5kW 32 A
LC1D323FD Introduction: Schneider Electric contactor, LC1D series, 110 V DC coil, 32 A, 3, min. -5°C Tesys D
Schneider/Schneider _LC1D323FD
Model features introduced
Model parameters are introduced
...
|
|
Schneider_LC1D188BD 4-pole contactor, DC controlled
LC1D188BD Introduction: Schneider Electric Contactors, LC1D Series, 24 V DC Coil, 32 A, 4 Tesys D, 2 NO/2 NC contacts
Schneider/Schneider _LC1D188BD
Model features introduced
4-pole contactor, DC controlled
Envoy...
|
|