KEYENCE/KEYENCE Touchscreen Paperless Recorder TR-W Series
Introduction: KEYENCE/KEYENCE Touchscreen Paperless Recorder TR-W Series simply touches the screen and slides your finger to view past waveforms. It feels like you're flipping through a chart paper, and it's intuitive to operate (slide the scrolling screen). In addition, you can also drag and drop the screen with your finger to automatically reshape the waveform.
|
|
KEYENCE/KEYENCE Fiber Optic Unit Permeable FU-35FA
Fiber Optic Unit Reflective FU-35FA
Size: M3
Detection configuration: Coaxial
Fiber Optic Device Length: 1m Free Cut
Diameter of the fibre optic unit: ø1.3×2
Shape: Straight
Minimum bending radius: R25 mm
Minimum detection object: ø0.005 mm gold wire*2
Ring...
|
|
KEYENCE/KEYENCE Programmable Controller KV-8000 Series Insulation voltage 50 ohms
Introduction: KEYENCE/KEYENCE Programmable Controller KV-8000 Series enables seamless connectivity from FA equipment to PLC. Program-free PLC communication, excellent "responsiveness" expands new applications. KV-X MOTION strives to build a system that meets all needs
Features:
...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Reflective FU-10
Type: Variable light spot
Distance to center: 10 to 30 mm
Fiber optic device length: 2m free cut
Diameter of the fibre optic unit: ø1.3×2
Environmental resistance: Ambient temperature: -40 to +70 °C
Weight: approx. 5 g
This article introduces the KEYENCE/KEYENCE Fiber Optic Single...
|
|
KEYENCE/KEYENCE Fiber Optic Unit Limited Reflective Type FU-38K
Fiber Optic Unit Limited Reflective Type FU-38K
Heat-resistant temperature: 250°C*2
Length of fiber optic installation: 1m cannot be cut
Minimum bending radius: R25 mm
Environmental Resistance Ambient temperature: -40 to +250 °C
Weight: approx. 45 g
This article introduces the KEYENCE/KEYENCE Light ...
|
|
KEYENCE/KEYENCE Amplifier Neutral Expansion Unit LV-N10
Amplifier neutral expansion unit LV-N10
Control the output
NPN open collector 30 V, residual voltage 1 V or less (output current: 10 mA or less) / 2 V or less (output current: 10 to 100 mA)
(Independent) 1 maximum output: 100 mA or less ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-13
Fiber Optic Unit Regressive Reflective FU-13
Fiber optic device length: 2m free cut
Diameter of the fibre optic unit: ø1.0×2
Minimum bending radius: R2 mm without bending
Environmental Resistance Ambient temperature: -40 to +50 °C
Weight: approx. 8 g
This article introduces the KEYENCE/KE...
|
|
KEYENCE/KEYENCE sensor head LJ-X8200
KEYENCE Sensor Head LJ-X8200 Enclosure Rating: IP67(IEC60529)*9
Ambient light: Incandescent lamp: 10000 lux or less*10
Ambient temperature: 0 to +45°C*11
Relative humidity: 85%RH or less (no condensation)
Shock resistance: 10 to 57 Hz double amplitude 1. ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-24X
Fiber Optic Unit Reflective FU-24X
Size: M3
Detection configuration: Coaxial
Fiber optic device length: 50cm cannot be cut
Shape: Straight
Minimum bending radius: R10 mm
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Ambient temperature: -40 ...
|
|
KEYENCE 3D Development Edition Controller LJ-X8000ASO(55208)
Control Inputs: Start Batch Measurement (MEASURE_START), Stop Batch Measurement (MEASURE_STOP)
Control outputs: Trigger Ready (READY), System Error (ERROR), Solid State Relay*4:
Input/output synchronization: ...
|
|
KEYENCE/KEYENCE Amplifier Cable Main Unit PNP LV-N11P
KEYENCE Amplifier Cable Main Unit PNP LV-N11P
Output: PNP
Supply voltage: 24 VDC (operating voltage 10-30 VDC (including ripple)), ripple (P-P) 10 % or less, Class 2 or LPS*4*5
Power consumption: Normal: 950 mW or less (3 ...
|
|
KEYENCE/KEYENCE Input Unit CA-E200LJSO(55211)
LJ-X/LJ-V Input Unit CA-E200LJSO(55211)
This article introduces the KEYENCE/KEYENCE input unit CA-E200LJSO(55211) products, if you are interested in KEYENCE/KEYENCE products, please also contact our customer service, we are looking forward to your call, hope I ...
|
|
KEYENCE/KEYENCE AC Servo SV Series Rated load 30VDC
Introduction: KEYENCE/KEYENCE AC Servo SV Series This is a lineup of mid-inertia · medium-capacity motors that shorten production intervals, achieve high-speed, high-precision control, and achieve high-speed· high-torque.
Product parameters
This article introduces the KEYENCE/KEYENCE AC Servo System SV...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-16Z
Fiber Optic Unit Permeable FU-16Z
Optical axis diameter (standard object to be detected): ø2.5 mm
The direction in which the light is emitted: Sideways
Opening angle: Approximately 6°
Fiber optic device length: 2m free cut
Diameter of fiber optic unit: ø1.0
Minimum bending radius: R2 mm without bending
Least...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-20
Fiber Optic Unit Reflective FU-20
Type: Small spot type
Distance to center: 5 mm
Fiber optic device length: 50cm cannot be cut
Minimum bending radius: R25 mm
Environmental Resistance Ambient temperature: -40 to +70 °C
Weight: approx. 2 g
This article introduces the KEYENCE/KE...
|
|
KEYENCE/KEYENCE Ultra-High Speed Profile Measuring Instrument LJ-V7000 Series
The industry's ultra-fast speed of 64,000 contours/second, can measure materials with different reflective intensities at the same time, high speed, high precision, high stability.
This article introduces the KEYENCE/KEYENCE Ultra-High Speed Profile Measuring Instrument LJ-V7000 series products, if you are interested in KEYENCE/KEYENCE products ...
|
|
KEYENCE/KEYENCE Programmable Controller KV Nano Series Rated load 30VDC
Introduction: KEYENCE/KEYENCE programmable controller KV Nano series has a built-in recording function. The dedicated wizard allows you to set the soft components you want to record and the timing of the trigger, and you can start recording by simply writing a ladder diagram of the start and stop of recording. It only takes 2 steps to set it up.
Product Features ...
|
|
KEYENCE/KEYENCE sensor head LJ-X8060
Sensor head LJ-X8060 reference distance: 64 mm
Enclosure Rating: IP67(IEC60529)*9
Ambient light: Incandescent lamp: 10000 lux or less*10
Ambient temperature: 0 to +45°C*11
Relative humidity: 85%RH or less (no condensation)
Seismic resistance: 10 to ...
|
|
KEYENCE/KEYENCE Programmable Controller KV-8000 CPU Unit
CPU unit KV-8000
Supply voltage
When using the system configuration of the KV-5000/3000 series expansion units: 24 VDC (±10%)
When only KV-8000/7000 series expansion units are built: 24 VDC (-15%+20%)
Environment: No large amount of dust, ...
|
|
KEYENCE/KEYENCE Fiber Optic Unit FU-23X
KEYENCE/KEYENCE Fiber Optic Unit FU-23X
Size: ø3 mm
Fiber optic device length: 50cm cannot be cut
Minimum bending radius: R25 mm
Minimum detection object: ø0.005 mm gold wire*2
Environmental Resistance Ambient temperature: -40 to +70 °C