1. The capacitance is generally indicated by "C" plus a number in the circuit (e.g., C25 indicates the capacitance numbered 25).
A capacitor is a component consisting of two metal films close to each other and separated by an insulating material in the center. The characteristic of the capacitor is mainly to communicate through the DC block. The size of the capacitance is to indicate the size of the energy that can be stored, and the blocking effect of the capacitor on the communication signal is called capacitive reactance, which is related to the frequency and capacitance of the communication signal.
Capacitive reactance XC=1/2πf c (f indicates the frequency of the communication signal, C indicates the capacitance capacity)
2. Capacitance identification method
The identification method of capacitance is basically the same as that of resistor, and there are three types: direct standard method, color mark method and number mark method. The basic unit of capacitance is indicated by farad (F), and other units are: millimethod (mF), micromethod (uF), nanomethod (nF), picomethod (pF).
Wherein: 1 farad = 103 millifa = 106 microfarat = 109 nanofa = 1012 picofara
Capacitors with large capacitances have capacitance values that are indicated directly on the capacitor, e.g. 10 uF/16V
A capacitor with a small capacitance has a capacitance value indicated by a letter on the capacitance or a number indicating 6
Letter indication method: 1m = 1000 uF 1P2 = 1.2PF 1n = 1000PF
Numerical indication: Generally, three digits are used to indicate the size of the capacity, the first two digits indicate significant figures, and the third digit is the magnification.
For example, 102 indicates 10×102PF=1000PF 224 indicates 22×104PF=0.22 uF
3. Capacitance capacity error table
Symbol F G J K L M
Error ±1% ±2% ±5% ±10% ±15% ±20%
For example, if the capacitance of a ceramic tile is 104J, the capacitance is 0. 1 uF, error of ±5%.
4. Characteristics of the problem
In the actual repair, the fault of the capacitor is mainly manifested as: (1) The open circuit problem caused by pin corrosion.
(2) The problem of open circuit of desoldering and virtual soldering. (3) Leakage causes small volume or open circuit problems.
(4) Leakage, serious leakage and breakdown problems.
|
More on that
|
Common problems in the use of inverter - Sunland inverter
1. Please explain the maintenance function of the inverter?
(1) After detecting the abnormal situation, the correction action will be carried out automatically, such as overcurrent loss rate prevention, regeneration overvoltage stall prevention.
(2) After detecting the abnormality, the PWM control signal of the power semiconductor device is closed, so that the motor can park automatically. As...
|
|
Precautions for inverter wiring - hope Senlan
1. The inverter itself has strong electromagnetic disturbance, which will disturb the operation of some equipment, so we can add a cable sleeve to the output cable of the inverter.
2. The control line in the inverter or control cabinet is spaced at least 100mm, and the power cable is at least 100mm.
3. In the purchase of inverter ...
|
|
Sunland - inverter operation process and factory value restoration
The general operation process is as follows:
Enter the program through the operation panel and set the parameters, and set the relevant parameter groups such as the start-stop method, operation and control form according to the requirements of the industrial control. After confirming that the wiring is correct, the no-load power on test run and ...
|
|
Precautions for the use of industrial touch screen all-in-one machine
1. The contact screen all-in-one machine adopts the new contact identification technology, and the user only needs to touch it lightly on the contact screen without passing the pressure sensing to complete the operation. Care must be taken not to use too much force or sharps to scratch the surface of the contact screen.
...
|
|
Hope Sunland inverter EMC rules
When various factory equipment uses frequency conversion speed regulation, harmonic disturbances will be generated on the power supply side and motor side of the inverter (VFD), which will cause electromagnetic disturbance to the power supply network and other electrical equipment near the VFD. In addition, in order to ensure the long-term reliable operation of the VFD, the wiring of the VFD is very important.
...
|
|
Characteristics of two-phase electric fan inverter - Sunland inverter
The digital signal processor is selected, and the work efficiency is higher
A good quality two-phase electric fan inverter uses a digital signal processor, which can make the work efficiency higher, that is, it may take 3 hours to complete the work, but now it only takes 2 hours to be able to...
|
|
The reason for VFD trip protection - Senlan
In general, there is a problem with the maintenance trip of the VFD. If you look at the faulty code, you can see what kind of fault is causing it.
1. The selection talent of VFD may be too small; Generally, when selecting VFD, it should be about 20% larger than the rated power of the motor, so that when the motor reaches full load...
|
|
The reason why the inverter damaged the motor - Senlan
The presentation of inverters has brought a revolution to industrial automation control and motor energy saving. Industrial production is simply inseparable from the inverter, even in the daily livelihood, elevators, inverter air conditioning has become a part of the insistence, inverter from the beginning into all corners of production, subsistence. However...
|
|
The cause of the leakage problem of Sunland inverter
1. The cause of inverter leakage
According to the inverter to control the operation of the motor, the three-phase electricity is supplied to the inverter bridge (IGBT) through the filter capacitor through the rectification, and then the operation of the motor is controlled by the three-phase electricity with adjustable output frequency and voltage of the inverter.
We all know that the three-phase stator winding of the motor ...
|
|
It is hoped that Senlan will become the most powerful shore power solution provider in China
Founded in 1998, Hope Lansen is a national high-tech enterprise in the fields of energy conservation and environmental protection, new energy, transmission control and intelligent equipment in China, integrating R&D, manufacturing, system integration and customer service. Its products cover high and low voltage frequency conversion control systems, automated production lines and robot transmission systems.
|
|
Sunland inverters are designed for environmental requirements
1. The ambient temperature ---- is generally "-10-+40°C"; Derating between 40 and 50°C, the additional output current must be reduced by 1% for every 1°C increase. If the ambient temperature is too high and the temperature changes greatly, the insulation of the inverter will be greatly reduced, which will affect the life of the inverter.
...
|
|
Fault signal processing method of frequency converter
(1) Check whether the motor is hot.
If the temperature rise of the motor is not high, you should first check whether the size of the load, the acceleration and deceleration time, and the running cycle time are reasonable, and correct the V/F characteristics, and check whether the electronic thermal protection function of the inverter is preset reasonably, such as the inverter.
|
|
Precautions for using inverter - Sunland inverter
A frequency converter (VFD) is an electrical energy control device that converts a power supply to another frequency by using the on-off effect of power semiconductor equipment. It can realize the soft start, frequency conversion speed regulation, improved operation accuracy, power factor, overcurrent/overvoltage/overload protection of AC asynchronous motor, etc.
|
|
Inverter-related knowledge - Senlan inverter
1. What does open-loop mean in the use of inverters?
The speed detector (PG) is installed on the motor equipment in operation, and the speed response of the actual speed is sent to the control equipment, which is called "closed loop", and the speed detector that does not use PG is called "open loop". Most general-purpose drives are open-loop ...
|
|
Inverter super password summary
1. Delta's super password-B series: 57522; - H-series: 33582; S1 series inverter universal password: 575222.
Second, Huifeng inverter (that is, now Ou Rui inverter), the general super password of its products is: 18881500-G 1500-P 1000- ...
|
|
The manufacturing standard of Sunland inverter cabinet
Planning specifications: The planning of inverter cabinets should conform to relevant national norms and industry norms, such as GB/T15576-2018 "Low-voltage Distribution Cabinet", GB7251.1-2017 "Low-voltage Complete Switchgear and Control Equipment", etc.
Material specifications: The materials of the control cabinet should conform to the relevant codes and regulations.
|
|
Inverter control motor speed method - Senlan
1. Why can the rotation speed of the motor be changed freely?
The unit of motor rotation speed: r/min the number of rotations per minute, can also be expressed as rpm.
Example: 2-pole motor 50Hz3000 [r/min]
4-pole motor 50Hz1500[r/min]
Conclusion: The rotation of the motor ...
|
|
The overload capacity of the dry-type transformer - Sunland inverter
Dry-type transformer is a kind of power equipment, and under normal circumstances, dry-type transformer also requires a certain amount of overload, that is, the workload beyond its working ability. So what about the overload of dry-type transformers and how to influence them?
...
|
|
The remote control of the inverter meets the function - Sunland inverter
In general, the long-distance operation of the frequency converter requires the following functions:
1) Long-distance setting, if the parameters only need to be set for the first time, and do not need to be adjusted during operation, then long-distance setting is not required.
2) Long-distance start-stop, long-distance start or stop inverter, and ...
|
|
The method of selecting the appropriate peripheral equipment for the inverter - Senland
When we have selected a suitable Variable-frequency Drive (VFD), we also need to consider whether we need to equip other peripheral equipment according to the actual situation of the site. The peripheral equipment selected by VFD mainly includes circuit breakers, reactors, contactors, braking resistors, etc.
...
|
|