SICK/Sick cylindrical photoelectric sensor GRSE18S-P1121V cable 4-pin

Create Date: 2024-8-30 12:03:23|Source: SICK/Sick

  • Brand:
    SICK/Sick
    Origin:
    Germany
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    GRSE18S-P1121V
    Product Introduction
    Housing length 55.9 mm
    Available thread length 31.7 mm
    Screw diameter (housing) M18 x 1
    Optical axis axial
Product Description
Introduction: SICK photoelectric sensors are divided into mini, small, compact, optical fiber and cylindrical according to the size and installation method; From the working mode, it is divided into diffuse reflection, mirror reflection and through-beam type. It is usually used for the localization and detection of moving objects. The mini type is suitable for occasions where the installation space is limited, and the detection distance of most mini ordinary LED light sources is less than 1 meter, the detection distance of the mirror reflection type is less than 10 meters, and the through-beam type is about 20 meters, and the detection distance of the laser light source will be higher than this range. The detection range of the small and compact version will be further extended and the maximum through-beam distance of up to 350 meters is now available.
                                   SICK/SICK GRSE18S-P1121V
Product parameters

Sensor Principle / Detection Principle Thru-beam photoelectric sensor

Dimensions (W x H x D) 18 mm x 18 mm x 55.9 mm

Housing shape (beam outlet) cylindrical

Housing length 55.9 mm

Available thread length 31.7 mm

Screw diameter (housing) M18 x 1

Optical axis axial

Maximum switching distance 0 m ... 15 m

Sensing distance 0 m ... 10 m

Type of light source Infrared

Light source LED 1)

Spot size (distance) Ø 420 mm (10 m)

Shaft length 850 nm

Settings None

Special Applications Hygienic and humid environments

Supply voltage 10 V DC ... 30 V DC 1)

Residual Ripple ± 5 Vss 2)

Current consumption 30 mA

Switching output PNP

Switching function Compensation amount

Switch Type: Light/Dark Toggle 3)

Signal voltage PNP high/low approx. UV - (≤ 3 V)/ approx. 0 V

Output current Imax.        100 mA 4)

Response time < 500 μs 5)

Switching frequency 1,000 Hz 6)

Connection Type Cable 4-pin, 2 m 7)

Wire Material: PVC

Conductor cross-section 0.14 mm²

Conductor diameter 4.8 mm

Protection circuits

  A 8)

  B 9)

  D 10)

Protection class III

Weight 190 g

Housing material: Stainless steel, V4A (1.4404,316L) stainless steel

Materials, Optics Plastics, PMMA

Maximum tightening torque 90 Nm

Enclosure rating

  IP67

  IP68 11)

  IP69K 12)

Scope of delivery Fixing nuts (4 x)

Electromagnetic compatibility EN 60947-5-2

Test the input transmitter off via "Test" 0 V

Operating ambient temperature –25 °C ... +55 °C 13)

Storage ambient temperature –30 °C ... +75 °C

This article introduces SICK/Sick photoelectric sensor products, if you are interested in RKC, please also contact our staff, we look forward to your call, hope our technology and service can bring you a better experience.

The company respects the enterprise spirit of "practicality, hard work and responsibility", and creates a good corporate environment with integrity, win-win, and business philosophy, and takes a new management model, perfect technology, thoughtful service, and excellent quality as the foundation for survival. We always adhere to: customer first, serve customers attentively, and insist on impressing customers with their own services. Always adhering to the business philosophy of "integrity, win-win", relying on excellent prices, excellent quality, fast delivery and pre-sales consultation and after-sales service to win the trust of our customers.

More on that
SICK/Sick miniature photoelectric sensor WL9-3P3432 weighs 80g SICK/Sick miniature photoelectric sensor WL9-3P3432 weighs 80g

Introduction: SICK photoelectric sensors are divided into mini, small, compact, optical fiber and cylindrical according to the size and installation method; From the working mode, it is divided into diffuse reflection, mirror reflection and through-beam type. It is usually used for the localization and detection of moving objects. The miniature type is suitable for installing empty ...

The SICK/Sick cylindrical photoelectric sensor GRSE18S-P133Y consumes 30 mA The SICK/Sick cylindrical photoelectric sensor GRSE18S-P133Y consumes 30 mA

Introduction: SICK photoelectric sensors are divided into mini, small, compact, optical fiber and cylindrical according to the size and installation method; From the working mode, it is divided into diffuse reflection, mirror reflection and through-beam type. It is usually used for the localization and detection of moving objects. The miniature type is suitable for installing empty ...

SICK GTB6-N1211 sensor Switching frequency: 1,000 Hz 6) SICK GTB6-N1211 sensor Switching frequency: 1,000 Hz 6)

Parametric technology Working principle: Diffuse photoelectric sensor Working details: Background suppression Maximum switching distance: 5 mm ... 250 mm 1) Sensing distance: 35 mm ... 140 mm Polarization Filter: No Emit beams ...

Compact photoelectric sensor GTB2F-F511 Background suppression, diffuse reflection Compact photoelectric sensor GTB2F-F511 Background suppression, diffuse reflection

Product introduction: Photoelectric sensor is high-tech automation needs intelligent detection. Smart Sensors generate and receive data and information that goes far beyond traditional switching signals or measured process data. As a result, sensors offer significant efficiency gains, greater flexibility and better safety planning in advance.

SICK/SICK Miniature Photoelectric Sensor WL4SL-3F2232 Single teach-in button SICK/SICK Miniature Photoelectric Sensor WL4SL-3F2232 Single teach-in button

Product introduction: Photoelectric sensor is high-tech automation needs intelligent detection. Smart Sensors generate and receive data and information that goes far beyond traditional switching signals or measured process data. As a result, sensors offer significant efficiency gains, greater flexibility and better safety planning in advance.

The SICK/SICK cylindrical photoelectric sensor GRTB18S-F1417 has a sensing distance of 20 to 150 mm The SICK/SICK cylindrical photoelectric sensor GRTB18S-F1417 has a sensing distance of 20 to 150 mm

Product introduction: Photoelectric sensor is high-tech automation needs intelligent detection. Smart Sensors generate and receive data and information that goes far beyond traditional switching signals or measured process data. As a result, sensors offer significant efficiency gains, greater flexibility and better safety planning in advance.

SICK/Sick cylindrical photoelectric sensor GRTB18S-P2417 100 mm SICK/Sick cylindrical photoelectric sensor GRTB18S-P2417 100 mm

Product introduction: Photoelectric sensor is high-tech automation needs intelligent detection. Smart Sensors generate and receive data and information that goes far beyond traditional switching signals or measured process data. As a result, sensors offer significant efficiency gains, greater flexibility and better safety planning in advance.

The GRL18S-P235W cylindrical photoelectric sensor from SICK has a shaft length of 650 nm The GRL18S-P235W cylindrical photoelectric sensor from SICK has a shaft length of 650 nm

Introduction: SICK photoelectric sensors are divided into mini, small, compact, optical fiber and cylindrical according to the size and installation method; From the working mode, it is divided into diffuse reflection, mirror reflection and through-beam type. It is usually used for the localization and detection of moving objects. The miniature type is suitable for installing empty ...

SICK IME12-04BPSZC0S inductive proximity switch 2000 Hz SICK IME12-04BPSZC0S inductive proximity switch 2000 Hz

Product Introduction Design Construction: Metric design Housing Shape: Standard Thread size: M12 x 1 Diameter: ∅12 mm Sensing distance S: 4 mm Safe switching distance S: 3.24 mm Mounted on metal: flush Switch...

SICK/Sick cylindrical photoelectric sensor GRTE18S-P1342 M18 x 1 SICK/Sick cylindrical photoelectric sensor GRTE18S-P1342 M18 x 1

Introduction: SICK photoelectric sensors are divided into mini, small, compact, optical fiber and cylindrical according to the size and installation method; From the working mode, it is divided into diffuse reflection, mirror reflection and through-beam type. It is usually used for the localization and detection of moving objects. The miniature type is suitable for installing empty ...

SICK miniature photoelectric sensor WTB4S-3F2132V SICK miniature photoelectric sensor WTB4S-3F2132V

Product introduction: Photoelectric sensor is high-tech automation needs intelligent detection. Smart Sensors generate and receive data and information that goes far beyond traditional switching signals or measured process data. As a result, sensors offer significant efficiency gains, greater flexibility and better safety planning in advance.

SICK/Sick miniature photoelectric sensor WTB4-3F1361 3-core 2 m SICK/Sick miniature photoelectric sensor WTB4-3F1361 3-core 2 m

Product introduction: Photoelectric sensor is high-tech automation needs intelligent detection. Smart Sensors generate and receive data and information that goes far beyond traditional switching signals or measured process data. As a result, sensors offer significant efficiency gains, greater flexibility and better safety planning in advance.

The SICK/SICK miniature photoelectric sensor WTV2S-2P3120 has a shaft length of 640 nm The SICK/SICK miniature photoelectric sensor WTV2S-2P3120 has a shaft length of 640 nm

Introduction: SICK photoelectric sensors are divided into mini, small, compact, optical fiber and cylindrical according to the size and installation method; From the working mode, it is divided into diffuse reflection, mirror reflection and through-beam type. It is usually used for the localization and detection of moving objects. The miniature type is suitable for installing empty ...

The WL34-V230 photoelectric sensor from SICK has a current consumption of 50 mA The WL34-V230 photoelectric sensor from SICK has a current consumption of 50 mA

Product Introduction Product name: SICK Product Type: Retro-reflective photoelectric sensors Model WL34-V230   Working principle Retroreflective photoelectric sensor Details of the working principle of the double lens Dimensions (W x H x D) 27 ...

SICK sensor WT100L-F1141 Switching output: PNP SICK sensor WT100L-F1141 Switching output: PNP

Product Introduction Product name: SICK The product range W100 Laser Model WT100L-F1141   Working principle Diffuse photoelectric sensor Working principle details Energy type Dimensions (W x H x D) 11 mm x 31 m ...

SICK sensor OD2-P50W10I0 DC 12 V ... 24 V SICK sensor OD2-P50W10I0 DC 12 V ... 24 V

Product Introduction Product name: SICK Product Type: Displacement measurement sensor The product model is OD2-P50W10I0   Mechanical/electronic parameters Supply voltage Uv DC 12 V ... 24 V Power consumption ≤ 2.88 W 1) Warm-up time ≤ ...

Sick servo feedback encoder STS hollow shaft inner diameter: 84 mm Sick servo feedback encoder STS hollow shaft inner diameter: 84 mm

Description: HIPERFACE® STS servo feedback encoder hollow shaft inner diameter: 84 mm, usable storage space: 128 bytes, mechanical interface: through-hole hollow shaft.   parameter Communication interface: HIPERFACE® Sine/Cosine period per revolution: 158 ...

SICK 4Dpro connection technology CDB620-001 9-pin D-Sub plug (internal) SICK 4Dpro connection technology CDB620-001 9-pin D-Sub plug (internal)

Product Introduction Product name: SICK Product Type: 4Dpro connection technology Product family Connection Device Basic / CDB620 The product model is CDB620-001   Brief description Small connection module for sensors, 4 PG ...

SICK/SICK cylindrical photoelectric sensor GRTE18-P2462 <1,000 μs4 SICK/SICK cylindrical photoelectric sensor GRTE18-P2462 <1,000 μs4

Introduction: SICK photoelectric sensors are divided into mini, small, compact, optical fiber and cylindrical according to the size and installation method; From the working mode, it is divided into diffuse reflection, mirror reflection and through-beam type. It is usually used for the localization and detection of moving objects. The miniature type is suitable for installing empty ...

SICK/Sick cylindrical photoelectric sensor GRTB18S-P1317 potentiometer 270° SICK/Sick cylindrical photoelectric sensor GRTB18S-P1317 potentiometer 270°

Product introduction: Photoelectric sensor is high-tech automation needs intelligent detection. Smart Sensors generate and receive data and information that goes far beyond traditional switching signals or measured process data. As a result, sensors offer significant efficiency gains, greater flexibility and better safety planning in advance.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top