Schneider ATV600 - ATV630U07M3 Introduction:
Width: 144 mm, height: 350 mm, depth: 203 mm Product weight: 4.3 kg, Analog input quantity: 3 Discrete input quantity: 8 Analog output quantity: 2 Relay output quantity: 3 IP protection class: IP21 Storage ambient temperature: -40... 70 °C
Key messagesProduct range | ATV Yucheng series ATV600
| | Product type | Frequency converters
| | Fields of application | Process applications
| | Short name of the product | ATV630
| | variable | Standard version
| | Product features | Synchronous motors
Asynchronous motors
| | Installation type | wall-mounted
| | EMC filters | No EMC filters
| | IP protection rating | IP21 complies with IEC 61800-5-1
IP21 complies with IEC 60529
| | Ingress protection | UL Type 1 UL 508C
| | Cooling method | Forced ventilation
| | Power supply frequency | 50...60 Hz - 5...5 %
| | The number of phases of the network | 3 phases
| | Rated supply voltage [us] | 200...240 V - 15...10 %
| | Motor power (kW) | 0.75 kW standard load
0.37 kW heavy load
| | Motor power | 1 hp standard load
0.5 hp heavy load
| | Line current | 3 A 200 V standard load
2.6 A 240 V standard load
1.7 A 200 V overload
1.5 A 240 V overload
| | Expected line Isc | 50 kA
| | Apparent power | 1.1 kVA 240 V standard load
0.6 kVA 240 V heavy load
| | Continuous output current | 4.6 A 4 kHz standard load
3.3 A 4 kHz overload
| | Maximum transient current | 5.1 A 60 sec standard load
5 A 60 sec reload
| | Asynchronous motor control profile | Optimized torque mode
Standard variable torque
Standard constant torque
| | Synchronous motor control configuration mode | Synchronous reluctance motor
Permanent magnet synchronous motor
| | Inverter output frequency | 0.1...599 Hz
| | Maximum output frequency | 0.0001...0.5 kHz
| | Rated switching frequency | 4 kHz
| | Switching frequency | 2...12 kHz adjustable
4...12 kHz with derating factor
| | Security features | STO (Safe Torque Break) SIL 3
| | Discrete input logic | 16 preset speeds
| | Communication port protocol | Modbus serial
Ethernet
Modbus TCP
| | tab | Communication module Profibus DP V1 card slot A
Communication module Profinet card slot A
Communication module DeviceNet card slot A
Communication module Modbus TCP/EtherNet/IP card slot A
Communication module CANopen Daisy Chain RJ45 Card Slot A
Communication module CANopen SUB-D 9 card slot A
Communication module CANopen screw terminal strip card slot A
Digital and Input I/O Expansion Modules Card Slot A/Card Slot B
Relay Output Expansion Module Card Slot A/Card Slot B
Communication module Ethernet IP/Modbus TCP/MD-Link card slot A
Communication module BACnet MS/TP
Communication module Ethernet Powerlink
| | Supplemental informationOutput voltage | < = Supply voltage
| | Allowable temporary boost current | 1.1 x In 60 sec standard load
1.5 x In 60 sec reload
| | Motor slip compensation | The law of permanent magnet synchronous motor is not applicable
adjustable
Automatic regardless of load situation
Can be suppressed
| | Acceleration and deceleration tilt | Linearity can be monotonic from 0.01... 9999S
| | Braking to stop | DC injection is used
| | Type of protection | Safe torque off motor
Motor phase-off motor
Safe torque off drive
Overheated drive
Short-circuit protection drive
The motor is driven by a phase breaker
Overdrive drive
Control circuit on the brake drive
DC bus overvoltage drive
Output voltage overload drive
Line power overvoltage drive
Bus power out-of-phase drive
Bus-powered undervoltage drive
Overcurrent drive between the output phase and ground
Thermal protection motor
Thermal protection drive
| | Frequency resolution | Display unit
Analog inputs
| | Electrical connections | Detachable screw terminal 0.5...1.5 mm² AWG 20...AWG 16 control
Screw terminations 2.5...6 mm² AWG 14...AWG 10 motor
Screw terminations 2.5...6 mm² AWG 14...AWG 10 line side
| | Port type | RJ45 Ethernet/Modbus TCP on remote graphics terminals
RJ45 Modbus Serial in remote graphics terminal
| | Physical interfaces | 2-wire RS485 Modbus serial
| | Transfer frames | RTU Modbus Serial
| | Transmission rate | IP/Modbus TCP for 10/100 Mbit/s Ethernet
4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
| | Exchange mode | Half-duplex, full-duplex, auto-negotiated Ethernet/Modbus TCP
| | data format | 8 bits, configurable as even, odd, or no odd-even Modbus serial
| | Polarization mode | Impedance-free Modbus serial
| | Number of addresses | 1...247 Modbus serial
| | Access method | Slave (station) Modbus TCP
| | power supply | Internal power supply for reference potentiometer (1 to 10 kOhm) 10.5 V dc +/- 5 % <= 10 mA overload and short-circuit protection
External power supply for logic inputs 24 V dc 19...30 V <= 1.25 mA Overload and short-circuit protection
Internal power supply and STO function for logic inputs 24 V dc 21...27 V <= 200 mA Overload and short-circuit protection
| | Local signal indication | 3 LED local diagnostics
3 LED bi-color integrated communication status
4 LEDs to indicate the status of the communication module
1 LED red voltage status
| | width | 144 mm
| | height | 350 mm
| | depth | 203 mm
| | Product weight | 4.3 kg
| | The number of analog inputs | 3
| | Analog input type | Software - configurable voltages AI1, AI2, AI3 0...10 V DC 30 kOhm 12 bits
Software - Configurable currents AI1, AI2, AI3 0...20 mA/4...20 mA 250 Ω 12 bits
| | The number of discrete inputs | 8
| | Digital input type | Programmable DI1... DI6 24 V DC 3.5 kOhm
Programmable pulse inputs DI5, DI6 0...30 kHz 24 V DC
Safe torque interrupt STOA, STOB 24 V DC > 2.2 kOhm
| | Inputs are compatible | Class 1 PLC EN/IEC 61131-2 DI1... DI6 discrete inputs
Level 1 PLC IEC 65A-68 DI5, DI6 discrete inputs
Level 1 PLC EN/IEC 61131-2 STOA, STOB discrete inputs
| | Discrete input logic | Negative Logic (Leak) DI1... DI6 < 5 V > 11 V
Negative Logic (Leak) DI1... DI6 > 16 V < 10 V
Negative logic (drain) DI5, DI6 < 0.6 V > 2.5 V
Negative logic (drain) STOA, STOB < 5 V > 11 V
| | Number of analog outputs | 2
| | Analog output model | Software - configurable voltages AO1, AO2 0...10 V DC 470 Ω 10 bits
Software - configurable currents AO1, AO2 0...20 mA 10 bits
| | During sampling | 2 ms +/- 0.5 ms DI1... DI4 discrete inputs
5 ms +/- 1 ms DI5, DI6 discrete inputs
5 ms +/- 0.1 ms AI1, AI2, AI3 analog inputs
10 ms +/- 1 ms AO1 analog output
| | precision | +/- 0.6 % AI1, AI2, AI3 for temperature fluctuations of 60 °C Analog inputs
+/- 1 % AO1, AO2 for temperature fluctuations of 60 °C Analog output
| | Linearity error | Maximum +/- 0.15 % analogue input AI1, AI2, AI3
+/- 0.2 % analogue output AO1, AO2
| | Number of relay outputs | 3
| | Relay output type | Configurable relay logic R1 fault relay NO/NC 100000 cycles
Configurable relay logic R2 sequence relay NO 100000 times
Configurable relay logic R3 sequence relay NO 100000 times
| | Updated | 5 ms +/- 0.5 ms R1, R2, R3 relay outputs
| | Minimum switching current [Imin] | 5 mA 24 V DC R1, R2, R3 relay outputs
| | Maximum switching current | 3 A 250 V AC resistive (load) 1 R1, R2, R3 relay outputs
3 A 30 V DC resistive (load) 1 R1, R2, R3 relay outputs
2 A 250 V AC inductive load 0.4 7 ms R1, R2, R3 relay outputs
2 A 30 V DC inductive load 0.4 7 ms R1, R2, R3 relay outputs
| | isolation | between the power supply and the control terminals
| | Application-specific | Utilities
| | IP rating | IP21
| | Inverter application selection | Construction-HVAC centrifugal compressors
Food & Beverage Processing Equipment for other applications
Mining of mineral and metal wind turbines
Mining minerals and metals pumps
Oil & Gas Fans
Water & Wastewater Equipment for other applications
Construction-HVAC screw compressors
Food & Beverage Processing Pumps
Food & Beverage Processing Fans
Food and beverage processing automation
Oil & Gas Electric Submersible Pumps (ESP)
Oil & Gas Water Jet Pumps
Oil & Gas High efficiency fuel pumps
Oil & Gas Compressors for refining
Water & Wastewater Centrifugal pumps
Water & Wastewater Positive displacement pumps
Water & Wastewater Electric Submersible Pumps (ESP)
Water & Wastewater Progressive cavity pumps
Water & Wastewater Screw compressors
Water & Wastewater Screw compressors
Water & Wastewater Centrifugal compressors
Water and wastewater fans
Water and wastewater conveyors
Water & Wastewater Mixers
| | Drive power range AC-3 | 0.55...1 kW 200...240 V 3 phases
| | Motor starter type | Frequency converters
| | environmentInsulation resistance | > 1 MOhm grounded for 1 minute 500 V DC
| | Noise level | 54.5 dB 86/188/EEC
| | Power consumption W | 27 W naturally ventilated 200 V 4 kHz
28 W forced ventilation 200 V 4 kHz
| | Cooling air capacity | 38 m3/h
| | Operating position | +/- 10° vertically
| | THDI | < = 48 % full load IEC 61000-3-12
| | Electromagnetic compatibility | Resistance to conduction fluctuations caused by RF fields Level 3 IEC 61000-4-6
1.2/50 and 8/20 μs complexes (test) Level 3 IEC 61000-4-5
Fast transient resistance Level 4 IEC 61000-4-4
Electrostatic Discharge Immunity Level 3 IEC 61000-4-2
RF Electromagnetic Field Radiated Immunity Test Level 3 IEC 61000-4-3
| | Pollution level | 2 EN/IEC 61800-5-1
| | Vibration-resistant | Crest to crest 1.5 mm 2...13 Hz IEC 60068-2-6
1 gn 13...200 Hz IEC 60068-2-6
| | Impact-resistant | 15 gn 11 ms IEC 60068-2-27
| | relative humidity | 5...95 % non-condensing IEC 60068-2-3
| | Ambient temperature | -15...50 °C without degrading
50...60 °C with derating factor
| | Storage ambient temperature | -40...70 °C
| | Working altitude | 1000...4800 m current derating 1%/100m
< = 1000 m without degrading
| | Environmental characteristics | Chemical Contamination Resistance Class 3C3 EN/IEC 60721-3-3
Dirt Pollution Resistance Class 3S3 EN/IEC 60721-3-3
| | standard | EN/IEC 61800-3
EN/IEC 61800-3 Environment 1 Classification C2
EN/IEC 61800-3 Environmental 2 Classification C3
UL 508C
EN/IEC 61800-5-1
IEC 61000-3-12
IEC 60721-3
IEC 61508
IEC 13849-1
| | Product Certification | ATEX INERIS
DNV-GL
CSA
REACH
UL
TÜV
ATEX zone 2/22
| | logotype | CE
|
|
More on that
|
Schneider_RETMKITMIDM_Digital Power Meter LCD display
About RETMKITMIDM: Schneider Electric Digital Power Meter, PM5000 Series, 3 Phase, LCD Display
Schneider/Schneider _RETMKITMIDM
Model features introduced
SchneiderElectric retrofit metering kit
A series of SchneiderElec ...
|
|
Schneider frequency inverters ATV610D55N4 16 preset speeds
Introduction: ATV610 inverter is suitable for 380-415V three-phase asynchronous motors with a power range of 0.75 to 160kW. It can be widely used in standard load control systems. Comply with IEC/EN 61800-3, IEC/EN 61000-4, IEC/EN60721-3, IEC/EN 61800-5-1 and other international ...
|
|
Schneider_ATS01N106FT_ soft-start 6 A 3-phase 2.2kW
ATS01N106FT Introduction: Schneider Electric ATS01 Series 6 A 3-phase soft starter ATS01N106FT, IP20, 2.2 kW, 110 → 480 V
Schneider/Schneider_ATS01N106FT
Model features introduced
Altistart soft start
Can be combined with single phase or ...
|
|
Schneider frequency inverter ATV610D15N4 weighs 7.2 kg
Introduction: ATV610 inverter is suitable for 380-415V three-phase asynchronous motors with a power range of 0.75 to 160kW. It can be widely used in standard load control systems. Comply with IEC/EN 61800-3, IEC/EN 61000-4, IEC/EN60721-3, IEC/EN 61800-5-1 and other international ...
|
|
Schneider inverter ATV310HU15N4A 1.5kw
Introduction: ATV310A universal inverter has built-in Modbus communication protocol; Plug and play, fast start; Short menu design, new code display; Compact structure, small size, support side-by-side installation; Strong temperature resistance, can be used in -10C-55°C without degrading; Strengthened coatings, innovative air paths ...
|
|
Schneider inverter ATV610D30N4 26.1 kg
Introduction: ATV610 inverter is suitable for 380-415V three-phase asynchronous motors with a power range of 0.75 to 160kW. It can be widely used in standard load control systems. Comply with IEC/EN 61800-3, IEC/EN 61000-4, IEC/EN60721-3, IEC/EN 61800-5-1 and other international ...
|
|
Schneider/Schneider _ATS48D75Q_ soft-start controller with 6 thyristor transistors
ATS48D75Q Introduction: Schneider Electric ATS48 Series 75 A 3-phase soft starter ATS48D75Q, IP20, 37 kW, 230 → 415 V
Schneider/Schneider_ATS48D75Q
Model features introduced
AltistartATS48
Altistart48 Soft Start ...
|
|
Schneider inverter ATV212HD11N4 11kw
Introduction: Schneider inverter ATV212HD11N4 built-in Modubs and CANopen protocols, providing CANopen daisy chain, Profibus DP, DeviceNet; Brand new user interface with support for Chinese operation panel; Provide simple and multi-functional downloader, convenient parameter ...
|
|
Schneider inverter ATV610U75N4 7.5kW/10HP
Introduction: ATV610 inverter is suitable for 380-415V three-phase asynchronous motors with a power range of 0.75 to 160kW. It can be widely used in standard load control systems. Comply with IEC/EN 61800-3, IEC/EN 61000-4, IEC/EN60721-3, IEC/EN 61800-5-1 and other international ...
|
|
Schneider inverter ATV12H055M2 0.55kW
Introduction: ATV12 Schneider inverters are used in three-phase asynchronous motors with a power range of 0.18kW to 4kW. The ATV12 Schneider inverter is characterized by its easy installation (based on the plug-and-play principle), compact size, integrated multi-function and optional base version, making it particularly suitable for simple industrial ...
|
|
Schneider _VW3M9107_ servo drive current controller
VW3M9107 Introduction: Schneider Electric Current Controller, Tracking, Manual, Positioning, Speed Controller Servo Control VW3M9107
Schneider/Schneider_VW3M9107
Model features introduced
LEXIUM32I connection module
Connectivity modules and communication ...
|
|
Schneider_Schneider Electric Altistart soft start with soft stop – 400V
About Schneider Electric: RS Components
Schneider_Schneider Electric
Model features introduced
Altistart soft start with soft stop – 400V
Three-phase input controllable deceleration
All suppliers of 76 Technology have been strictly audited ...
|
|
Schneider _ATS01N222RT_ soft-start 440 → 480 V 22 A 3-phase
ATS01N222RT Introduction: Schneider Electric ATS01 Series 22 A 3-phase soft-start ATS01N222RT, IP20, 440 → 480 VAC
Schneider/Schneider _ATS01N222RT
Model features introduced
Altistart soft start
Available with single-phase or three-phase ...
|
|
Schneider inverter ATV312HU11M2 1.1KW
Introduction:ATV312 series general-purpose three-phase squirrel cage asynchronous motor inverter protection grade ATV... The M3X series is IP20 and has no cover on the upper part of the cover; ATV... The upper part of the M2 and N4 series is IP31 and IP41, and the connection terminal is IP21
...
|
|
Schneider _GBK0800803C_ servo drive and control transmission kit
GBK0800803C Introduction: Schneider Electric Connectors GBK0800803C, 80mm long, 80mm wide, 31.2mm deep
Schneider/Schneider _GBK0800803C
Model features introduced
BCH2 gearbox kit
SchneiderElectricBCH2 Servo Motor Variable Speed ...
|
|
Schneider _VW3M9101_ servo drive and control connection module
VW3M9101 Introduction: Schneider Electric Current Controller, Tracking, Manual, Positioning, Speed Controller Servo Control VW3M9101
Schneider/Schneider _VW3M9101
Model features introduced
LEXIUM32I connection module
Connectivity modules and communication ...
|
|
Schneider_VW3M9207 Speed Controllers Servo controlled
VW3M9207 Introduction: Schneider Electric Current Controller, Tracking, Manual, Positioning, Speed Controller, Servo Control, VW3M9207
Schneider/Schneider _VW3M9207
Model features introduced
LEXIUM32I connection module
Connectivity modules and communication ...
|
|
Schneider _ATS01N112FT_ soft-start 5.5 kW 12 A 3-phase
ATS01N112FT Introduction: Schneider Electric ATS01 Series 12 A 3-phase soft starter ATS01N112FT, IP20, 5.5 kW, 110 → 480 V
Schneider/Schneider _ATS01N112FT
Model features introduced
Altistart soft start
Ultra-miniature, ...
|
|
Schneider_ATS48D17Q_ soft-start 17 A 3-phase 7.5 kW
ATS48D17Q Introduction: Schneider Electric ATS48 Series 17 A 3-phase soft starter ATS48D17Q, IP20, 7.5 kW, 230 → 415 V
Schneider/Schneider _ATS48D17Q
Model features introduced
AltistartATS48
Altistart48 Soft Start ...
|
|
Schneider _ATS01N212QN_ soft-start 380 → 415 V
ATS01N212QN Introduction: Schneider Electric ATS01 Series 12 A 3-phase soft starter ATS01N212QN, IP20, 5.5 kW, 380 → 415 V
Schneider/Schneider _ATS01N212QN
Model features introduced
Altistart soft start with soft stop ...
|
|