5SY4220-7 Introduction: Siemens MCB Miniature Circuit Breaker, 2-Pole, 20 A, Type C Trip Characteristics
Germany Siemens/Siemens 5SY4220-7 picture display

Model features introduced
Automatic cut-out, 5SY4 series, 10kA, type B, type C and type D characteristics
Siemens miniature circuit breakers offer the highest quality and reliability. The excellent technical characteristics of the equipment mean that you are always safe and reliable. In addition to this, you can also benefit from innovative mounting options that allow for quick and easy installation. Siemens' miniature circuit breakers can be combined with a variety of complementary components as required, such as control current switches, fault signal contacts, shunt releases, undervoltage releases, remote operating mechanisms or RCCB units to protect personnel and prevent fires.
Features and Benefits:
Automatic cut-out, 1-, 2-, 3- and 4-pole DIN rail assemblies for the industrial, functional and residential construction industries support quick and easy removal from components
standard
IEC60898 - for low-voltage circuit breakers, suitable for household and similar installations. Known as miniature circuit breakers (MCBs) in the United Kingdom.
Q: What are the differences between trip curves B, C, and D?
A: Curve B: Trip: 3 to 5 times the rated current. Application: Protection of generators, personnel, very long cable curves C: Tripping: 5 to 10 times the rated current Application: Protection circuits and general application curves D: Tripping: 10 to 14 times the rated current Application: Protecting high surge circuits, welders, transformers and electric motors
Voltage Rating: | 230V/400V AC, 250V/440V AC, 60V DC/pole | Suppression Rating: | 10kA | Installation Depth: | 70mm |
SiemensRCD、RCBO、RCCB和MCB
The Type B feature provides an instantaneous short-circuit response level of 3-5 times the normal rated current, making it suitable for circuits with moderate inrush currents, such as incandescent lamps, heated loads, and most residential/small building protection applications. The Type C feature provides a short-circuit response of 5-10 times the normal rated current, making it suitable for higher inrush current circuits, such as motor control and fluorescent lamp installations in factories where noise-induced tripping may occur if a faster type is used. The D-type feature is designed for high inrush current loads. Magnetic trip point - 10 to 20 times rated. Thermal trigger point - 1.13 to 1.45 rated protector. The AC type feature ensures disconnection when a sinusoidal, direct current is applied quickly or slowly increased.
Model parameters are introduced
attribute | numeric value | range | Sentron | series | 5SY4 | Number of poles | 2 | Current rating | 20A | Trip characteristics | Type C | Rated AC voltage | 400V | Breaking capacity | 10kA | length | 90mm | width | 36mm | depth | 76mm |
The above content is about the product introduction of Germany Siemens / Siemens 5SY4220-7, if you have any questions or product needs, please feel free to communicate with our customer service, all products of 76 technology are genuine, false one pays ten, are manufacturers or selected first-class agent sources, the quotation is real, the price is beautiful.
Survive by quality, develop by reputation, eternity by service, give us a chance, and give you a surprise. |
More on that
|
Germany Siemens/Siemens 5SJ65327CC20
5SJ65327CC20 Introduction: Siemens MCB miniature circuit breaker, 1 + N pole, 32 A, type C trip characteristics
German Siemens/Siemens 5SJ65327CC20 picture display
Model features introduced
5SJ6MCB series - 6kA, B type and C type characteristics
Line Protection Switches ...
|
|
Germany Siemens/Siemens 5SY4132-8
5SY4132-8 Introduction: Siemens MCB miniature circuit breaker, 1 pole, 32 A, type D trip characteristics
German Siemens/Siemens 5SY4132-8 picture display
Model features introduced
Automatic cut-out, 5SY4 series, 10kA, type B, type C and type D characteristics
Siemens Micro ...
|
|
Germany Siemens/Siemens 3RV1021-1JA10 motor protection circuit breaker
3RV1021-1JA10 Introduction: Siemens Motor Protection Circuit Breaker, 3RV1 Series, Current Range 7 → 10 A 3 Pole, 100 kA Disconnect Capability
Germany Siemens/Siemens 3RV1021-1JA10 picture show
Model features introduced
Three-pole circuit breaker-3RV10 series ...
|
|
Germany Siemens/Siemens 3SB3400-1QB Illuminated Button Holder Lighting Block
3SB3400-1QB Introduction: Siemens Illuminated Button Holder, Siemens 3SB3 Series, Lighting Block, Red, 110 V, LED, Screw Termination
German Siemens/Siemens 3SB3400-1QB picture show
Model features introduced
Integrated lampholder
Integrated LED, optional working ...
|
|
Germany Siemens/Siemens 3RB2133-4UB0
3RB2133-4UB0 Introduction: Siemens Thermal Overload Relays 3RB Series, 12.5 → 50 A, 22 kW, Contact Rating 80 A, Contact Voltage Rating 690 V AC
German Siemens/Siemens 3RB2133-4UB0 picture display
Model features introduced
3RB21 Series ...
|
|
Germany Siemens/Siemens 3RU2116-0KB0 Thermal Overload Relay 0.37 kW 0.9 → 1.25 A
3RU2116-0KB0 Introduction: Siemens Thermal Overload Relay 3RU Series, 0.9 → 1.25 A, 0.37 kW, Contact Current Rating 1.25 A
German Siemens/Siemens 3RU2116-0KB0 picture show
Model features introduced
Overload Relay-3RU Series
Switch position ...
|
|
German Siemens/Siemens 3SB3902-1MF cross-reference 3SB3/SIRIUSACT
3SB3902-1MF Introduction: Siemens Legend Board, Legend Board, For Use With 3SB3 Series
German Siemens/Siemens 3SB3902-1MF picture display
Model features introduced
Legend board
The back of the label board has an adhesive layer (black with white callings). The label board size is 22 ...
|
|
Germany Siemens/Siemens 5SY4316-8
5SY4316-8 Introduction: Siemens MCB miniature circuit breaker, 3-pole, 16 A, type D trip characteristics
German Siemens/Siemens 5SY4316-8 picture display
Model features introduced
Automatic cut-out, 5SY4 series, 10kA, type B, type C and type D characteristics
Siemens Micro ...
|
|
Germany Siemens/Siemens 5SJ66327CC20 miniature circuit breaker 3+N pole
5SJ66327CC20 Introduction: Siemens MCB miniature circuit breaker, 3 + N pole, 27 A, type C trip characteristics
German Siemens/Siemens 5SJ66327CC20 picture display
Model features introduced
5SJ6MCB series - 6kA, B type and C type characteristics
Line Protection Switches ...
|
|
Germany Siemens/Siemens 3RU2126-4FB0
3RU2126-4FB0 Introduction: Siemens Thermal Overload Relays 3RU Series, 34 → 40 A, 18.5 kW, Contact Rating 40 A, Contact Voltage Rating 690 V AC
German Siemens/Siemens 3RU2126-4FB0 picture show
Model features introduced
Overload Relay ...
|
|
Germany Siemens/Siemens 3RV60214EA15 cage spring clamp technology 3 poles
3RV60214EA15 Introduction: Siemens MCB, 3RV6 series, current range 27 → 32 A 3 poles, 55 KA disconnect capacity, rated voltage 690 V AC
Germany Siemens/Siemens 3RV60214EA15 picture display
Model features introduced
Circuit breaker 3 pole-3R...
|
|
Germany Siemens/Siemens 3SE5000-0AV03 Horizontal Actuator Limit Switch
3SE5000-0AV03 Introduction: Siemens 3SE5000-0AV03 actuator head, horizontal actuator, used with 3SE5 limit switches
German Siemens/Siemens 3SE5000-0AV03 picture show
Model features introduced
3SE5 Series, Standard
SIRIUS3SE5 position switch ...
|
|
Germany Siemens/Siemens 3RB3026-1QE0
3RB3026-1QE0 Introduction: Siemens Solid State Overload Relay 3RB Series, 6 → 25 A, 11 kW, Contact Rated Current 25 A, Contact Rated Voltage 690 V AC
German Siemens/Siemens 3RB3026-1QE0 picture display
Model features introduced
Solid state overload relay ...
|
|
Germany Siemens/Siemens 3VU16400LS00
3VU16400LS00 Introduction: Siemens MCB miniature circuit breaker, 1 pole, 63 A
German Siemens/Siemens 3VU16400LS00 picture show
Model features introduced
3VU series circuit breaker
Motor protection circuit breaker for protection against motor overload, single-phase and ...
|
|
Germany Siemens/Siemens 5SY4510-7
5SY4510-7 Introduction: Siemens MCB Miniature Circuit Breaker, 1 + N Pole, 10 A, Type C Trip Characteristics
German Siemens/Siemens 5SY4510-7 picture display
Model features introduced
Automatic cut-out, 5SY4 series, 10kA, type B, type C and type D characteristics
Siemen ...
|
|
Germany Siemens/Siemens 5SY4510-6
5SY4510-6 Introduction: Siemens MCB Miniature Circuit Breaker, 1 + N Pole, 10 A, Type B Trip Characteristics
Germany Siemens/Siemens 5SY4510-6 picture display
Model features introduced
Automatic cut-out, 5SY4 series, 10kA, type B, type C and type D characteristics
Siemen ...
|
|
Germany Siemens/Siemens 5SJ62167CC20
5SJ62167CC20 Introduction: Siemens MCB miniature circuit breaker, 2 pole, 16 A, type C trip characteristics
Germany Siemens/Siemens 5SJ62167CC20 picture display
Model features introduced
5SJ6MCB series - 6kA, B type and C type characteristics
Line protection switch with ...
|
|
Germany Siemens/Siemens 3SB3902-1ED Legend board The label board has an adhesive layer on the back
3SB3902-1ED Introduction: Siemens Legend Board, Backplane, For Use With 3SB3 Series
German Siemens/Siemens 3SB3902-1ED picture show
Model features introduced
Legend board
The back of the label board has an adhesive layer (black with white callings). The label board size is 22mm ...
|
|
Germany Siemens/Siemens 3SB3400-1A Button holder with light Screw ends
3SB3400-1A Introduction: Siemens Illuminated Button Holder, Siemens 3SB3 Series, Lighting Block, BA9S Bulb, Screw Connector
German Siemens/Siemens 3SB3400-1A picture show
Model features introduced
lamp holder
Equipped with screw terminals, cage spring terminals ...
|
|
Germany Siemens/Siemens 3RU1116-1FC1 Thermal Overload Relay Voltage 690 V
3RU1116-1FC1 Introduction: Siemens Thermal Overload Relay 3RU Series, 3.5 → 5 A, 1.5 kW, Contact Rated Current 5 A, Contact Rated Voltage 690 V AC
German Siemens/Siemens 3RU1116-1FC1 picture show
Model features introduced
Overload Relay-3 ...
|
|